RPH isotope and class index

Classifier for 279 radiopharmaceutical utilities: use-case classes, organs and systems, isotope families, workflow, and related API, instrumental and medical-device layers. Universal navigation across FUZKK radiopharmaceutical and related utilities: from a medical class and organ system to an isotope, workflow stage and a specific utility. The layers are not mutually exclusive: API describes calculation or rule-based logic; instrumental covers laboratory and imaging measurement outputs; medical devices covers equipment state, software lifecycle, safety and radiation-physics context.

279
RPH and related utilities
11
use-case classes
10
organs and systems
10
isotope families
7
workflow stages

Use-case classes

The primary map. Each class package groups a medically coherent use case. Utilities are separated into API, instrumental and medical-device layers.

Tc-99m renal and nephrourology 17

Renal radiopharmaceuticals and calculation workflows: MAG3, DTPA, DMSA, glucoheptonate, generator Tc-99m, dynamic renography, GFR/ERPF and dosimetry.

Open package

API / calculation and rule-based 11

Reducing Agent Stoichiometry Calculator API / calculation and rule-basedTc-99m
What it does

Utility calculates the optimal volume of Stannous Chloride (SnCl2) solution: Based on ligand mass and Tc-99m activity Considering excess factor (to compensate for oxidation) With checks for toxicity and colloid formation risk

Why it is needed

Supports a controlled renal workflow from Tc-99m kit and generator quality through renal-function calculation and patient dosimetry.

Where and when to use it

during Tc-99m renal kit release, before dynamic imaging, during quantitative interpretation and when reviewing questionable renogram curves. Medical use: renal and urinary, hepatobiliary and GI, bone and musculoskeletal. Workflow stages: synthesis, labelling and kit reconstitution, product release QC, imaging QC and quantitative interpretation.

Input fields

KitName, LigandMassMg, LigandMolecularWeight, Tc99mActivityGBq, SnCl2ConcentrationMgPerML, ExcessFactor, VolumeToReconstituteML

Open utility

Related utilities
Stannous Chloride Solution Stability Checker API / calculation and rule-basedTc-99m
What it does

Utility checks the quality of Stannous Chloride (SnCl2) solution: Sn(II) concentration (degradation ≤10%) pH of the medium (hydrolysis prevention) Visual inspection (no precipitate)

Why it is needed

Supports a controlled renal workflow from Tc-99m kit and generator quality through renal-function calculation and patient dosimetry.

Where and when to use it

during Tc-99m renal kit release, before dynamic imaging, during quantitative interpretation and when reviewing questionable renogram curves. Medical use: renal and urinary. Workflow stages: synthesis, labelling and kit reconstitution, product release QC, imaging QC and quantitative interpretation.

Input fields

SolutionBatchID, PreparationDate, InitialConcentrationMgPerML, MeasuredConcentrationMgPerML, PHValue, HasPrecipitate, StorageCondition, DaysSincePreparation, TemperatureC

Open utility

Related utilities
Stannous Ion Concentration QC API / calculation and rule-basedTc-99m
What it does

Utility controls key component of radiopharmaceuticals: Stannous ion (Sn2+) concentration Optical density (spectrophotometry) Sn/Tc ratio

Why it is needed

Supports a controlled renal workflow from Tc-99m kit and generator quality through renal-function calculation and patient dosimetry.

Where and when to use it

during Tc-99m renal kit release, before dynamic imaging, during quantitative interpretation and when reviewing questionable renogram curves. Medical use: renal and urinary, hepatobiliary and GI, cardiovascular. Workflow stages: synthesis, labelling and kit reconstitution, generators and isotope purity, imaging QC and quantitative interpretation.

Input fields

BatchNumber, ProductName, Sn2_Conc_ug_ml, Absorbance, Target_Activity_MBq, Volume_ml, Min_Sn, Max_Sn

Open utility

Related utilities
Tc-99m DMSA(III) Radiochemical Purity Checker API / calculation and rule-basedTc-99m
What it does

Utility checks critical parameters of Tc-99m DMSA(III): Radiochemical purity (≥90-95%) Free pertechnetate (≤5%) Reduced/hydrolyzed technetium (≤5%)

Why it is needed

Supports a controlled renal workflow from Tc-99m kit and generator quality through renal-function calculation and patient dosimetry.

Where and when to use it

during Tc-99m renal kit release, before dynamic imaging, during quantitative interpretation and when reviewing questionable renogram curves. Medical use: renal and urinary, hepatobiliary and GI, endocrine, thyroid and NET. Workflow stages: synthesis, labelling and kit reconstitution, product release QC, imaging QC and quantitative interpretation.

Input fields

BatchNumber, RadiochemicalPurityPercent, FreePertechnetatePercent, ReducedHydrolyzedTechnetiumPercent, AluminumOxidePPM, pH, EndotoxinsEU_per_mL, SterilityTest, HeavyMetalsPPM, HoursSincePreparation

Open utility

Related utilities
Tc-99m DTPA Stability And Transchelation Checker API / calculation and rule-basedTc-99m
What it does

Utility checks critical parameters of Tc-99m DTPA: Radiochemical purity (≥95%) Free pertechnetate (≤5%) Reduced/hydrolyzed technetium (≤5%)

Why it is needed

Supports a controlled renal workflow from Tc-99m kit and generator quality through renal-function calculation and patient dosimetry.

Where and when to use it

during Tc-99m renal kit release, before dynamic imaging, during quantitative interpretation and when reviewing questionable renogram curves. Medical use: renal and urinary, hepatobiliary and GI, brain and CNS, endocrine, thyroid and NET, bone and musculoskeletal. Workflow stages: synthesis, labelling and kit reconstitution, product release QC, imaging QC and quantitative interpretation.

Input fields

BatchNumber, RadiochemicalPurityPercent, FreePertechnetatePercent, ReducedHydrolyzedTechnetiumPercent, TranschelationPercent, AluminumOxidePPM, pH, EndotoxinsEU_per_mL, SterilityTest, HeavyMetalsPPM

Open utility

Related utilities
Tc-99m Glucoheptonate Quality Checker API / calculation and rule-basedTc-99m
What it does

Utility checks critical parameters of Tc-99m Glucoheptonate (GH): Radiochemical purity (≥95%) Free pertechnetate (≤5%) Reduced/hydrolyzed technetium (≤5%)

Why it is needed

Supports a controlled renal workflow from Tc-99m kit and generator quality through renal-function calculation and patient dosimetry.

Where and when to use it

during Tc-99m renal kit release, before dynamic imaging, during quantitative interpretation and when reviewing questionable renogram curves. Medical use: renal and urinary, hepatobiliary and GI, brain and CNS, endocrine, thyroid and NET, oncology and theranostics. Workflow stages: synthesis, labelling and kit reconstitution, product release QC, dosimetry and therapy planning.

Input fields

BatchNumber, RadiochemicalPurityPercent, FreePertechnetatePercent, ReducedHydrolyzedTechnetiumPercent, AluminumOxidePPM, pH, EndotoxinsEU_per_mL, SterilityTest, HeavyMetalsPPM, HoursSincePreparation

Open utility

Related utilities
Tc-99m Labeling Reaction pH Optimization Tool API / calculation and rule-basedTc-99m
What it does

Utility calculates the required buffer volume to achieve target pH: Considers drug type (DMSA, MAG3, HMPAO...) Calculates buffer volume without excessive dilution Assesses complex instability risk

Why it is needed

Supports a controlled renal workflow from Tc-99m kit and generator quality through renal-function calculation and patient dosimetry.

Where and when to use it

during Tc-99m renal kit release, before dynamic imaging, during quantitative interpretation and when reviewing questionable renogram curves. Medical use: renal and urinary. Workflow stages: synthesis, labelling and kit reconstitution, generators and isotope purity, imaging QC and quantitative interpretation.

Input fields

KitName, EluateVolumeML, EluatePH, TargetPH, LigandBufferCapacity, BufferType, BufferConcentrationM, BufferPH

Open utility

Related utilities
Tc-99m MAG3 Labeling Efficiency Analyzer API / calculation and rule-basedTc-99m
What it does

Utility controls quality of renal scintigraphy agent: Radiochemical purity (>90%) Free pertechnetate (<5%) Hydrolyzed/colloidal Tc (<5%)

Why it is needed

Supports a controlled renal workflow from Tc-99m kit and generator quality through renal-function calculation and patient dosimetry.

Where and when to use it

during Tc-99m renal kit release, before dynamic imaging, during quantitative interpretation and when reviewing questionable renogram curves. Medical use: renal and urinary, hepatobiliary and GI, endocrine, thyroid and NET. Workflow stages: synthesis, labelling and kit reconstitution, product release QC, generators and isotope purity.

Input fields

BatchNumber, ProductName, Complex_Percent, Free_Tc_Percent, Hydrolyzed_Percent, pH, Incubation_Min, Activity_MBq, Min_RCP, Max_Free

Open utility

Related utilities
Tc-99m Mertiatide (MAG3) Kinetic Stability Checker API / calculation and rule-basedTc-99m
What it does

Utility evaluates MAG3 complex stability over time: Radiochemical purity (RCP) drop over 4 and 8 hours Transchelation rate (transfer to proteins) Impact of storage conditions (temperature, light)

Why it is needed

Supports a controlled renal workflow from Tc-99m kit and generator quality through renal-function calculation and patient dosimetry.

Where and when to use it

during Tc-99m renal kit release, before dynamic imaging, during quantitative interpretation and when reviewing questionable renogram curves. Medical use: renal and urinary, hepatobiliary and GI. Workflow stages: synthesis, labelling and kit reconstitution, product release QC, imaging QC and quantitative interpretation.

Input fields

BatchNumber, InitialRCP_Percent, RCP_After4Hours, RCP_After8Hours, TranschelationPercent_4h, TranschelationPercent_8h, StorageTemperatureC, LightProtected, pH_At_T0

Open utility

Related utilities
Tc99m MAG3 Quality Checker API / calculation and rule-basedTc-99m
What it does

Utility checks critical parameters of Tc-99m MAG3: Radiochemical purity (≥90%) Free pertechnetate (≤5%) Colloidal technetium (≤5%)

Why it is needed

Supports a controlled renal workflow from Tc-99m kit and generator quality through renal-function calculation and patient dosimetry.

Where and when to use it

during Tc-99m renal kit release, before dynamic imaging, during quantitative interpretation and when reviewing questionable renogram curves. Medical use: renal and urinary, hepatobiliary and GI, endocrine, thyroid and NET. Workflow stages: synthesis, labelling and kit reconstitution, product release QC, generators and isotope purity.

Input fields

BatchNumber, TotalActivityMBq, RadiochemicalPurityPercent, FreePertechnetatePercent, ReducedHydrolyzedTcPercent, pH, EndotoxinsEU, SterilityTest, ReactionTimeMin, CoolingTimeMin

Open utility

Related utilities
Technetium99m Glucoheptonate Checker API / calculation and rule-basedTc-99m
What it does

Utility checks critical parameters of Tc-99m Glucoheptonate: Radiochemical purity (≥90%) Free pertechnetate (≤5%) Colloidal technetium (≤5%)

Why it is needed

Supports a controlled renal workflow from Tc-99m kit and generator quality through renal-function calculation and patient dosimetry.

Where and when to use it

during Tc-99m renal kit release, before dynamic imaging, during quantitative interpretation and when reviewing questionable renogram curves. Medical use: renal and urinary, hepatobiliary and GI, brain and CNS, endocrine, thyroid and NET, oncology and theranostics. Workflow stages: synthesis, labelling and kit reconstitution, product release QC, generators and isotope purity.

Input fields

BatchNumber, TotalActivityMBq, RadiochemicalPurityPercent, FreePertechnetatePercent, ReducedHydrolyzedTcPercent, pH, EndotoxinsEU, SterilityTest, TimeSinceReconstitutionMin, ProductType

Open utility

Related utilities

Instrumental 3

Renal Kidney Uptake Calculation Helper InstrumentalTc-99m
What it does

Utility calculates quantitative renal function parameters: Left and right kidney uptake percentage Total Uptake Asymmetry Index

Why it is needed

Supports a controlled renal workflow from Tc-99m kit and generator quality through renal-function calculation and patient dosimetry.

Where and when to use it

during Tc-99m renal kit release, before dynamic imaging, during quantitative interpretation and when reviewing questionable renogram curves. Medical use: renal and urinary. Workflow stages: imaging QC and quantitative interpretation, stability, storage, decay and waste, instruments, devices and radiation safety.

Input fields

BatchNumber, ProductName, Left_Counts, Right_Counts, BG_Counts, Dose_MBq, Calib_Factor, Atten_Coeff, Left_Depth_cm, Right_Depth_cm

Open utility

Related utilities
Tc-99m Generator Breakthrough Mo-99 Checker InstrumentalTc-99m
What it does

Utility checks critical parameters of Tc-99m generator eluate: Mo-99 breakthrough (<0.15 kBq per 1 MBq Tc-99m) — CRITICAL! Aluminum oxide (<10 ppm) pH (4.5-7.5)

Why it is needed

Supports a controlled renal workflow from Tc-99m kit and generator quality through renal-function calculation and patient dosimetry.

Where and when to use it

during Tc-99m renal kit release, before dynamic imaging, during quantitative interpretation and when reviewing questionable renogram curves. Medical use: renal and urinary, pulmonary and ventilation, blood, cells and marrow. Workflow stages: synthesis, labelling and kit reconstitution, product release QC, generators and isotope purity.

Input fields

BatchNumber, Tc99mActivityMBq, Mo99ActivityKBq, AluminumOxidePPM, pH, EndotoxinsEU_per_mL, SterilityTest, GeneratorAgeDays, EluateVolumeML

Open utility

Related utilities
Tc-99m Waste Decay Storage Manager InstrumentalTc-99m
What it does

Utility calculates waste hold time until background level: Current residual activity Number of elapsed half-lives Exact Release Date for disposal

Why it is needed

Supports a controlled renal workflow from Tc-99m kit and generator quality through renal-function calculation and patient dosimetry.

Where and when to use it

during Tc-99m renal kit release, before dynamic imaging, during quantitative interpretation and when reviewing questionable renogram curves. Medical use: renal and urinary. Workflow stages: synthesis, labelling and kit reconstitution, product release QC, generators and isotope purity.

Input fields

WasteContainerID, GenerationDate, InitialActivityMBq, BackgroundLevelMBq, WasteType, HalfLifeHours, RequiredHalfLives

Open utility

Related utilities

Medical devices 3

Bladder Voiding Efficiency Analyzer Medical devicesTc-99m
What it does

Utility calculates the percentage of activity evacuation from the bladder: Voiding efficiency (normal >90%) Residual activity percent (normal <10%) Correction for background and Tc-99m radioactive decay

Why it is needed

Supports a controlled renal workflow from Tc-99m kit and generator quality through renal-function calculation and patient dosimetry.

Where and when to use it

during Tc-99m renal kit release, before dynamic imaging, during quantitative interpretation and when reviewing questionable renogram curves. Medical use: renal and urinary, brain and CNS. Workflow stages: imaging QC and quantitative interpretation, stability, storage, decay and waste.

Input fields

PatientID, StudyDate, PreVoidCounts, PostVoidCounts, BackgroundCounts, AcquisitionTimePreSec, AcquisitionTimePostSec, DecayCorrectionFactor, ResidualVolumeML

Open utility

Related utilities
Renal Plasma Clearance Estimator Medical devicesTc-99m
What it does

Utility calculates Glomerular Filtration Rate (GFR) or Effective Renal Plasma Flow (ERPF): Based on single-sample blood analysis method Considering injected activity and plasma concentration With normalization to Body Surface Area (BSA)

Why it is needed

Supports a controlled renal workflow from Tc-99m kit and generator quality through renal-function calculation and patient dosimetry.

Where and when to use it

during Tc-99m renal kit release, before dynamic imaging, during quantitative interpretation and when reviewing questionable renogram curves. Medical use: renal and urinary. Workflow stages: imaging QC and quantitative interpretation.

Input fields

PatientID, StudyDate, InjectedActivityMBq, PreInjectionSampleCounts, PostInjectionSampleCounts, BloodSampleCountsPerML, TimePostInjectionMin, PatientWeightKg, PatientHeightCm, PatientAge

Open utility

Related utilities
Tc-99m Renal Dosimetry Calculator Medical devicesTc-99m
What it does

Utility calculates absorbed doses based on MIRD model: Kidney Absorbed Dose Bladder Wall Dose Effective Whole Body Dose

Why it is needed

Supports a controlled renal workflow from Tc-99m kit and generator quality through renal-function calculation and patient dosimetry.

Where and when to use it

during Tc-99m renal kit release, before dynamic imaging, during quantitative interpretation and when reviewing questionable renogram curves. Medical use: renal and urinary. Workflow stages: dosimetry and therapy planning, imaging QC and quantitative interpretation, instruments, devices and radiation safety.

Input fields

PatientID, Radiopharmaceutical, InjectedActivityMBq, PatientWeightKg, PatientAgeYears, BiologicalHalfLifeHours, BladderVoidingIntervalHours, KidneyMassGrams

Open utility

Related utilities
Tc-99m MAA, V/Q and radioembolization 18

Macroaggregated albumin: particle size and count, radiochemical purity, resuspension, lung perfusion, lung shunt and pre-therapy Y-90 planning.

Open package

API / calculation and rule-based 4

Tc-99m DTPA Aerosol Quality Checker API / calculation and rule-basedTc-99m
What it does

Utility performs: Control of radiochemical purity, free Tc-99m, aerodynamic size, activity and use time of the aerosol. input.csv structure and numeric-value validation LabWare-compatible output.json generation

Why it is needed

Connects MAA product quality, lung perfusion, shunt calculation and radioembolization planning without separating release checks from quantitative interpretation.

Where and when to use it

during MAA preparation, V/Q studies, lung-shunt assessment and radioembolization planning. Medical use: renal and urinary, pulmonary and ventilation. Workflow stages: product release QC, imaging QC and quantitative interpretation.

Input fields

BatchNumber, RadiochemicalPurityPercent, FreePertechnetatePercent, MMADUm, GeometricStandardDeviation, ActivityMBq, TimeSincePreparationMin, pH

Open utility

Related utilities
Tc-99m MAA Quality Checker API / calculation and rule-basedTc-99m
What it does

Utility performs: Comprehensive batch review of Tc-99m macroaggregated albumin before lung-perfusion scintigraphy or MAA-based radioembolization planning. input.csv structure and numeric-value validation LabWare-compatible output.json generation

Why it is needed

Connects MAA product quality, lung perfusion, shunt calculation and radioembolization planning without separating release checks from quantitative interpretation.

Where and when to use it

during MAA preparation, V/Q studies, lung-shunt assessment and radioembolization planning. Medical use: pulmonary and ventilation, oncology and theranostics. Workflow stages: product release QC, dosimetry and therapy planning, imaging QC and quantitative interpretation.

Input fields

BatchNumber, RadiochemicalPurityPercent, MeanParticleSizeUm, ParticlesAbove150UmPercent, ParticleCountPerDose, pH, EndotoxinsEUPerVial, SterilityTest, ActivityMBq

Open utility

Related utilities
Tc-99m MAA Radiochemical Purity Checker API / calculation and rule-basedTc-99m
What it does

Utility performs: Separate control of bound Tc-99m, free pertechnetate and hydrolysed-reduced technetium. input.csv structure and numeric-value validation LabWare-compatible output.json generation

Why it is needed

Connects MAA product quality, lung perfusion, shunt calculation and radioembolization planning without separating release checks from quantitative interpretation.

Where and when to use it

during MAA preparation, V/Q studies, lung-shunt assessment and radioembolization planning. Medical use: pulmonary and ventilation, oncology and theranostics. Workflow stages: product release QC, dosimetry and therapy planning, imaging QC and quantitative interpretation.

Input fields

BatchNumber, RadiochemicalPurityPercent, FreePertechnetatePercent, HydrolyzedReducedTcPercent, TimeSincePreparationMin

Open utility

Related utilities
Tc-99m MAA Reconstitution and Resuspension Checker API / calculation and rule-basedTc-99m
What it does

Utility performs: Control of reconstitution volume, mixing, delay before withdrawal and resuspension before each dose withdrawal. input.csv structure and numeric-value validation LabWare-compatible output.json generation

Why it is needed

Connects MAA product quality, lung perfusion, shunt calculation and radioembolization planning without separating release checks from quantitative interpretation.

Where and when to use it

during MAA preparation, V/Q studies, lung-shunt assessment and radioembolization planning. Medical use: pulmonary and ventilation, oncology and theranostics. Workflow stages: synthesis, labelling and kit reconstitution, dosimetry and therapy planning, imaging QC and quantitative interpretation.

Input fields

BatchNumber, ReconstitutionVolumeMl, MixingCycles, DelayBeforeFirstWithdrawalMin, WithdrawalCount, ResuspensionBeforeEachWithdrawalFlag, VisualHomogeneityScore, pH

Open utility

Related utilities

Instrumental 7

Tc-99m DTPA Aerosol Deposition Quality Checker InstrumentalTc-99m
What it does

Utility performs: Assessment of lung deposition, central-to-peripheral distribution and oropharyngeal/gastric contamination. input.csv structure and numeric-value validation LabWare-compatible output.json generation

Why it is needed

Connects MAA product quality, lung perfusion, shunt calculation and radioembolization planning without separating release checks from quantitative interpretation.

Where and when to use it

during MAA preparation, V/Q studies, lung-shunt assessment and radioembolization planning. Medical use: renal and urinary, pulmonary and ventilation, hepatobiliary and GI. Workflow stages: product release QC, imaging QC and quantitative interpretation.

Input fields

BatchNumber, LungCounts, CentralLungCounts, PeripheralLungCounts, MouthCounts, StomachCounts, DeliveredActivityMBq, LoadedActivityMBq, MotionScore

Open utility

Related utilities
Tc-99m MAA Aggregation Stability Checker InstrumentalTc-99m
What it does

Utility performs: Comparison of particle-size distributions before and after storage to identify aggregation or particle breakdown. input.csv structure and numeric-value validation LabWare-compatible output.json generation

Why it is needed

Connects MAA product quality, lung perfusion, shunt calculation and radioembolization planning without separating release checks from quantitative interpretation.

Where and when to use it

during MAA preparation, V/Q studies, lung-shunt assessment and radioembolization planning. Medical use: pulmonary and ventilation, oncology and theranostics. Workflow stages: dosimetry and therapy planning, imaging QC and quantitative interpretation, stability, storage, decay and waste.

Input fields

BatchNumber, BaselineMeanSizeUm, FinalMeanSizeUm, BaselineD90Um, FinalD90Um, VisibleAggregateCount, StorageTimeMin, StorageTemperatureC

Open utility

Related utilities
Tc-99m MAA Injection Residual Activity Checker InstrumentalTc-99m
What it does

Utility performs: Decay correction and calculation of administered activity and residual fraction in syringe or line. input.csv structure and numeric-value validation LabWare-compatible output.json generation

Why it is needed

Connects MAA product quality, lung perfusion, shunt calculation and radioembolization planning without separating release checks from quantitative interpretation.

Where and when to use it

during MAA preparation, V/Q studies, lung-shunt assessment and radioembolization planning. Medical use: pulmonary and ventilation, oncology and theranostics. Workflow stages: dosimetry and therapy planning, imaging QC and quantitative interpretation, stability, storage, decay and waste.

Input fields

BatchNumber, PreInjectionActivityMBq, PostInjectionResidualMBq, LineResidualMBq, ElapsedTimeMin, HalfLifeHours, MaxResidualPercent

Open utility

Related utilities
Tc-99m MAA Particle Size Distribution Analyzer InstrumentalTc-99m
What it does

Utility performs: Review of D10/D50/D90, mean size and the fraction of particles outside the configured size range. input.csv structure and numeric-value validation LabWare-compatible output.json generation

Why it is needed

Connects MAA product quality, lung perfusion, shunt calculation and radioembolization planning without separating release checks from quantitative interpretation.

Where and when to use it

during MAA preparation, V/Q studies, lung-shunt assessment and radioembolization planning. Medical use: pulmonary and ventilation, oncology and theranostics. Workflow stages: dosimetry and therapy planning, imaging QC and quantitative interpretation.

Input fields

BatchNumber, MeanParticleSizeUm, D10Um, D50Um, D90Um, ParticlesBelow10UmPercent, ParticlesAbove90UmPercent, ParticlesAbove150Count

Open utility

Related utilities
Tc-99m MAA Vial Withdrawal Uniformity Checker InstrumentalTc-99m
What it does

Utility performs: Assessment of particle-count variability across sequential withdrawals from one vial. input.csv structure and numeric-value validation LabWare-compatible output.json generation

Why it is needed

Connects MAA product quality, lung perfusion, shunt calculation and radioembolization planning without separating release checks from quantitative interpretation.

Where and when to use it

during MAA preparation, V/Q studies, lung-shunt assessment and radioembolization planning. Medical use: pulmonary and ventilation, oncology and theranostics. Workflow stages: dosimetry and therapy planning, imaging QC and quantitative interpretation, instruments, devices and radiation safety.

Input fields

BatchNumber, Dose1ParticleCount, Dose2ParticleCount, Dose3ParticleCount, Dose4ParticleCount, Dose5ParticleCount, MaxAllowedCVPercent

Open utility

Related utilities
Technegas Particle and Delivery Quality Checker InstrumentalGeneral RPH
What it does

Utility performs: Check of generation temperature, aerodynamic particle size, delivery time, inhalation count and oropharyngeal contamination. input.csv structure and numeric-value validation LabWare-compatible output.json generation

Why it is needed

Connects MAA product quality, lung perfusion, shunt calculation and radioembolization planning without separating release checks from quantitative interpretation.

Where and when to use it

during MAA preparation, V/Q studies, lung-shunt assessment and radioembolization planning. Medical use: renal and urinary, pulmonary and ventilation, hepatobiliary and GI. Workflow stages: product release QC, imaging QC and quantitative interpretation.

Input fields

BatchNumber, GenerationTemperatureC, MedianParticleSizeNm, DeliveryDelayMin, InhalationCount, LungCounts, MouthCounts, OxygenContaminationPercent

Open utility

Related utilities
V/Q Study Acquisition Quality Checker InstrumentalGeneral RPH
What it does

Utility performs: Check of ventilation/perfusion count statistics, projection number, motion, inter-series interval and registration. input.csv structure and numeric-value validation LabWare-compatible output.json generation

Why it is needed

Connects MAA product quality, lung perfusion, shunt calculation and radioembolization planning without separating release checks from quantitative interpretation.

Where and when to use it

during MAA preparation, V/Q studies, lung-shunt assessment and radioembolization planning. Medical use: renal and urinary, pulmonary and ventilation. Workflow stages: product release QC, imaging QC and quantitative interpretation.

Input fields

BatchNumber, VentilationTotalCounts, PerfusionTotalCounts, VentilationProjectionCount, PerfusionProjectionCount, InterSeriesIntervalMin, MotionScore, RegistrationScore, EnergyWindowDeviationPercent

Open utility

Related utilities

Medical devices 7

Tc-99m MAA / Y-90 Concordance Checker Medical devicesTc-99mY-90
What it does

Utility performs: Comparison of lung shunt, tumour-to-liver ratio, extrahepatic deposition and spatial concordance between MAA and Y-90. input.csv structure and numeric-value validation LabWare-compatible output.json generation

Why it is needed

Connects MAA product quality, lung perfusion, shunt calculation and radioembolization planning without separating release checks from quantitative interpretation.

Where and when to use it

during MAA preparation, V/Q studies, lung-shunt assessment and radioembolization planning. Medical use: pulmonary and ventilation, hepatobiliary and GI, oncology and theranostics. Workflow stages: dosimetry and therapy planning, imaging QC and quantitative interpretation.

Input fields

BatchNumber, MAALungShuntPercent, Y90LungShuntPercent, MAATumorToLiverRatio, Y90TumorToLiverRatio, SpatialDiceCoefficient, ExtrahepaticMatchFlag, MaxLungShuntDifferencePercent

Open utility

Related utilities
Tc-99m MAA Dosimetry Pre-Planner Medical devicesTc-99m
What it does

Tc-99m MAA Dosimetry Pre-Planner Utility performs: Calculation of indicative lung, target and normal-liver absorbed doses using activity, shunt fraction and coefficients from the approved protocol. input.csv structure and numeric-value validation

Why it is needed

Connects MAA product quality, lung perfusion, shunt calculation and radioembolization planning without separating release checks from quantitative interpretation.

Where and when to use it

during MAA preparation, V/Q studies, lung-shunt assessment and radioembolization planning. Medical use: pulmonary and ventilation, hepatobiliary and GI, oncology and theranostics. Workflow stages: dosimetry and therapy planning, imaging QC and quantitative interpretation.

Input fields

BatchNumber, PlannedActivityGBq, LungShuntPercent, LungDoseCoefficientGyPerGBq, TargetDoseCoefficientGyPerGBq, NormalLiverDoseCoefficientGyPerGBq, MaxLungDoseGy, MinTargetDoseGy, MaxNormalLiverDoseGy

Open utility

Related utilities
Tc-99m MAA Extrahepatic Deposition Checker Medical devicesTc-99m
What it does

Utility performs: Calculation of the activity fraction in stomach, duodenum and other extrahepatic regions after background correction. input.csv structure and numeric-value validation LabWare-compatible output.json generation

Why it is needed

Connects MAA product quality, lung perfusion, shunt calculation and radioembolization planning without separating release checks from quantitative interpretation.

Where and when to use it

during MAA preparation, V/Q studies, lung-shunt assessment and radioembolization planning. Medical use: pulmonary and ventilation, hepatobiliary and GI, oncology and theranostics. Workflow stages: dosimetry and therapy planning, imaging QC and quantitative interpretation.

Input fields

BatchNumber, LiverCounts, LungCounts, StomachCounts, DuodenumCounts, OtherExtrahepaticCounts, BackgroundCounts, MaxExtrahepaticFractionPercent

Open utility

Related utilities
Tc-99m MAA Lung Perfusion Quality Checker Medical devicesTc-99m
What it does

Utility performs: Review of administered activity and particle count, injection-system residual, acquisition timing, projection completeness and patient motion. input.csv structure and numeric-value validation LabWare-compatible output.json generation

Why it is needed

Connects MAA product quality, lung perfusion, shunt calculation and radioembolization planning without separating release checks from quantitative interpretation.

Where and when to use it

during MAA preparation, V/Q studies, lung-shunt assessment and radioembolization planning. Medical use: pulmonary and ventilation, oncology and theranostics. Workflow stages: product release QC, dosimetry and therapy planning, imaging QC and quantitative interpretation.

Input fields

BatchNumber, AdministeredActivityMBq, AdministeredParticleCount, InjectionResidualPercent, AcquisitionStartMin, ProjectionCount, TotalCounts, MotionScore

Open utility

Related utilities
Tc-99m MAA Lung Shunt Fraction Calculator Medical devicesTc-99m
What it does

Utility performs: Calculation of lung-shunt fraction from background-corrected lung and liver counts with protocol-limit review. input.csv structure and numeric-value validation LabWare-compatible output.json generation

Why it is needed

Connects MAA product quality, lung perfusion, shunt calculation and radioembolization planning without separating release checks from quantitative interpretation.

Where and when to use it

during MAA preparation, V/Q studies, lung-shunt assessment and radioembolization planning. Medical use: pulmonary and ventilation, hepatobiliary and GI, oncology and theranostics. Workflow stages: dosimetry and therapy planning, imaging QC and quantitative interpretation.

Input fields

BatchNumber, LungCounts, LiverCounts, LungBackgroundCounts, LiverBackgroundCounts, MaxAllowedLungShuntPercent

Open utility

Related utilities
Tc-99m MAA Particle Count and Dose Planner Medical devicesTc-99m
What it does

Tc-99m MAA Particle Count and Dose Planner Utility performs: Calculation of the administered particle count from vial content, withdrawn activity and residual activity. input.csv structure and numeric-value validation

Why it is needed

Connects MAA product quality, lung perfusion, shunt calculation and radioembolization planning without separating release checks from quantitative interpretation.

Where and when to use it

during MAA preparation, V/Q studies, lung-shunt assessment and radioembolization planning. Medical use: pulmonary and ventilation, oncology and theranostics. Workflow stages: dosimetry and therapy planning, imaging QC and quantitative interpretation.

Input fields

BatchNumber, VialParticleCount, VialActivityMBq, WithdrawnActivityMBq, ResidualActivityMBq, PulmonaryHypertensionFlag

Open utility

Related utilities
Ventilation/Perfusion Mismatch Analyzer Medical devicesGeneral RPH
What it does

Utility performs: Calculation of mismatched segment equivalents, perfusion-defect extent and ventilation/perfusion regional concordance. input.csv structure and numeric-value validation LabWare-compatible output.json generation

Why it is needed

Connects MAA product quality, lung perfusion, shunt calculation and radioembolization planning without separating release checks from quantitative interpretation.

Where and when to use it

during MAA preparation, V/Q studies, lung-shunt assessment and radioembolization planning. Medical use: renal and urinary, pulmonary and ventilation. Workflow stages: imaging QC and quantitative interpretation.

Input fields

BatchNumber, PerfusionDefectSegmentEquivalents, MatchedDefectSegmentEquivalents, TotalEvaluableSegments, PerfusionDefectExtentPercent, VentilationPerfusionAlignmentScore, MinAlignmentScore

Open utility

Related utilities
HIDA, hepatobiliary and GI nuclear medicine 20

Hepatobiliary tracers, pertechnetate for Meckel/gastric mucosa, gastric emptying, GI transit, RBC bleeding and liver/spleen sulfur colloid.

Open package

API / calculation and rule-based 8

Tc-99m Disofenin Quality Checker API / calculation and rule-basedTc-99m
What it does

Utility performs: Quality review of Tc-99m disofenin for dynamic hepatobiliary scintigraphy. input.csv structure and numeric-value validation LabWare-compatible output.json generation

Why it is needed

Supports hepatobiliary and gastrointestinal studies in which tracer quality, acquisition timing and functional calculations must be reviewed together.

Where and when to use it

during HIDA product release and functional GI protocols where product quality must be linked with acquisition and calculation integrity. Medical use: hepatobiliary and GI. Workflow stages: synthesis, labelling and kit reconstitution, product release QC, imaging QC and quantitative interpretation.

Input fields

BatchNumber, RadiochemicalPurityPercent, LabelingYieldPercent, FreePertechnetatePercent, pH, TimeSinceLabelingMin, EndotoxinsEUPerVial, SterilityTest

Open utility

Related utilities
Tc-99m HIDA Quality Checker API / calculation and rule-basedTc-99m
What it does

Utility performs: Control of radiochemical purity, free pertechnetate, pH, sterility, endotoxins and use time for a HIDA preparation. input.csv structure and numeric-value validation LabWare-compatible output.json generation

Why it is needed

Supports hepatobiliary and gastrointestinal studies in which tracer quality, acquisition timing and functional calculations must be reviewed together.

Where and when to use it

during HIDA product release and functional GI protocols where product quality must be linked with acquisition and calculation integrity. Medical use: hepatobiliary and GI. Workflow stages: product release QC, imaging QC and quantitative interpretation.

Input fields

BatchNumber, RadiochemicalPurityPercent, FreePertechnetatePercent, pH, EndotoxinsEUPerVial, SterilityTest, TimeSincePreparationMin, ActivityMBq

Open utility

Related utilities
Tc-99m Mebrofenin Quality Checker API / calculation and rule-basedTc-99m
What it does

Utility performs: Quality review of Tc-99m mebrofenin before hepatobiliary imaging and quantitative liver-function assessment. input.csv structure and numeric-value validation LabWare-compatible output.json generation

Why it is needed

Supports hepatobiliary and gastrointestinal studies in which tracer quality, acquisition timing and functional calculations must be reviewed together.

Where and when to use it

during HIDA product release and functional GI protocols where product quality must be linked with acquisition and calculation integrity. Medical use: hepatobiliary and GI. Workflow stages: synthesis, labelling and kit reconstitution, product release QC, imaging QC and quantitative interpretation.

Input fields

BatchNumber, RadiochemicalPurityPercent, LabelingYieldPercent, FreePertechnetatePercent, HydrolyzedReducedTcPercent, pH, TimeSinceLabelingMin, SterilityTest, EndotoxinsEUPerVial

Open utility

Related utilities
Tc-99m Nanocolloid Particle Size Analyzer API / calculation and rule-basedTc-99m
What it does

Utility checks critical particle size parameters of Tc-99m Nanocolloid: Mean size (<80 nm) D90 (<100 nm) Polydispersity index (PDI <0.2)

Why it is needed

Supports hepatobiliary and gastrointestinal studies in which tracer quality, acquisition timing and functional calculations must be reviewed together.

Where and when to use it

during HIDA product release and functional GI protocols where product quality must be linked with acquisition and calculation integrity. Medical use: pulmonary and ventilation, hepatobiliary and GI, lymphatic, infection and inflammation, oncology and theranostics. Workflow stages: product release QC, stability, storage, decay and waste, instruments, devices and radiation safety.

Input fields

BatchNumber, MeanParticleSizeNm, ParticleSizeD90Nm, PolydispersityIndex, RadiochemicalPurityPercent, FreeTechnetiumPercent, AggregatesPercent, pH, ActivityMBq, SterilityTest

Open utility

Related utilities
Tc-99m Nanocolloid Quality Checker API / calculation and rule-basedTc-99m
What it does

Utility performs: Control of radiochemical purity, particle-size distribution, free Tc-99m, pH, sterility and endotoxins. input.csv structure and numeric-value validation LabWare-compatible output.json generation

Why it is needed

Supports hepatobiliary and gastrointestinal studies in which tracer quality, acquisition timing and functional calculations must be reviewed together.

Where and when to use it

during HIDA product release and functional GI protocols where product quality must be linked with acquisition and calculation integrity. Medical use: hepatobiliary and GI, lymphatic, infection and inflammation. Workflow stages: product release QC.

Input fields

BatchNumber, RadiochemicalPurityPercent, FreePertechnetatePercent, MeanParticleSizeNm, D90Nm, PolydispersityIndex, pH, EndotoxinsEUPerVial, SterilityTest

Open utility

Related utilities
Tc-99m Sulfur Colloid Liver/Spleen Quality Checker API / calculation and rule-basedTc-99m
What it does

Utility performs: Control of colloid radiochemical purity, particle size, free Tc-99m and liver/spleen acquisition quality. input.csv structure and numeric-value validation LabWare-compatible output.json generation

Why it is needed

Supports hepatobiliary and gastrointestinal studies in which tracer quality, acquisition timing and functional calculations must be reviewed together.

Where and when to use it

during HIDA product release and functional GI protocols where product quality must be linked with acquisition and calculation integrity. Medical use: hepatobiliary and GI, bone and musculoskeletal. Workflow stages: product release QC, imaging QC and quantitative interpretation.

Input fields

BatchNumber, RadiochemicalPurityPercent, FreePertechnetatePercent, MeanParticleSizeNm, LiverCounts, SpleenCounts, BoneMarrowUptakePercent, MotionScore

Open utility

Related utilities
Tc-99m Tilmanocept Quality Checker API / calculation and rule-basedTc-99m
What it does

Utility performs: Control of labelling yield, radiochemical purity, free Tc-99m, pH, activity and use time of tilmanocept. input.csv structure and numeric-value validation LabWare-compatible output.json generation

Why it is needed

Supports hepatobiliary and gastrointestinal studies in which tracer quality, acquisition timing and functional calculations must be reviewed together.

Where and when to use it

during HIDA product release and functional GI protocols where product quality must be linked with acquisition and calculation integrity. Medical use: hepatobiliary and GI, lymphatic, infection and inflammation. Workflow stages: synthesis, labelling and kit reconstitution, product release QC.

Input fields

BatchNumber, LabelingYieldPercent, RadiochemicalPurityPercent, FreePertechnetatePercent, pH, ActivityMBq, TimeSincePreparationMin, EndotoxinsEUPerVial, SterilityTest

Open utility

Related utilities
Technetium99m Sulfur Colloid Checker API / calculation and rule-basedTc-99m
What it does

Utility checks critical parameters of Tc-99m Sulfur Colloid: Radiochemical purity (≥92%) Particle size (depends on application: liver/lymph) Boiling time (3-6 min) — CRITICAL!

Why it is needed

Supports hepatobiliary and gastrointestinal studies in which tracer quality, acquisition timing and functional calculations must be reviewed together.

Where and when to use it

during HIDA product release and functional GI protocols where product quality must be linked with acquisition and calculation integrity. Medical use: pulmonary and ventilation, hepatobiliary and GI, endocrine, thyroid and NET, bone and musculoskeletal, lymphatic, infection and inflammation, oncology and theranostics. Workflow stages: synthesis, labelling and kit reconstitution, product release QC, generators and isotope purity.

Input fields

BatchNumber, TotalActivityMBq, RadiochemicalPurityPercent, FreePertechnetatePercent, ParticleSizeMicrons, pH, EndotoxinsEU, SterilityTest, BoilingTimeMin, ProductType

Open utility

Related utilities

Instrumental 3

Injection Site Shine-Through Checker InstrumentalTc-99m
What it does

Utility performs: Assessment of injection-site-to-node count ratio, distance and shielding/geometry effectiveness. input.csv structure and numeric-value validation LabWare-compatible output.json generation

Why it is needed

Supports hepatobiliary and gastrointestinal studies in which tracer quality, acquisition timing and functional calculations must be reviewed together.

Where and when to use it

during HIDA product release and functional GI protocols where product quality must be linked with acquisition and calculation integrity. Medical use: hepatobiliary and GI, lymphatic, infection and inflammation. Workflow stages: instruments, devices and radiation safety.

Input fields

BatchNumber, InjectionSiteCountsPerSecond, NodeCountsPerSecond, BackgroundCountsPerSecond, InjectionToNodeDistanceCm, ShieldingReductionPercent, MaxInjectionToNodeRatio

Open utility

Related utilities
Lymphoscintigraphy Acquisition Quality Checker InstrumentalTc-99m
What it does

Utility performs: Check of early and delayed time points, count statistics, anatomical coverage, motion and injection-site saturation. input.csv structure and numeric-value validation LabWare-compatible output.json generation

Why it is needed

Supports hepatobiliary and gastrointestinal studies in which tracer quality, acquisition timing and functional calculations must be reviewed together.

Where and when to use it

during HIDA product release and functional GI protocols where product quality must be linked with acquisition and calculation integrity. Medical use: hepatobiliary and GI, lymphatic, infection and inflammation. Workflow stages: product release QC, imaging QC and quantitative interpretation.

Input fields

BatchNumber, EarlyImagingStartMin, DelayedImagingTimeMin, TotalCounts, AnatomicalCoverageScore, MotionScore, InjectionSiteSaturationPercent, NodeFieldIncludedFlag

Open utility

Related utilities
Sentinel Node Detection Threshold Checker InstrumentalTc-99m
What it does

Utility performs: Calculation of node-to-background ratio and review of gamma-probe sensitivity and minimum count threshold. input.csv structure and numeric-value validation LabWare-compatible output.json generation

Why it is needed

Supports hepatobiliary and gastrointestinal studies in which tracer quality, acquisition timing and functional calculations must be reviewed together.

Where and when to use it

during HIDA product release and functional GI protocols where product quality must be linked with acquisition and calculation integrity. Medical use: hepatobiliary and GI, lymphatic, infection and inflammation.

Input fields

BatchNumber, NodeCountsPerSecond, BackgroundCountsPerSecond, ProbeSensitivityCpsPerMBq, MinNodeToBackgroundRatio, MinProbeSensitivityCpsPerMBq, MinNodeCountsPerSecond

Open utility

Related utilities

Medical devices 9

Gallbladder Ejection Fraction Calculator Medical devicesTc-99m
What it does

Utility performs: Calculation of gallbladder ejection fraction from background-corrected pre- and post-stimulation counts. input.csv structure and numeric-value validation LabWare-compatible output.json generation

Why it is needed

Supports hepatobiliary and gastrointestinal studies in which tracer quality, acquisition timing and functional calculations must be reviewed together.

Where and when to use it

during HIDA product release and functional GI protocols where product quality must be linked with acquisition and calculation integrity. Medical use: renal and urinary, hepatobiliary and GI, cardiovascular. Workflow stages: imaging QC and quantitative interpretation.

Input fields

BatchNumber, PreStimulusGallbladderCounts, PostStimulusGallbladderCounts, PreBackgroundCounts, PostBackgroundCounts, MinExpectedEjectionFractionPercent, InfusionDurationMin

Open utility

Related utilities
Hepatobiliary Extraction Fraction Calculator Medical devicesTc-99m
What it does

Utility performs: Calculation of hepatic extraction fraction from background-corrected early and late counts with review against the protocol minimum. input.csv structure and numeric-value validation LabWare-compatible output.json generation

Why it is needed

Supports hepatobiliary and gastrointestinal studies in which tracer quality, acquisition timing and functional calculations must be reviewed together.

Where and when to use it

during HIDA product release and functional GI protocols where product quality must be linked with acquisition and calculation integrity. Medical use: hepatobiliary and GI. Workflow stages: imaging QC and quantitative interpretation.

Input fields

BatchNumber, EarlyLiverCounts, LateLiverCounts, EarlyBackgroundCounts, LateBackgroundCounts, MinExpectedExtractionPercent, MotionScore

Open utility

Related utilities
Hepatobiliary Transit Quality Checker Medical devicesTc-99m
What it does

Utility performs: Review of liver, bile-duct, gallbladder and bowel visualization time points. input.csv structure and numeric-value validation LabWare-compatible output.json generation

Why it is needed

Supports hepatobiliary and gastrointestinal studies in which tracer quality, acquisition timing and functional calculations must be reviewed together.

Where and when to use it

during HIDA product release and functional GI protocols where product quality must be linked with acquisition and calculation integrity. Medical use: renal and urinary, hepatobiliary and GI. Workflow stages: product release QC, imaging QC and quantitative interpretation.

Input fields

BatchNumber, LiverVisualizationMin, BileDuctVisualizationMin, GallbladderVisualizationMin, BowelVisualizationMin, DelayedImagingPerformedFlag, MotionScore

Open utility

Related utilities
Sentinel Node Injection Quality Checker Medical devicesTc-99m
What it does

Utility performs: Review of planned/administered activity, syringe residual, injection-site count and interval to surgery. input.csv structure and numeric-value validation LabWare-compatible output.json generation

Why it is needed

Supports hepatobiliary and gastrointestinal studies in which tracer quality, acquisition timing and functional calculations must be reviewed together.

Where and when to use it

during HIDA product release and functional GI protocols where product quality must be linked with acquisition and calculation integrity. Medical use: hepatobiliary and GI, lymphatic, infection and inflammation. Workflow stages: product release QC.

Input fields

BatchNumber, PlannedActivityMBq, AdministeredActivityMBq, ResidualActivityMBq, InjectionSiteCount, TimeToSurgeryMin, MaxActivityDeviationPercent, MaxTimeToSurgeryMin

Open utility

Related utilities
Tc-99m Gastric Emptying Quality Checker Medical devicesTc-99m
What it does

Utility performs: Review of standard-meal completion, acquisition time points and activity retention at 1, 2 and 4 hours. input.csv structure and numeric-value validation LabWare-compatible output.json generation

Why it is needed

Supports hepatobiliary and gastrointestinal studies in which tracer quality, acquisition timing and functional calculations must be reviewed together.

Where and when to use it

during HIDA product release and functional GI protocols where product quality must be linked with acquisition and calculation integrity. Medical use: hepatobiliary and GI. Workflow stages: product release QC, imaging QC and quantitative interpretation.

Input fields

BatchNumber, MealConsumedPercent, RetentionAt1HourPercent, RetentionAt2HoursPercent, RetentionAt4HoursPercent, AcquisitionTimingDeviationMin, MotionScore

Open utility

Related utilities
Tc-99m Gastrointestinal Transit Analyzer Medical devicesTc-99m
What it does

Utility performs: Review of gastric half-time, caecal arrival and colonic geometric centre at protocol time points. input.csv structure and numeric-value validation LabWare-compatible output.json generation

Why it is needed

Supports hepatobiliary and gastrointestinal studies in which tracer quality, acquisition timing and functional calculations must be reviewed together.

Where and when to use it

during HIDA product release and functional GI protocols where product quality must be linked with acquisition and calculation integrity. Medical use: hepatobiliary and GI. Workflow stages: imaging QC and quantitative interpretation.

Input fields

BatchNumber, GastricHalfTimeMin, CecalArrivalHours, ColonGeometricCenter24h, ColonGeometricCenter48h, MinGC24h, MinGC48h, AcquisitionCompleteFlag

Open utility

Related utilities
Tc-99m Pertechnetate Gastric Mucosa Quality Checker Medical devicesTc-99m
What it does

Utility performs: Quality review of dynamic imaging for suspected ectopic gastric mucosa. input.csv structure and numeric-value validation LabWare-compatible output.json generation

Why it is needed

Supports hepatobiliary and gastrointestinal studies in which tracer quality, acquisition timing and functional calculations must be reviewed together.

Where and when to use it

during HIDA product release and functional GI protocols where product quality must be linked with acquisition and calculation integrity. Medical use: hepatobiliary and GI, endocrine, thyroid and NET. Workflow stages: product release QC, imaging QC and quantitative interpretation.

Input fields

BatchNumber, CandidateFocusCounts, BackgroundCounts, FocusAppearanceMin, GastricAppearanceMin, FocusPersistenceMin, AcquisitionDurationMin, MinFocusToBackgroundRatio

Open utility

Related utilities
Tc-99m Pertechnetate Meckel Scan Quality Checker Medical devicesTc-99m
What it does

Utility performs: Review of lesion-to-stomach temporal concordance, lesion-to-background ratio, acquisition duration and patient motion. input.csv structure and numeric-value validation LabWare-compatible output.json generation

Why it is needed

Supports hepatobiliary and gastrointestinal studies in which tracer quality, acquisition timing and functional calculations must be reviewed together.

Where and when to use it

during HIDA product release and functional GI protocols where product quality must be linked with acquisition and calculation integrity. Medical use: hepatobiliary and GI, endocrine, thyroid and NET. Workflow stages: product release QC, imaging QC and quantitative interpretation.

Input fields

BatchNumber, LesionCounts, BackgroundCounts, LesionAppearanceMin, StomachAppearanceMin, AcquisitionDurationMin, MotionScore, MinLesionToBackgroundRatio, MaxAppearanceDifferenceMin

Open utility

Related utilities
Tc-99m RBC Gastrointestinal Bleeding Quality Checker Medical devicesTc-99m
What it does

Utility performs: Review of RBC labelling quality, dynamic and delayed imaging duration, motion and focus-to-background ratio. input.csv structure and numeric-value validation LabWare-compatible output.json generation

Why it is needed

Supports hepatobiliary and gastrointestinal studies in which tracer quality, acquisition timing and functional calculations must be reviewed together.

Where and when to use it

during HIDA product release and functional GI protocols where product quality must be linked with acquisition and calculation integrity. Medical use: hepatobiliary and GI, blood, cells and marrow. Workflow stages: synthesis, labelling and kit reconstitution, product release QC, imaging QC and quantitative interpretation.

Input fields

BatchNumber, LabelingEfficiencyPercent, FreeActivityPercent, DynamicAcquisitionDurationMin, DelayedImagingPerformedFlag, MotionScore, FocusCounts, BackgroundCounts, MinFocusToBackgroundRatio

Open utility

Related utilities
labelled cells and blood-pool workflows 24

Leukocytes, red blood cells, platelets and autologous cell workflows: labeling efficiency, viability, free activity, recovery and release before reinjection.

Open package

API / calculation and rule-based 9

Chromium51 EDTA Checker API / calculation and rule-basedCr-51
What it does

Utility checks critical parameters of chromium-51 EDTA: Radiochemical purity (≥95%) — fraction of Cr-51 bound to EDTA Free chromium-51 (≤5%) — unreacted chromium, accumulates in liver/spleen pH (4.0–7.0) — critical for complex stability and safety

Why it is needed

Supports reproducible blood-cell labelling, free-activity control, cell viability and release before reinjection.

Where and when to use it

during autologous cell radiopharmaceutical preparation, labeling assessment and release before reinjection. Medical use: renal and urinary, hepatobiliary and GI, blood, cells and marrow. Workflow stages: product release QC, generators and isotope purity, imaging QC and quantitative interpretation.

Input fields

BatchNumber, ActivityMBqPerML, RadiochemicalPurityPercent, FreeChromiumPercent, pH, EndotoxinsEU, SterilityTest, Appearance, PreparationDate

Open utility

Related utilities
Gallium-67 Citrate Quality Checker API / calculation and rule-basedGa-67
What it does

Utility performs: Control of radiochemical and radionuclidic purity, free gallium, pH, sterility, endotoxins and activity. input.csv structure and numeric-value validation LabWare-compatible output.json generation

Why it is needed

Supports reproducible blood-cell labelling, free-activity control, cell viability and release before reinjection.

Where and when to use it

during autologous cell radiopharmaceutical preparation, labeling assessment and release before reinjection. Medical use: blood, cells and marrow, lymphatic, infection and inflammation. Workflow stages: product release QC, generators and isotope purity, imaging QC and quantitative interpretation.

Input fields

BatchNumber, RadiochemicalPurityPercent, RadionuclidicPurityPercent, FreeGalliumPercent, pH, EndotoxinsEUPerVial, SterilityTest, ActivityMBq

Open utility

Related utilities
In-111 Platelet Labeling Quality Checker API / calculation and rule-basedIn-111Tc-99m
What it does

Utility performs: Control of labelling efficiency, viability, free In-111, aggregates, process time and sterility. input.csv structure and numeric-value validation LabWare-compatible output.json generation

Why it is needed

Supports reproducible blood-cell labelling, free-activity control, cell viability and release before reinjection.

Where and when to use it

during autologous cell radiopharmaceutical preparation, labeling assessment and release before reinjection. Medical use: blood, cells and marrow. Workflow stages: synthesis, labelling and kit reconstitution, product release QC.

Input fields

BatchNumber, LabelingEfficiencyPercent, PlateletViabilityPercent, FreeIndiumPercent, AggregatePercent, ProcessTimeMin, SterilityTest, EndotoxinsEUPerVial

Open utility

Related utilities
Indium111 WBC Labeling Checker API / calculation and rule-basedIn-111
What it does

Utility checks critical parameters of autologous leukocytes labeled with Indium-111: Labeling efficiency (≥80%) Free Indium-111 impurity (≤20%) Cell viability (≥95%)

Why it is needed

Supports reproducible blood-cell labelling, free-activity control, cell viability and release before reinjection.

Where and when to use it

during autologous cell radiopharmaceutical preparation, labeling assessment and release before reinjection. Medical use: hepatobiliary and GI, bone and musculoskeletal, blood, cells and marrow, lymphatic, infection and inflammation. Workflow stages: synthesis, labelling and kit reconstitution, product release QC, generators and isotope purity.

Input fields

BatchNumber, LabelingEfficiencyPercent, FreeIndium111Percent, CellViabilityPercent, WBCCountMillion, pH, EndotoxinsEU, SterilityTest, HemoglobinContaminationMgPerDl, IncubationTimeMinutes

Open utility

Related utilities
Tc-99m Besilesomab Quality Checker API / calculation and rule-basedGa-67Tc-99m
What it does

Utility performs: Control of labelling yield, RCP, free Tc-99m, aggregates and contraindication flags related to HAMA/previous exposure. input.csv structure and numeric-value validation LabWare-compatible output.json generation

Why it is needed

Supports reproducible blood-cell labelling, free-activity control, cell viability and release before reinjection.

Where and when to use it

during autologous cell radiopharmaceutical preparation, labeling assessment and release before reinjection. Medical use: blood, cells and marrow, lymphatic, infection and inflammation. Workflow stages: synthesis, labelling and kit reconstitution, product release QC, imaging QC and quantitative interpretation.

Input fields

BatchNumber, LabelingYieldPercent, RadiochemicalPurityPercent, FreePertechnetatePercent, AggregatePercent, HAMAContraindicationFlag, PreviousBesilesomabExposureFlag, pH, SterilityTest

Open utility

Related utilities
Tc-99m HMPAO WBC Labeling Quality Checker API / calculation and rule-basedTc-99m
What it does

Utility performs: Comprehensive control of labelling efficiency, cell viability, free activity, process time and release before reinjection. input.csv structure and numeric-value validation LabWare-compatible output.json generation

Why it is needed

Supports reproducible blood-cell labelling, free-activity control, cell viability and release before reinjection.

Where and when to use it

during autologous cell radiopharmaceutical preparation, labeling assessment and release before reinjection. Medical use: blood, cells and marrow, lymphatic, infection and inflammation. Workflow stages: synthesis, labelling and kit reconstitution, product release QC, imaging QC and quantitative interpretation.

Input fields

BatchNumber, LabelingEfficiencyPercent, CellViabilityPercent, FreeActivityPercent, CellRecoveryPercent, AggregatePercent, ProcessTimeMin, ProcessTemperatureC, SterilityTest

Open utility

Related utilities
Tc-99m Platelet Labeling Quality Checker API / calculation and rule-basedIn-111Tc-99m
What it does

Utility performs: Control of Tc-99m platelet labelling efficiency, viability, free activity and aggregates. input.csv structure and numeric-value validation LabWare-compatible output.json generation

Why it is needed

Supports reproducible blood-cell labelling, free-activity control, cell viability and release before reinjection.

Where and when to use it

during autologous cell radiopharmaceutical preparation, labeling assessment and release before reinjection. Medical use: blood, cells and marrow. Workflow stages: synthesis, labelling and kit reconstitution, product release QC.

Input fields

BatchNumber, LabelingEfficiencyPercent, PlateletViabilityPercent, FreeTechnetiumPercent, RadiochemicalPurityPercent, AggregatePercent, ProcessTimeMin, SterilityTest

Open utility

Related utilities
Tc-99m Sulesomab Quality Checker API / calculation and rule-basedGa-67Tc-99m
What it does

Utility performs: Control of labelling yield, radiochemical purity, free Tc-99m, aggregates, pH, sterility and use time. input.csv structure and numeric-value validation LabWare-compatible output.json generation

Why it is needed

Supports reproducible blood-cell labelling, free-activity control, cell viability and release before reinjection.

Where and when to use it

during autologous cell radiopharmaceutical preparation, labeling assessment and release before reinjection. Medical use: blood, cells and marrow, lymphatic, infection and inflammation. Workflow stages: synthesis, labelling and kit reconstitution, product release QC, imaging QC and quantitative interpretation.

Input fields

BatchNumber, LabelingYieldPercent, RadiochemicalPurityPercent, FreePertechnetatePercent, AggregatePercent, pH, TimeSincePreparationMin, EndotoxinsEUPerVial, SterilityTest

Open utility

Related utilities
Technetium99m Red Blood Cell Checker API / calculation and rule-basedTc-99m
What it does

Utility checks critical parameters of Tc-99m RBC: Labeling efficiency (≥95%) Free pertechnetate (≤3%) Colloidal technetium (≤2%)

Why it is needed

Supports reproducible blood-cell labelling, free-activity control, cell viability and release before reinjection.

Where and when to use it

during autologous cell radiopharmaceutical preparation, labeling assessment and release before reinjection. Medical use: hepatobiliary and GI, cardiovascular, endocrine, thyroid and NET, bone and musculoskeletal, blood, cells and marrow, oncology and theranostics. Workflow stages: synthesis, labelling and kit reconstitution, product release QC, generators and isotope purity.

Input fields

BatchNumber, TotalActivityMBq, LabelingEfficiencyPercent, FreePertechnetatePercent, ReducedHydrolyzedTcPercent, pH, EndotoxinsEU, SterilityTest, HematocritPercent, LabelingMethod

Open utility

Related utilities

Instrumental 7

Antigranulocyte Antibody Imaging Quality Checker InstrumentalGa-67
What it does

Utility performs: Check of administered activity, imaging time points, count statistics, motion, target-to-background ratio and marrow symmetry. input.csv structure and numeric-value validation LabWare-compatible output.json generation

Why it is needed

Supports reproducible blood-cell labelling, free-activity control, cell viability and release before reinjection.

Where and when to use it

during autologous cell radiopharmaceutical preparation, labeling assessment and release before reinjection. Medical use: bone and musculoskeletal, blood, cells and marrow, lymphatic, infection and inflammation. Workflow stages: product release QC, imaging QC and quantitative interpretation.

Input fields

BatchNumber, AdministeredActivityMBq, EarlyImagingTimeHours, DelayedImagingTimeHours, TotalCounts, MotionScore, TargetCounts, BackgroundCounts, MarrowSymmetryScore, MinTargetToBackgroundRatio

Open utility

Related utilities
Cell Labeling Viability Checker InstrumentalIn-111Tc-99m
What it does

Utility performs: Comparison of pre- and post-labelling viability, cell recovery, apoptosis and aggregate fraction. input.csv structure and numeric-value validation LabWare-compatible output.json generation

Why it is needed

Supports reproducible blood-cell labelling, free-activity control, cell viability and release before reinjection.

Where and when to use it

during autologous cell radiopharmaceutical preparation, labeling assessment and release before reinjection. Medical use: blood, cells and marrow. Workflow stages: synthesis, labelling and kit reconstitution.

Input fields

BatchNumber, PreLabelingViabilityPercent, PostLabelingViabilityPercent, PreLabelingCellCountMillion, PostLabelingCellCountMillion, ApoptoticCellsPercent, AggregatePercent, MinPostLabelingViabilityPercent, MinRecoveryPercent

Open utility

Related utilities
Cr-51 RBC Labeling Efficiency Checker InstrumentalCr-51
What it does

Utility performs: Calculation of activity bound to red cells relative to total cell and plasma activity. input.csv structure and numeric-value validation LabWare-compatible output.json generation

Why it is needed

Supports reproducible blood-cell labelling, free-activity control, cell viability and release before reinjection.

Where and when to use it

during autologous cell radiopharmaceutical preparation, labeling assessment and release before reinjection. Medical use: blood, cells and marrow. Workflow stages: synthesis, labelling and kit reconstitution.

Input fields

BatchNumber, CellFractionActivityKcpm, PlasmaFractionActivityKcpm, WashFractionActivityKcpm, MinLabelingEfficiencyPercent

Open utility

Related utilities
Cr-51 RBC Sample Timing Checker InstrumentalCr-51
What it does

Utility performs: Check of actual serial-sample timing against the approved red-cell survival protocol. input.csv structure and numeric-value validation LabWare-compatible output.json generation

Why it is needed

Supports reproducible blood-cell labelling, free-activity control, cell viability and release before reinjection.

Where and when to use it

during autologous cell radiopharmaceutical preparation, labeling assessment and release before reinjection. Medical use: blood, cells and marrow.

Input fields

BatchNumber, InitialSampleHours, Day7SampleDay, Day14SampleDay, Day21SampleDay, AllowedInitialDeviationHours, AllowedDayDeviation

Open utility

Related utilities
WBC Free Activity Checker InstrumentalTc-99m
What it does

Utility performs: Calculation of unbound activity in supernatant and wash fractions. input.csv structure and numeric-value validation LabWare-compatible output.json generation

Why it is needed

Supports reproducible blood-cell labelling, free-activity control, cell viability and release before reinjection.

Where and when to use it

during autologous cell radiopharmaceutical preparation, labeling assessment and release before reinjection. Medical use: blood, cells and marrow, lymphatic, infection and inflammation. Workflow stages: product release QC, imaging QC and quantitative interpretation.

Input fields

BatchNumber, CellPelletActivityMBq, SupernatantActivityMBq, Wash1ActivityMBq, Wash2ActivityMBq, MaxFreeActivityPercent

Open utility

Related utilities
WBC Labeling Time and Temperature Checker InstrumentalTc-99m
What it does

Utility performs: Control of intervals between blood collection, labelling start/end and reinjection, plus process temperature. input.csv structure and numeric-value validation LabWare-compatible output.json generation

Why it is needed

Supports reproducible blood-cell labelling, free-activity control, cell viability and release before reinjection.

Where and when to use it

during autologous cell radiopharmaceutical preparation, labeling assessment and release before reinjection. Medical use: blood, cells and marrow, lymphatic, infection and inflammation. Workflow stages: synthesis, labelling and kit reconstitution, product release QC, imaging QC and quantitative interpretation.

Input fields

BatchNumber, CollectionToLabelingStartMin, LabelingDurationMin, LabelingEndToReinjectionMin, ProcessTemperatureC, MaxTotalProcessTimeMin

Open utility

Related utilities
WBC Viability and Recovery Checker InstrumentalTc-99m
What it does

Utility performs: Comparison of pre- and post-process cell counts, viability and aggregate fraction. input.csv structure and numeric-value validation LabWare-compatible output.json generation

Why it is needed

Supports reproducible blood-cell labelling, free-activity control, cell viability and release before reinjection.

Where and when to use it

during autologous cell radiopharmaceutical preparation, labeling assessment and release before reinjection. Medical use: blood, cells and marrow, lymphatic, infection and inflammation. Workflow stages: product release QC, imaging QC and quantitative interpretation.

Input fields

BatchNumber, PreProcessCellCountMillion, PostProcessCellCountMillion, ViabilityPercent, AggregatePercent, MinRecoveryPercent

Open utility

Related utilities

Medical devices 8

Autologous Cell Labeling Release Checker Medical devicesIn-111Tc-99m
What it does

Utility performs: Final review of patient identity, viability, labelling efficiency, free activity, aggregates, sterility and endotoxins. input.csv structure and numeric-value validation LabWare-compatible output.json generation

Why it is needed

Supports reproducible blood-cell labelling, free-activity control, cell viability and release before reinjection.

Where and when to use it

during autologous cell radiopharmaceutical preparation, labeling assessment and release before reinjection. Medical use: blood, cells and marrow. Workflow stages: synthesis, labelling and kit reconstitution, product release QC.

Input fields

BatchNumber, PatientIdentityConfirmedFlag, CellViabilityPercent, LabelingEfficiencyPercent, FreeActivityPercent, AggregatePercent, SterilityTest, EndotoxinsEUPerVial, TimeToAdministrationMin

Open utility

Related utilities
Cr-51 Blood Volume Calculator Medical devicesCr-51
What it does

Utility performs: Calculation of total blood volume and red-cell volume by indicator dilution with haematocrit correction. input.csv structure and numeric-value validation LabWare-compatible output.json generation

Why it is needed

Supports reproducible blood-cell labelling, free-activity control, cell viability and release before reinjection.

Where and when to use it

during autologous cell radiopharmaceutical preparation, labeling assessment and release before reinjection. Medical use: blood, cells and marrow.

Input fields

BatchNumber, NetInjectedActivityKcpm, SampleActivityKcpm, SampleVolumeMl, VenousHematocritFraction, BodyHematocritCorrectionFactor, MinExpectedBloodVolumeMl, MaxExpectedBloodVolumeMl

Open utility

Related utilities
Cr-51 RBC Elution Correction Calculator Medical devicesCr-51
What it does

Utility performs: Application of a protocol elution-correction factor to measured serial-sample activity. input.csv structure and numeric-value validation LabWare-compatible output.json generation

Why it is needed

Supports reproducible blood-cell labelling, free-activity control, cell viability and release before reinjection.

Where and when to use it

during autologous cell radiopharmaceutical preparation, labeling assessment and release before reinjection. Medical use: blood, cells and marrow.

Input fields

BatchNumber, SampleDay, MeasuredActivityKcpmPerMl, ElutionCorrectionFactor, ReferenceDay0ActivityKcpmPerMl, MinCorrectedRetentionPercent

Open utility

Related utilities
Cr-51 RBC Mass and Survival Analyzer Medical devicesCr-51
What it does

Utility performs: Calculation of labelled red-cell volume by indicator dilution and indicative T50 from serial samples. input.csv structure and numeric-value validation LabWare-compatible output.json generation

Why it is needed

Supports reproducible blood-cell labelling, free-activity control, cell viability and release before reinjection.

Where and when to use it

during autologous cell radiopharmaceutical preparation, labeling assessment and release before reinjection. Medical use: blood, cells and marrow.

Input fields

BatchNumber, NetInjectedActivityKcpm, Day0SampleActivityKcpmPerMl, Day1ActivityKcpmPerMl, Day14ActivityKcpmPerMl, SampleVolumeMl, VenousHematocritFraction, BodyHematocritCorrectionFactor, MinExpectedT50Days

Open utility

Related utilities
Cr-51 RBC Recovery Curve Analyzer Medical devicesCr-51
What it does

Utility performs: Review of serial-measurement monotonicity, log-linear fit quality, early loss and calculated T50. input.csv structure and numeric-value validation LabWare-compatible output.json generation

Why it is needed

Supports reproducible blood-cell labelling, free-activity control, cell viability and release before reinjection.

Where and when to use it

during autologous cell radiopharmaceutical preparation, labeling assessment and release before reinjection. Medical use: blood, cells and marrow. Workflow stages: imaging QC and quantitative interpretation.

Input fields

BatchNumber, Day1RetentionPercent, Day7RetentionPercent, Day14RetentionPercent, Day21RetentionPercent, CurveR2, MinExpectedT50Days, MaxEarlyLossPercent

Open utility

Related utilities
In-111 Platelet Recovery Checker Medical devicesIn-111Tc-99m
What it does

Utility performs: Calculation of early labelled-platelet recovery from injected activity, sample activity, blood volume and decay correction. input.csv structure and numeric-value validation LabWare-compatible output.json generation

Why it is needed

Supports reproducible blood-cell labelling, free-activity control, cell viability and release before reinjection.

Where and when to use it

during autologous cell radiopharmaceutical preparation, labeling assessment and release before reinjection. Medical use: blood, cells and marrow. Workflow stages: stability, storage, decay and waste.

Input fields

BatchNumber, InjectedActivityMBq, SampleActivityKBqPerMl, EstimatedBloodVolumeMl, DecayCorrectionFactor, MinExpectedRecoveryPercent, MaxExpectedRecoveryPercent

Open utility

Related utilities
WBC Labeling Efficiency Calculator Medical devicesTc-99m
What it does

Utility performs: Calculation of labelling efficiency from cell-bound and supernatant activity. input.csv structure and numeric-value validation LabWare-compatible output.json generation

Why it is needed

Supports reproducible blood-cell labelling, free-activity control, cell viability and release before reinjection.

Where and when to use it

during autologous cell radiopharmaceutical preparation, labeling assessment and release before reinjection. Medical use: blood, cells and marrow, lymphatic, infection and inflammation. Workflow stages: synthesis, labelling and kit reconstitution, product release QC, imaging QC and quantitative interpretation.

Input fields

BatchNumber, CellBoundActivityMBq, SupernatantActivityMBq, WashActivityMBq, MinLabelingEfficiencyPercent

Open utility

Related utilities
WBC Reinjection Release Checker Medical devicesTc-99m
What it does

Utility performs: Final review of identity, labelling efficiency, viability, free activity, aggregates and time to reinjection. input.csv structure and numeric-value validation LabWare-compatible output.json generation

Why it is needed

Supports reproducible blood-cell labelling, free-activity control, cell viability and release before reinjection.

Where and when to use it

during autologous cell radiopharmaceutical preparation, labeling assessment and release before reinjection. Medical use: blood, cells and marrow, lymphatic, infection and inflammation. Workflow stages: synthesis, labelling and kit reconstitution, product release QC, imaging QC and quantitative interpretation.

Input fields

BatchNumber, PatientIdentityConfirmedFlag, LabelingEfficiencyPercent, ViabilityPercent, FreeActivityPercent, AggregatePercent, SterilityTest, EndotoxinsEUPerVial, TimeToReinjectionMin

Open utility

Related utilities
Tc-99m pertechnetate and functional imaging 3

Pertechnetate as a standalone radiopharmaceutical and starting material: thyroid uptake, salivary glands, Meckel scan, gastric mucosa and generator/eluate control.

Open package

API / calculation and rule-based 1

Tc-99m Sodium Pertechnetate Quality Checker API / calculation and rule-basedTc-99m
What it does

Utility performs: Control of radiochemical and radionuclidic purity, Mo-99 breakthrough, aluminium, pH, sterility and endotoxins in generator eluate. input.csv structure and numeric-value validation LabWare-compatible output.json generation

Why it is needed

Supports sodium pertechnetate as a standalone radiopharmaceutical and functional studies of the thyroid, salivary glands and ectopic gastric mucosa.

Where and when to use it

when using generator-derived Tc-99m and functional thyroid, salivary-gland and ectopic-gastric-mucosa studies. Medical use: hepatobiliary and GI, endocrine, thyroid and NET. Workflow stages: product release QC, generators and isotope purity, imaging QC and quantitative interpretation.

Input fields

BatchNumber, RadiochemicalPurityPercent, RadionuclidicPurityPercent, Mo99BreakthroughMicroCiPerMilliCiTc99m, AluminumPPM, pH, EndotoxinsEUPerMl, SterilityTest, ActivityMBqPerMl

Open utility

Related utilities

Medical devices 2

Tc-99m Pertechnetate Salivary Gland Quality Checker Medical devicesTc-99m
What it does

Utility performs: Calculation of right and left parotid excretion fractions after stimulation and inter-side asymmetry. input.csv structure and numeric-value validation LabWare-compatible output.json generation

Why it is needed

Supports sodium pertechnetate as a standalone radiopharmaceutical and functional studies of the thyroid, salivary glands and ectopic gastric mucosa.

Where and when to use it

when using generator-derived Tc-99m and functional thyroid, salivary-gland and ectopic-gastric-mucosa studies. Medical use: hepatobiliary and GI, endocrine, thyroid and NET. Workflow stages: product release QC, imaging QC and quantitative interpretation.

Input fields

BatchNumber, RightPreStimCounts, RightPostStimCounts, LeftPreStimCounts, LeftPostStimCounts, BackgroundCounts, MinExpectedExcretionFractionPercent, MaxAllowedAsymmetryPercent

Open utility

Related utilities
Tc-99m Pertechnetate Thyroid Uptake Quality Checker Medical devicesTc-99m
What it does

Utility performs: Calculation of thyroid uptake from thyroid, background and standard counts with measurement-quality and protocol-range checks. input.csv structure and numeric-value validation LabWare-compatible output.json generation

Why it is needed

Supports sodium pertechnetate as a standalone radiopharmaceutical and functional studies of the thyroid, salivary glands and ectopic gastric mucosa.

Where and when to use it

when using generator-derived Tc-99m and functional thyroid, salivary-gland and ectopic-gastric-mucosa studies. Medical use: hepatobiliary and GI, endocrine, thyroid and NET. Workflow stages: product release QC, imaging QC and quantitative interpretation, stability, storage, decay and waste.

Input fields

BatchNumber, ThyroidCounts, NeckBackgroundCounts, StandardCounts, StandardBackgroundCounts, DecayCorrectionFactor, MinExpectedUptakePercent, MaxExpectedUptakePercent

Open utility

Related utilities
cardiac, bone and classic SPECT radiopharmaceuticals 7

Sestamibi, tetrofosmin, MDP, pyrophosphate, thallium and related quality checks for cardiology, bone imaging and classic SPECT protocols.

Open package

API / calculation and rule-based 7

Tc-99m MDP Bone Scan Quality Checker API / calculation and rule-basedTc-99m
What it does

Utility checks critical parameters of Tc-99m MDP: Radiochemical purity (≥90%) Free technetium (<5%) Colloidal technetium (<5%)

Why it is needed

Supports classic SPECT applications in which product quality must remain connected to acquisition quality and quantitative interpretation.

Where and when to use it

during cardiac and bone Tc-99m kit release, before SPECT/acquisition and when confirming data fitness for interpretation. Medical use: hepatobiliary and GI, endocrine, thyroid and NET, bone and musculoskeletal. Workflow stages: product release QC, generators and isotope purity, imaging QC and quantitative interpretation.

Input fields

BatchNumber, RadiochemicalPurityPercent, FreeTechnetiumPercent, HydrolyzedReducedTcPercent, pH, TimeSincePreparationMin, ActivityMBq, SterilityTest, EndotoxinsEU_per_mL

Open utility

Related utilities
Tc-99m Sestamibi Cardiac Quality Checker API / calculation and rule-basedTc-99m
What it does

Utility checks critical parameters of Tc-99m Sestamibi: Radiochemical purity (≥90%) Free technetium (<5%) Colloidal technetium (<5%)

Why it is needed

Supports classic SPECT applications in which product quality must remain connected to acquisition quality and quantitative interpretation.

Where and when to use it

during cardiac and bone Tc-99m kit release, before SPECT/acquisition and when confirming data fitness for interpretation. Medical use: hepatobiliary and GI, cardiovascular, endocrine, thyroid and NET. Workflow stages: synthesis, labelling and kit reconstitution, product release QC, imaging QC and quantitative interpretation.

Input fields

BatchNumber, RadiochemicalPurityPercent, FreeTechnetiumPercent, HydrolyzedReducedTcPercent, pH, TimeSincePreparationMin, ActivityMBq, SterilityTest, EndotoxinsEU_per_mL, HeatingCondition

Open utility

Related utilities
Tc99m MDP Quality Checker API / calculation and rule-basedTc-99m
What it does

Utility checks critical parameters of Tc-99m MDP: Radiochemical purity (≥95%) Free pertechnetate (≤5%) Colloidal technetium (≤5%)

Why it is needed

Supports classic SPECT applications in which product quality must remain connected to acquisition quality and quantitative interpretation.

Where and when to use it

during cardiac and bone Tc-99m kit release, before SPECT/acquisition and when confirming data fitness for interpretation. Medical use: hepatobiliary and GI, endocrine, thyroid and NET, bone and musculoskeletal. Workflow stages: product release QC, generators and isotope purity, imaging QC and quantitative interpretation.

Input fields

BatchNumber, TotalActivityMBq, RadiochemicalPurityPercent, FreePertechnetatePercent, ReducedHydrolyzedTcPercent, pH, EndotoxinsEU, SterilityTest, AluminumContentPPM, ProductType

Open utility

Related utilities
Tc99m Sestamibi Quality Checker API / calculation and rule-basedTc-99m
What it does

Utility checks critical parameters of Tc-99m Sestamibi: Radiochemical purity (≥90%) Free pertechnetate (≤5%) Colloidal technetium (≤5%)

Why it is needed

Supports classic SPECT applications in which product quality must remain connected to acquisition quality and quantitative interpretation.

Where and when to use it

during cardiac and bone Tc-99m kit release, before SPECT/acquisition and when confirming data fitness for interpretation. Medical use: hepatobiliary and GI, cardiovascular, endocrine, thyroid and NET. Workflow stages: synthesis, labelling and kit reconstitution, product release QC, generators and isotope purity.

Input fields

BatchNumber, TotalActivityMBq, RadiochemicalPurityPercent, FreePertechnetatePercent, ReducedHydrolyzedTcPercent, pH, EndotoxinsEU, SterilityTest, ReactionTimeMin, CoolingTimeMin

Open utility

Related utilities
Tc99m Tetrofosmin Quality Checker API / calculation and rule-basedTc-99m
What it does

Utility checks critical parameters of Tc-99m Tetrofosmin: Radiochemical purity (≥90%) Free pertechnetate (≤5%) Colloidal technetium (≤5%)

Why it is needed

Supports classic SPECT applications in which product quality must remain connected to acquisition quality and quantitative interpretation.

Where and when to use it

during cardiac and bone Tc-99m kit release, before SPECT/acquisition and when confirming data fitness for interpretation. Medical use: renal and urinary, pulmonary and ventilation, hepatobiliary and GI, cardiovascular, endocrine, thyroid and NET. Workflow stages: product release QC, generators and isotope purity, imaging QC and quantitative interpretation.

Input fields

BatchNumber, TotalActivityMBq, RadiochemicalPurityPercent, FreePertechnetatePercent, ReducedHydrolyzedTcPercent, pH, EndotoxinsEU, SterilityTest, ReactionTimeMin, TimeSincePreparationMin

Open utility

Related utilities
Technetium99m Pyrophosphate Checker API / calculation and rule-basedTc-99m
What it does

Utility checks critical parameters of Tc-99m PYP: Radiochemical purity (≥95%) Free pertechnetate (≤5%) Colloidal technetium (≤5%)

Why it is needed

Supports classic SPECT applications in which product quality must remain connected to acquisition quality and quantitative interpretation.

Where and when to use it

during cardiac and bone Tc-99m kit release, before SPECT/acquisition and when confirming data fitness for interpretation. Medical use: hepatobiliary and GI, cardiovascular, brain and CNS, endocrine, thyroid and NET, bone and musculoskeletal, oncology and theranostics. Workflow stages: product release QC, generators and isotope purity, imaging QC and quantitative interpretation.

Input fields

BatchNumber, TotalActivityMBq, RadiochemicalPurityPercent, FreePertechnetatePercent, ReducedHydrolyzedTcPercent, pH, EndotoxinsEU, SterilityTest, AluminumContentPPM, ProductType

Open utility

Related utilities
Thallium201 Chloride Quality Checker API / calculation and rule-basedTc-99mTl-201
What it does

Utility checks critical parameters of Thallium-201: Radionuclidic purity (≥99.5%) Thallium-200 impurity (≤0.5%) Thallium-202 impurity (≤0.5%)

Why it is needed

Supports classic SPECT applications in which product quality must remain connected to acquisition quality and quantitative interpretation.

Where and when to use it

during cardiac and bone Tc-99m kit release, before SPECT/acquisition and when confirming data fitness for interpretation. Medical use: pulmonary and ventilation, cardiovascular, brain and CNS, endocrine, thyroid and NET, oncology and theranostics. Workflow stages: product release QC, generators and isotope purity, imaging QC and quantitative interpretation.

Input fields

BatchNumber, TotalActivityMBq, RadionuclidicPurityPercent, Thallium200ImpurityPercent, Thallium202ImpurityPercent, RadiochemicalPurityPercent, pH, EndotoxinsEU, SterilityTest, HeavyMetalsPPM

Open utility

Related utilities
PET/SPECT oncology diagnostics and receptor imaging 26

F-18, Ga-68, Cu-64, Zr-89, In-111 and other diagnostic tracers: synthesis, purity, receptor targeting, immuno-PET and generator-based workflows.

Open package

API / calculation and rule-based 26

Aluminum Fluoride18 F Quality Checker API / calculation and rule-basedF-18
What it does

The utility checks RCP, free fluoride, residual aluminum, sterility, endotoxins. Does not use machine learning — rule-based logic only. AluminumFluoride18FQualityChecker.exe → demo mode AluminumFluoride18FQualityChecker.exe input.csv output.json → evaluate data

Why it is needed

Supports PET/SPECT oncology diagnostics and receptor imaging through identity, purity, stability, uptake and result-comparability checks.

Where and when to use it

during PET/SPECT diagnostic tracer release, after synthesis, before release and when comparing tracer-specific risks. Medical use: bone and musculoskeletal, oncology and theranostics. Workflow stages: synthesis, labelling and kit reconstitution, product release QC, generators and isotope purity.

Input fields

BatchNumber, Radiopharmaceutical, Radionuclidic_Purity_Percent, Radiochemical_Purity_Percent, Specific_Activity_GBq_umol, Free_Fluoride_Percent, Aluminum_Residue_ppm, Precursor_Residue_ppm, Ethanol_Content_Percent, Acetonitrile_Residue_ppm

Open utility

Related utilities
Carbon11 Choline Quality Checker API / calculation and rule-basedC-11
What it does

The utility checks RCP, residual DMAE, methyl iodide, sterility, endotoxins. Does not use machine learning — rule-based logic only. Carbon11CholineQualityChecker.exe → demo mode Carbon11CholineQualityChecker.exe input.csv output.json → evaluate data

Why it is needed

Supports PET/SPECT oncology diagnostics and receptor imaging through identity, purity, stability, uptake and result-comparability checks.

Where and when to use it

during PET/SPECT diagnostic tracer release, after synthesis, before release and when comparing tracer-specific risks. Medical use: oncology and theranostics. Workflow stages: synthesis, labelling and kit reconstitution, product release QC, generators and isotope purity.

Input fields

BatchNumber, Radionuclidic_Purity_Percent, Radiochemical_Purity_Percent, Specific_Activity_GBq_umol, Precursor_DMAE_ppm, Methyl_Iodide_Residue_ppm, Ethanol_Content_Percent, pH_Value, Osmolality_mOsm_kg, SterilityTest

Open utility

Related utilities
Carbon11 Methionine Quality Checker API / calculation and rule-basedC-11
What it does

The utility checks RCP, residual precursor, methyl iodide, sterility, endotoxins. Does not use machine learning — rule-based logic only. Carbon11MethionineQualityChecker.exe → demo mode Carbon11MethionineQualityChecker.exe input.csv output.json → evaluate data

Why it is needed

Supports PET/SPECT oncology diagnostics and receptor imaging through identity, purity, stability, uptake and result-comparability checks.

Where and when to use it

during PET/SPECT diagnostic tracer release, after synthesis, before release and when comparing tracer-specific risks. Medical use: oncology and theranostics. Workflow stages: synthesis, labelling and kit reconstitution, product release QC, generators and isotope purity.

Input fields

BatchNumber, Radionuclidic_Purity_Percent, Radiochemical_Purity_Percent, Specific_Activity_GBq_umol, Precursor_Residue_ppm, Methyl_Iodide_Residue_ppm, Solvent_Residue_ppm, pH_Value, Osmolality_mOsm_kg, SterilityTest

Open utility

Related utilities
Copper-64 Quality Checker API / calculation and rule-basedCu-64
What it does

The utility checks radiochemical purity, specific activity, Ni/Zn impurities, sterility, endotoxins. Does not use machine learning — rule-based logic only. Copper64QualityChecker.exe → demo mode Copper64QualityChecker.exe input.csv output.json → evaluate data

Why it is needed

Supports PET/SPECT oncology diagnostics and receptor imaging through identity, purity, stability, uptake and result-comparability checks.

Where and when to use it

during PET/SPECT diagnostic tracer release, after synthesis, before release and when comparing tracer-specific risks. Medical use: renal and urinary, hepatobiliary and GI, oncology and theranostics. Workflow stages: synthesis, labelling and kit reconstitution, product release QC, generators and isotope purity.

Input fields

BatchNumber, Radionuclidic_Purity_Percent, Radiochemical_Purity_Percent, Specific_Activity_GBq_umol, Nickel_Content_ppm, Zinc_Content_ppm, Iron_Content_ppm, Total_Metal_Impurities_ppm, pH_Value, Ethanol_Content_Percent

Open utility

Related utilities
Copper64 ATSM Quality Checker API / calculation and rule-basedCu-64
What it does

Utility checks critical parameters of [64Cu]Cu-ATSM: Radionuclidic purity (≥99.9%) Radiochemical purity (≥95%) Free Copper-64 impurity (≤2.0%)

Why it is needed

Supports PET/SPECT oncology diagnostics and receptor imaging through identity, purity, stability, uptake and result-comparability checks.

Where and when to use it

during PET/SPECT diagnostic tracer release, after synthesis, before release and when comparing tracer-specific risks. Medical use: renal and urinary, hepatobiliary and GI, cardiovascular, brain and CNS, oncology and theranostics. Workflow stages: product release QC, generators and isotope purity, imaging QC and quantitative interpretation.

Input fields

BatchNumber, RadionuclidicPurityPercent, RadiochemicalPurityPercent, FreeCopperPercent, ATSMLigandImpurityPercent, pH, EndotoxinsEU, SterilityTest, HeavyMetalsPPM, SpecificActivityGBqPerUmol

Open utility

Related utilities
Copper64 DOTATATE Quality Checker API / calculation and rule-basedCu-64Ga-68
What it does

Utility checks critical parameters of [64Cu]Cu-DOTATATE: Radionuclidic purity (≥99.9%) Radiochemical purity (≥95%) Free Copper-64 impurity (≤2.0%)

Why it is needed

Supports PET/SPECT oncology diagnostics and receptor imaging through identity, purity, stability, uptake and result-comparability checks.

Where and when to use it

during PET/SPECT diagnostic tracer release, after synthesis, before release and when comparing tracer-specific risks. Medical use: hepatobiliary and GI, brain and CNS, endocrine, thyroid and NET, oncology and theranostics. Workflow stages: synthesis, labelling and kit reconstitution, product release QC, generators and isotope purity.

Input fields

BatchNumber, RadionuclidicPurityPercent, RadiochemicalPurityPercent, FreeCopperPercent, DOTATATELigandImpurityPercent, pH, EndotoxinsEU, SterilityTest, HeavyMetalsPPM, SpecificActivityGBqPerUmol

Open utility

Related utilities
Copper64 Sarcophagine Quality Checker API / calculation and rule-basedCu-64
What it does

Utility checks critical parameters of [64Cu]Cu-Sarcophagine: Radionuclidic purity (≥99.9%) Radiochemical purity (≥98%) Free Copper-64 impurity (≤1.0%)

Why it is needed

Supports PET/SPECT oncology diagnostics and receptor imaging through identity, purity, stability, uptake and result-comparability checks.

Where and when to use it

during PET/SPECT diagnostic tracer release, after synthesis, before release and when comparing tracer-specific risks. Medical use: hepatobiliary and GI, endocrine, thyroid and NET, lymphatic, infection and inflammation, oncology and theranostics. Workflow stages: synthesis, labelling and kit reconstitution, product release QC, generators and isotope purity.

Input fields

BatchNumber, RadionuclidicPurityPercent, RadiochemicalPurityPercent, FreeCopperPercent, SarcophagineLigandImpurityPercent, pH, EndotoxinsEU, SterilityTest, HeavyMetalsPPM, SpecificActivityGBqPerUmol

Open utility

Related utilities
Fluorine18 Amyloid Quality Checker API / calculation and rule-basedF-18
What it does

Utility checks critical parameters of F-18 amyloid imaging agents (Florbetapir, Flutemetamol, Florbetaben): Radionuclidic purity (≥99.9%) Radiochemical purity (≥95%) Free Fluoride-18 impurity (≤5.0%)

Why it is needed

Supports PET/SPECT oncology diagnostics and receptor imaging through identity, purity, stability, uptake and result-comparability checks.

Where and when to use it

during PET/SPECT diagnostic tracer release, after synthesis, before release and when comparing tracer-specific risks. Medical use: hepatobiliary and GI, brain and CNS, bone and musculoskeletal, oncology and theranostics. Workflow stages: synthesis, labelling and kit reconstitution, product release QC, generators and isotope purity.

Input fields

BatchNumber, RadionuclidicPurityPercent, RadiochemicalPurityPercent, FreeFluoridePercent, PrecursorImpurityPercent, pH, EndotoxinsEU, SterilityTest, HeavyMetalsPPM, ResidualEthanolPercent

Open utility

Related utilities
Fluorine18 Choline Quality Checker API / calculation and rule-basedF-18
What it does

Utility checks critical parameters of [18F]Fluorocholine: Radionuclidic purity (≥99.9%) Radiochemical purity (≥95%) Free Fluoride-18 impurity (≤5.0%)

Why it is needed

Supports PET/SPECT oncology diagnostics and receptor imaging through identity, purity, stability, uptake and result-comparability checks.

Where and when to use it

during PET/SPECT diagnostic tracer release, after synthesis, before release and when comparing tracer-specific risks. Medical use: brain and CNS, bone and musculoskeletal, oncology and theranostics. Workflow stages: product release QC, generators and isotope purity, imaging QC and quantitative interpretation.

Input fields

BatchNumber, RadionuclidicPurityPercent, RadiochemicalPurityPercent, FreeFluoridePercent, PrecursorImpurityPercent, pH, EndotoxinsEU, SterilityTest, HeavyMetalsPPM, ResidualEthanolPercent

Open utility

Related utilities
Fluorine18 DOPA Quality Checker API / calculation and rule-basedF-18
What it does

Utility checks critical parameters of [18F]FDOPA: Radionuclidic purity (≥99.9%) Radiochemical purity (≥95%) Free Fluoride-18 impurity (≤5.0%)

Why it is needed

Supports PET/SPECT oncology diagnostics and receptor imaging through identity, purity, stability, uptake and result-comparability checks.

Where and when to use it

during PET/SPECT diagnostic tracer release, after synthesis, before release and when comparing tracer-specific risks. Medical use: brain and CNS, endocrine, thyroid and NET, bone and musculoskeletal, oncology and theranostics. Workflow stages: product release QC, generators and isotope purity, imaging QC and quantitative interpretation.

Input fields

BatchNumber, RadionuclidicPurityPercent, RadiochemicalPurityPercent, FreeFluoridePercent, PrecursorImpurityPercent, pH, EndotoxinsEU, SterilityTest, HeavyMetalsPPM, ResidualEthanolPercent

Open utility

Related utilities
Fluorine18 FDG Quality Checker API / calculation and rule-basedF-18
What it does

The utility checks specific activity, radiochemical purity, residual solvents (ethanol, acetonitrile), aluminium, pH, endotoxins, sterility, heavy metals. Does not use machine learning — rule-based logic only. Fluorine18FDGQualityChecker.exe → demo mode (console output) Fluorine18FDGQualityChecker.exe input.csv output.json → evaluate your data

Why it is needed

Supports PET/SPECT oncology diagnostics and receptor imaging through identity, purity, stability, uptake and result-comparability checks.

Where and when to use it

during PET/SPECT diagnostic tracer release, after synthesis, before release and when comparing tracer-specific risks. Medical use: hepatobiliary and GI, brain and CNS, oncology and theranostics. Workflow stages: synthesis, labelling and kit reconstitution, product release QC, imaging QC and quantitative interpretation.

Input fields

BatchNumber, SpecificActivityGBqPerUmol, RadiochemicalPurityPercent, ResidualEthanolPPM, ResidualAcetonitrilePPM, AluminiumPPM, pH, EndotoxinsEU, SterilityTest, HeavyMetalsPPM

Open utility

Related utilities
Fluorine18 FES Quality Checker API / calculation and rule-basedF-18
What it does

Utility checks critical parameters of [18F]Fluoroestradiol (FES): Radionuclidic purity (≥99.9%) Radiochemical purity (≥95%) Free Fluoride-18 impurity (≤5.0%)

Why it is needed

Supports PET/SPECT oncology diagnostics and receptor imaging through identity, purity, stability, uptake and result-comparability checks.

Where and when to use it

during PET/SPECT diagnostic tracer release, after synthesis, before release and when comparing tracer-specific risks. Medical use: bone and musculoskeletal, oncology and theranostics. Workflow stages: synthesis, labelling and kit reconstitution, product release QC, generators and isotope purity.

Input fields

BatchNumber, RadionuclidicPurityPercent, RadiochemicalPurityPercent, FreeFluoridePercent, PrecursorImpurityPercent, pH, EndotoxinsEU, SterilityTest, HeavyMetalsPPM, ResidualEthanolPercent

Open utility

Related utilities
Fluorine18 FLT Quality Checker API / calculation and rule-basedF-18
What it does

Utility checks critical parameters of [18F]FLT (3'-deoxy-3'-[18F]fluorothymidine): Radionuclidic purity (≥99.9%) Radiochemical purity (≥95%) Free Fluoride-18 impurity (≤5.0%)

Why it is needed

Supports PET/SPECT oncology diagnostics and receptor imaging through identity, purity, stability, uptake and result-comparability checks.

Where and when to use it

during PET/SPECT diagnostic tracer release, after synthesis, before release and when comparing tracer-specific risks. Medical use: brain and CNS, bone and musculoskeletal, lymphatic, infection and inflammation, oncology and theranostics. Workflow stages: synthesis, labelling and kit reconstitution, product release QC, generators and isotope purity.

Input fields

BatchNumber, RadionuclidicPurityPercent, RadiochemicalPurityPercent, FreeFluoridePercent, PrecursorImpurityPercent, pH, EndotoxinsEU, SterilityTest, HeavyMetalsPPM, ResidualEthanolPercent

Open utility

Related utilities
Fluorine18 FMISO Quality Checker API / calculation and rule-basedF-18
What it does

Utility checks critical parameters of [18F]FMISO (Fluoromisonidazole): Radionuclidic purity (≥99.9%) Radiochemical purity (≥95%) Free Fluoride-18 impurity (≤5.0%)

Why it is needed

Supports PET/SPECT oncology diagnostics and receptor imaging through identity, purity, stability, uptake and result-comparability checks.

Where and when to use it

during PET/SPECT diagnostic tracer release, after synthesis, before release and when comparing tracer-specific risks. Medical use: cardiovascular, brain and CNS, bone and musculoskeletal, oncology and theranostics. Workflow stages: product release QC, generators and isotope purity, imaging QC and quantitative interpretation.

Input fields

BatchNumber, RadionuclidicPurityPercent, RadiochemicalPurityPercent, FreeFluoridePercent, PrecursorImpurityPercent, pH, EndotoxinsEU, SterilityTest, HeavyMetalsPPM, ResidualEthanolPercent

Open utility

Related utilities
Fluorine18 Na F Quality Checker API / calculation and rule-basedF-18
What it does

The utility checks radiochemical purity (as [18F]fluoride), radionuclidic purity (F-18), aluminium, pH, endotoxins, sterility, heavy metals, residual ethanol. Does not use machine learning — rule-based logic only. Fluorine18NaFQualityChecker.exe → demo mode (console output)

Why it is needed

Supports PET/SPECT oncology diagnostics and receptor imaging through identity, purity, stability, uptake and result-comparability checks.

Where and when to use it

during PET/SPECT diagnostic tracer release, after synthesis, before release and when comparing tracer-specific risks. Medical use: pulmonary and ventilation, hepatobiliary and GI, bone and musculoskeletal, oncology and theranostics. Workflow stages: synthesis, labelling and kit reconstitution, product release QC, generators and isotope purity.

Input fields

BatchNumber, RadiochemicalPurityPercent, RadionuclidicPurityPercent, AluminiumPPM, pH, EndotoxinsEU, SterilityTest, HeavyMetalsPPM, ResidualEthanolPPM

Open utility

Related utilities
Fluorine18 PSMA Quality Checker API / calculation and rule-basedF-18
What it does

The utility checks specific activity, radiochemical purity, free ligand, pH, endotoxins, sterility, heavy metals, aluminium, residual ethanol. Does not use machine learning — rule-based logic only. Fluorine18PSMAQualityChecker.exe → demo mode (console output) Fluorine18PSMAQualityChecker.exe input.csv output.json → evaluate your data

Why it is needed

Supports PET/SPECT oncology diagnostics and receptor imaging through identity, purity, stability, uptake and result-comparability checks.

Where and when to use it

during PET/SPECT diagnostic tracer release, after synthesis, before release and when comparing tracer-specific risks. Medical use: hepatobiliary and GI, bone and musculoskeletal, oncology and theranostics. Workflow stages: synthesis, labelling and kit reconstitution, product release QC, dosimetry and therapy planning.

Input fields

BatchNumber, SpecificActivityGBqPerUmol, RadiochemicalPurityPercent, FreeLigandPercent, pH, EndotoxinsEU, SterilityTest, HeavyMetalsPPM, AluminiumPPM, ResidualEthanolPPM

Open utility

Related utilities
Gallium68 DOTATATE Quality Checker API / calculation and rule-basedGa-68
What it does

The utility checks specific activity, radiochemical purity, germanium-68 impurity, free peptide, pH, endotoxins, sterility, heavy metals, aluminium, residual solvents (ethanol, acetonitrile). Does not use machine learning — rule-based logic only. Gallium68DOTATATEQualityChecker.exe → demo mode (console output)

Why it is needed

Supports PET/SPECT oncology diagnostics and receptor imaging through identity, purity, stability, uptake and result-comparability checks.

Where and when to use it

during PET/SPECT diagnostic tracer release, after synthesis, before release and when comparing tracer-specific risks. Medical use: hepatobiliary and GI, brain and CNS, endocrine, thyroid and NET, bone and musculoskeletal, oncology and theranostics. Workflow stages: synthesis, labelling and kit reconstitution, product release QC, generators and isotope purity.

Input fields

BatchNumber, SpecificActivityGBqPerUmol, RadiochemicalPurityPercent, Germanium68ImpurityPercent, FreePeptidePercent, pH, EndotoxinsEU, SterilityTest, HeavyMetalsPPM, AluminiumPPM

Open utility

Related utilities
Gallium68 FAPI Quality Checker API / calculation and rule-basedGa-68
What it does

Utility checks quality of FAPI (Fibroblast Activation Protein Inhibitor) radiopharmaceutical: Specific activity (≥50 GBq/μmol) Radiochemical purity (≥95%) Germanium-68 impurity (≤0.001%)

Why it is needed

Supports PET/SPECT oncology diagnostics and receptor imaging through identity, purity, stability, uptake and result-comparability checks.

Where and when to use it

during PET/SPECT diagnostic tracer release, after synthesis, before release and when comparing tracer-specific risks. Medical use: hepatobiliary and GI, endocrine, thyroid and NET, bone and musculoskeletal, oncology and theranostics. Workflow stages: product release QC, imaging QC and quantitative interpretation, stability, storage, decay and waste.

Input fields

BatchNumber, SpecificActivityGBqPerUmol, RadiochemicalPurityPercent, Germanium68ImpurityPercent, FreeGallium68Percent, pH, EndotoxinsEU, SterilityTest, HeavyMetalsPPM, AluminiumPPM

Open utility

Related utilities
Gallium68 Generator Quality Checker API / calculation and rule-basedGa-68
What it does

Utility checks critical eluate parameters: germanium-68 breakthrough (calculated as % of Ga-68 activity), eluate volume, eluate pH, metallic impurities (aluminium, iron), endotoxins, sterility. Does not use machine learning — only mathematical calculation of breakthrough percentages and pharmacopoeial limit checks.

Why it is needed

Supports PET/SPECT oncology diagnostics and receptor imaging through identity, purity, stability, uptake and result-comparability checks.

Where and when to use it

during PET/SPECT diagnostic tracer release, after synthesis, before release and when comparing tracer-specific risks. Medical use: brain and CNS, endocrine, thyroid and NET, bone and musculoskeletal, oncology and theranostics. Workflow stages: synthesis, labelling and kit reconstitution, product release QC, generators and isotope purity.

Input fields

BatchNumber, Ga68ActivityMBq, Ge68ActivityMBq, EluateVolumeMl, EluatePH, AluminiumPPM, IronPPM, EndotoxinsEU, SterilityTest

Open utility

Related utilities
Gallium68 HBEDCC Quality Checker API / calculation and rule-basedGa-68
What it does

Utility checks critical parameters of [68Ga]Ga-PSMA-11 (HBED-CC): Radionuclidic purity (≥99.9%) Radiochemical purity (≥95%) Free Gallium-68 impurity (≤5.0%)

Why it is needed

Supports PET/SPECT oncology diagnostics and receptor imaging through identity, purity, stability, uptake and result-comparability checks.

Where and when to use it

during PET/SPECT diagnostic tracer release, after synthesis, before release and when comparing tracer-specific risks. Medical use: hepatobiliary and GI, bone and musculoskeletal, oncology and theranostics. Workflow stages: synthesis, labelling and kit reconstitution, product release QC, generators and isotope purity.

Input fields

BatchNumber, RadionuclidicPurityPercent, RadiochemicalPurityPercent, FreeGalliumPercent, PrecursorImpurityPercent, pH, EndotoxinsEU, SterilityTest, HeavyMetalsPPM, ResidualEthanolPercent

Open utility

Related utilities
Gallium68 LNP Tracker Quality Checker API / calculation and rule-basedGa-68
What it does

DEPRECATED UTILITY This utility has been REPLACED by the universal version: RadiolabeledNanoparticleQualityChecker.exe Please use the universal utility instead:

Why it is needed

Supports PET/SPECT oncology diagnostics and receptor imaging through identity, purity, stability, uptake and result-comparability checks.

Where and when to use it

during PET/SPECT diagnostic tracer release, after synthesis, before release and when comparing tracer-specific risks. Medical use: pulmonary and ventilation, oncology and theranostics. Workflow stages: product release QC, generators and isotope purity, stability, storage, decay and waste.

Input fields

BatchNumber, SpecificActivityGBqPerUmol, RadiochemicalPurityPercent, Germanium68ImpurityPercent, FreeGallium68Percent, ParticleSizeNm, ParticleSizePDI, pH, EndotoxinsEU, SterilityTest

Open utility

Related utilities
Gallium68 PSMA Quality Checker API / calculation and rule-basedGa-68
What it does

The utility checks specific activity, radiochemical purity, germanium-68 impurity, free ligand, pH, endotoxins, sterility, heavy metals, aluminium, residual solvents (ethanol, acetonitrile). Does not use machine learning — rule-based logic only. Gallium68PSMAQualityChecker.exe → demo mode (console output)

Why it is needed

Supports PET/SPECT oncology diagnostics and receptor imaging through identity, purity, stability, uptake and result-comparability checks.

Where and when to use it

during PET/SPECT diagnostic tracer release, after synthesis, before release and when comparing tracer-specific risks. Medical use: hepatobiliary and GI, brain and CNS, endocrine, thyroid and NET, bone and musculoskeletal, oncology and theranostics. Workflow stages: synthesis, labelling and kit reconstitution, product release QC, generators and isotope purity.

Input fields

BatchNumber, SpecificActivityGBqPerUmol, RadiochemicalPurityPercent, Germanium68ImpurityPercent, FreeLigandPercent, pH, EndotoxinsEU, SterilityTest, HeavyMetalsPPM, AluminiumPPM

Open utility

Related utilities
Indium111 Pentetreotide Quality Checker API / calculation and rule-basedIn-111
What it does

Utility checks critical parameters of the somatostatin analog radiopharmaceutical: Radiochemical purity (≥90%) Free Indium-111 impurity (≤5%) Colloidal Indium-111 impurity (≤5%)

Why it is needed

Supports PET/SPECT oncology diagnostics and receptor imaging through identity, purity, stability, uptake and result-comparability checks.

Where and when to use it

during PET/SPECT diagnostic tracer release, after synthesis, before release and when comparing tracer-specific risks. Medical use: renal and urinary, hepatobiliary and GI, brain and CNS, endocrine, thyroid and NET, bone and musculoskeletal, oncology and theranostics. Workflow stages: synthesis, labelling and kit reconstitution, product release QC, generators and isotope purity.

Input fields

BatchNumber, RadiochemicalPurityPercent, FreeIndium111Percent, ColloidalIndium111Percent, SpecificActivityMBqPerUg, pH, EndotoxinsEU, SterilityTest, HeavyMetalsPPM, PeptideConcentrationUgPerVial

Open utility

Related utilities
Nitrogen13 Ammonia Quality Checker API / calculation and rule-basedF-18N-13
What it does

Utility checks critical parameters of [13N]Ammonia: Radionuclidic purity (≥99.5%) Fluorine-18 impurity (≤0.1%) Radiochemical purity (≥95%)

Why it is needed

Supports PET/SPECT oncology diagnostics and receptor imaging through identity, purity, stability, uptake and result-comparability checks.

Where and when to use it

during PET/SPECT diagnostic tracer release, after synthesis, before release and when comparing tracer-specific risks. Medical use: cardiovascular, blood, cells and marrow, oncology and theranostics. Workflow stages: synthesis, labelling and kit reconstitution, product release QC, generators and isotope purity.

Input fields

BatchNumber, TotalActivityMBq, RadionuclidicPurityPercent, Fluorine18ImpurityPercent, RadiochemicalPurityPercent, NitrateNitritePercent, pH, EndotoxinsEU, SterilityTest, HeavyMetalsPPM

Open utility

Related utilities
Oxygen15 Water Quality Checker API / calculation and rule-basedF-18N-13O-15
What it does

Utility checks critical parameters of [15O]Water: Radionuclidic purity (≥99.5%) Nitrogen-13 impurity (≤1.0%) Fluorine-18 impurity (≤0.1%)

Why it is needed

Supports PET/SPECT oncology diagnostics and receptor imaging through identity, purity, stability, uptake and result-comparability checks.

Where and when to use it

during PET/SPECT diagnostic tracer release, after synthesis, before release and when comparing tracer-specific risks. Medical use: cardiovascular, brain and CNS, oncology and theranostics. Workflow stages: synthesis, labelling and kit reconstitution, product release QC, generators and isotope purity.

Input fields

BatchNumber, TotalActivityMBq, RadionuclidicPurityPercent, Nitrogen13ImpurityPercent, Fluorine18ImpurityPercent, RadiochemicalPurityPercent, pH, EndotoxinsEU, SterilityTest, HeavyMetalsPPM

Open utility

Related utilities
Scandium43 Quality Checker API / calculation and rule-basedGa-68
What it does

Utility checks critical parameters of Scandium-43: Radionuclidic purity (≥99.0%) Scandium-44 impurity (≤1.0%) Scandium-46 impurity (≤0.1%)

Why it is needed

Supports PET/SPECT oncology diagnostics and receptor imaging through identity, purity, stability, uptake and result-comparability checks.

Where and when to use it

during PET/SPECT diagnostic tracer release, after synthesis, before release and when comparing tracer-specific risks. Medical use: hepatobiliary and GI, brain and CNS, endocrine, thyroid and NET, bone and musculoskeletal, oncology and theranostics. Workflow stages: synthesis, labelling and kit reconstitution, product release QC, generators and isotope purity.

Input fields

BatchNumber, TotalActivityMBq, RadionuclidicPurityPercent, Scandium44ImpurityPercent, Scandium46ImpurityPercent, RadiochemicalPurityPercent, FreeScandiumPercent, pH, EndotoxinsEU, SterilityTest

Open utility

Related utilities
radionuclide therapy and theranostics 67

Lu-177, Ac-225, Ra-223, Y-90, Ho-166, Sm-153, Sr-89, Re-188, Tb-161, I-131 and other therapeutic radiopharmaceuticals: activity, purity, free metal, daughters and toxicological constraints.

Open package

API / calculation and rule-based 67

Ac-225 Targeted Alpha Therapy QC API / calculation and rule-basedAc-225
What it does

Utility checks critical parameters of Ac-225 radioligands: Radiochemical purity (≥95%) Free Ac-225 (≤2%) Daughter nuclides (<1%) — recoil effect control!

Why it is needed

Supports theranostics and radionuclide therapy as one chain covering release, daughter products, dosimetry and patient-safety controls.

Where and when to use it

during therapeutic radiopharmaceutical release, dosimetry planning, free-metal assessment, daughter radionuclide control and handling safety review. Medical use: renal and urinary, pulmonary and ventilation, hepatobiliary and GI, bone and musculoskeletal, oncology and theranostics. Workflow stages: synthesis, labelling and kit reconstitution, product release QC, generators and isotope purity.

Input fields

BatchNumber, RadiochemicalPurityPercent, FreeAc225Percent, DaughterNuclidesPercent, SpecificActivityGBq_per_mg, pH, EndotoxinsEU_per_mL, SterilityTest, ActivityMBq, RadionuclidicPurityPercent

Open utility

Related utilities
Ac225 Daughter Recoil Analyzer API / calculation and rule-basedAc-225Bi-213
What it does

Utility evaluates alpha-emitting product stability: Free Bi-213 percentage (≤2%) Fr-221/Ac-225 equilibrium Recoil energy (theoretical estimate)

Why it is needed

Supports theranostics and radionuclide therapy as one chain covering release, daughter products, dosimetry and patient-safety controls.

Where and when to use it

during therapeutic radiopharmaceutical release, dosimetry planning, free-metal assessment, daughter radionuclide control and handling safety review. Medical use: renal and urinary, bone and musculoskeletal, oncology and theranostics. Workflow stages: synthesis, labelling and kit reconstitution, stability, storage, decay and waste, instruments, devices and radiation safety.

Input fields

BatchNumber, ProductName, Activity_Ac225, Activity_Fr221, Activity_Bi213, Time_Hours, Max_Allowed_Free_Bi213_Percent

Open utility

Related utilities
Actinium225 Quality Checker API / calculation and rule-basedAc-225Bi-213
What it does

Utility checks critical parameters of actinium-225: Specific activity (≥500 MBq/μmol for conjugates) Radiochemical purity (≥95%) Free actinium (≤5% for conjugates)

Why it is needed

Supports theranostics and radionuclide therapy as one chain covering release, daughter products, dosimetry and patient-safety controls.

Where and when to use it

during therapeutic radiopharmaceutical release, dosimetry planning, free-metal assessment, daughter radionuclide control and handling safety review. Medical use: renal and urinary, hepatobiliary and GI, brain and CNS, endocrine, thyroid and NET, bone and musculoskeletal, oncology and theranostics. Workflow stages: synthesis, labelling and kit reconstitution, product release QC, dosimetry and therapy planning.

Input fields

BatchNumber, SpecificActivityMBqPerUmol, RadiochemicalPurityPercent, FreeActiniumPercent, Francium221ImpurityPercent, Astatine217ImpurityPercent, Bismuth213ImpurityPercent, Thallium209ImpurityPercent, pH, EndotoxinsEU

Open utility

Related utilities
Actinium225 Radioligand Checker API / calculation and rule-basedAc-225
What it does

Utility performs deterministic QC review for radioligand / theranostics products: Source priority: Ph. Eur. → British Pharmacopoeia / UK implementation → EAEU → EMA/ICH/EU guidance → USP fallback Strict API defaults when exact monograph is not yet encoded: Assay 98–102%, Total impurities ≤1.0%, Individual impurity ≤0.5%

Why it is needed

Supports theranostics and radionuclide therapy as one chain covering release, daughter products, dosimetry and patient-safety controls.

Where and when to use it

during therapeutic radiopharmaceutical release, dosimetry planning, free-metal assessment, daughter radionuclide control and handling safety review. Medical use: oncology and theranostics. Workflow stages: product release QC.

Input fields

BatchNumber, ProductName, SubstanceName, ProductClass, Assay_Percent, TotalImpurities_Percent, IndividualImpurityMax_Percent, Aggregates_Percent, Sterility_Result, Endotoxin_Value

Open utility

Related utilities
Astatine-211 Quality Checker API / calculation and rule-basedAt-211
What it does

Utility checks critical parameters of astatine-211: Radionuclidic purity (≥99.9%) Astatine-210 impurity (≤0.001%) — CRITICAL! Radiochemical purity (≥95%)

Why it is needed

Supports theranostics and radionuclide therapy as one chain covering release, daughter products, dosimetry and patient-safety controls.

Where and when to use it

during therapeutic radiopharmaceutical release, dosimetry planning, free-metal assessment, daughter radionuclide control and handling safety review. Medical use: hepatobiliary and GI, brain and CNS, endocrine, thyroid and NET, oncology and theranostics. Workflow stages: synthesis, labelling and kit reconstitution, product release QC, generators and isotope purity.

Input fields

BatchNumber, ActivityMBq, RadionuclidicPurityPercent, At210ImpurityPercent, RadiochemicalPurityPercent, FreeAstatinePercent, pH, EndotoxinsEU, SterilityTest, ProductType

Open utility

Related utilities
Bismuth-213 Quality Checker API / calculation and rule-basedBi-213
What it does

Utility checks critical parameters of bismuth-213: Radionuclidic purity (≥99.9%) Actinium-225 breakthrough (≤0.01%) — CRITICAL! (Generator leakage) Radiochemical purity (≥95%)

Why it is needed

Supports theranostics and radionuclide therapy as one chain covering release, daughter products, dosimetry and patient-safety controls.

Where and when to use it

during therapeutic radiopharmaceutical release, dosimetry planning, free-metal assessment, daughter radionuclide control and handling safety review. Medical use: renal and urinary, hepatobiliary and GI, brain and CNS, endocrine, thyroid and NET, bone and musculoskeletal, oncology and theranostics. Workflow stages: synthesis, labelling and kit reconstitution, product release QC, generators and isotope purity.

Input fields

BatchNumber, ActivityMBq, RadionuclidicPurityPercent, Ac225BreakthroughPercent, RadiochemicalPurityPercent, FreeBismuthPercent, pH, EndotoxinsEU, SterilityTest, ProductType

Open utility

Related utilities
Copper64 Radioligand Checker API / calculation and rule-basedCu-64
What it does

Utility performs deterministic QC review for radioligand / theranostics products: Source priority: Ph. Eur. → British Pharmacopoeia / UK implementation → EAEU → EMA/ICH/EU guidance → USP fallback Strict API defaults when exact monograph is not yet encoded: Assay 98–102%, Total impurities ≤1.0%, Individual impurity ≤0.5%

Why it is needed

Supports theranostics and radionuclide therapy as one chain covering release, daughter products, dosimetry and patient-safety controls.

Where and when to use it

during therapeutic radiopharmaceutical release, dosimetry planning, free-metal assessment, daughter radionuclide control and handling safety review. Medical use: oncology and theranostics. Workflow stages: product release QC.

Input fields

BatchNumber, ProductName, SubstanceName, ProductClass, Assay_Percent, TotalImpurities_Percent, IndividualImpurityMax_Percent, Aggregates_Percent, Sterility_Result, Endotoxin_Value

Open utility

Related utilities
Cu-64 ATSM Quality Checker API / calculation and rule-basedCu-64
What it does

Utility checks critical parameters of Cu-64 ATSM: Radiochemical purity (≥95%) Free copper (≤5%) Specific activity (≥10 GBq/umol)

Why it is needed

Supports theranostics and radionuclide therapy as one chain covering release, daughter products, dosimetry and patient-safety controls.

Where and when to use it

during therapeutic radiopharmaceutical release, dosimetry planning, free-metal assessment, daughter radionuclide control and handling safety review. Medical use: renal and urinary, hepatobiliary and GI, brain and CNS, oncology and theranostics. Workflow stages: synthesis, labelling and kit reconstitution, product release QC, generators and isotope purity.

Input fields

BatchNumber, RadiochemicalPurityPercent, FreeCopperPercent, SpecificActivityGBq_per_umol, pH, ResidualSolventsPPM, EndotoxinsEU_per_mL, SterilityTest, ActivityMBq, RadionuclidicPurityPercent

Open utility

Related utilities
Cu64 F18 Chelator Stability Monitor API / calculation and rule-basedCu-64F-18
What it does

Utility evaluates radiopharmaceutical resistance to decay/dissociation: Intact complex % (≥95%) Free isotope % (≤2%) Colloidal form % (≤1%)

Why it is needed

Supports theranostics and radionuclide therapy as one chain covering release, daughter products, dosimetry and patient-safety controls.

Where and when to use it

during therapeutic radiopharmaceutical release, dosimetry planning, free-metal assessment, daughter radionuclide control and handling safety review. Medical use: renal and urinary, hepatobiliary and GI, oncology and theranostics. Workflow stages: synthesis, labelling and kit reconstitution, stability, storage, decay and waste.

Input fields

BatchNumber, ProductName, Isotope, Intact_Complex_Percent, Free_Metal_Percent, Colloidal_Form_Percent, Challenge_Type, Incubation_Time_Hours, Temperature_C, Min_Intact_Percent

Open utility

Related utilities
F-18 PSMA PET Synthesis Quality Checker API / calculation and rule-basedF-18
What it does

Utility checks critical parameters of F-18 PSMA radioligands: Radiochemical purity (≥95%) Free fluoride (≤5%) Precursor residue (<0.1%)

Why it is needed

Supports theranostics and radionuclide therapy as one chain covering release, daughter products, dosimetry and patient-safety controls.

Where and when to use it

during therapeutic radiopharmaceutical release, dosimetry planning, free-metal assessment, daughter radionuclide control and handling safety review. Medical use: bone and musculoskeletal, oncology and theranostics. Workflow stages: synthesis, labelling and kit reconstitution, product release QC, generators and isotope purity.

Input fields

BatchNumber, RadiochemicalPurityPercent, FreeFluoridePercent, PrecursorPercent, SpecificActivityGBq_per_umol, pH, ResidualSolventsPPM, EndotoxinsEU_per_mL, SterilityTest, ActivityMBq

Open utility

Related utilities
Fluorine18 Radioligand Checker API / calculation and rule-basedF-18
What it does

Utility performs deterministic QC review for radioligand / theranostics products: Source priority: Ph. Eur. → British Pharmacopoeia / UK implementation → EAEU → EMA/ICH/EU guidance → USP fallback Strict API defaults when exact monograph is not yet encoded: Assay 98–102%, Total impurities ≤1.0%, Individual impurity ≤0.5%

Why it is needed

Supports theranostics and radionuclide therapy as one chain covering release, daughter products, dosimetry and patient-safety controls.

Where and when to use it

during therapeutic radiopharmaceutical release, dosimetry planning, free-metal assessment, daughter radionuclide control and handling safety review. Medical use: oncology and theranostics. Workflow stages: product release QC.

Input fields

BatchNumber, ProductName, SubstanceName, ProductClass, Assay_Percent, TotalImpurities_Percent, IndividualImpurityMax_Percent, Aggregates_Percent, Sterility_Result, Endotoxin_Value

Open utility

Related utilities
Ga-68 DOTATATE Generator Based QC API / calculation and rule-basedGa-68Ge-68
What it does

Utility checks critical parameters of Ga-68 DOTATATE: Radiochemical purity (≥95%) Free and colloidal Ga-68 (≤5% and <2%) Ge-68 breakthrough (<0.001%) — CRITICAL!

Why it is needed

Supports theranostics and radionuclide therapy as one chain covering release, daughter products, dosimetry and patient-safety controls.

Where and when to use it

during therapeutic radiopharmaceutical release, dosimetry planning, free-metal assessment, daughter radionuclide control and handling safety review. Medical use: hepatobiliary and GI, brain and CNS, endocrine, thyroid and NET, bone and musculoskeletal, oncology and theranostics. Workflow stages: synthesis, labelling and kit reconstitution, product release QC, generators and isotope purity.

Input fields

BatchNumber, RadiochemicalPurityPercent, FreeGalliumPercent, ColloidalGalliumPercent, SpecificActivityGBq_per_mg, pH, ResidualSolventsPPM, EndotoxinsEU_per_mL, SterilityTest, ActivityMBq

Open utility

Related utilities
Ho-166 Microsphere Quality Checker API / calculation and rule-basedHo-166
What it does

Utility checks critical parameters of Ho-166 microspheres: Radiochemical purity (≥98%) Free holmium (≤2%) Particle size (20-50 μm) and D90 (<60 μm)

Why it is needed

Supports theranostics and radionuclide therapy as one chain covering release, daughter products, dosimetry and patient-safety controls.

Where and when to use it

during therapeutic radiopharmaceutical release, dosimetry planning, free-metal assessment, daughter radionuclide control and handling safety review. Medical use: pulmonary and ventilation, hepatobiliary and GI, bone and musculoskeletal, oncology and theranostics. Workflow stages: product release QC, generators and isotope purity, dosimetry and therapy planning.

Input fields

BatchNumber, RadiochemicalPurityPercent, FreeHolmiumPercent, ParticleSizeMeanUm, ParticleSizeD90Um, SpecificActivityMBq_per_mg, pH, EndotoxinsEU_per_mL, SterilityTest, ActivityGBq

Open utility

Related utilities
Holmium-166 Quality Checker API / calculation and rule-basedHo-166
What it does

The utility checks particle size, RCP, free ions, sterility, endotoxins. Does not use machine learning — rule-based logic only. Holmium166QualityChecker.exe → demo mode Holmium166QualityChecker.exe input.csv output.json → evaluate data

Why it is needed

Supports theranostics and radionuclide therapy as one chain covering release, daughter products, dosimetry and patient-safety controls.

Where and when to use it

during therapeutic radiopharmaceutical release, dosimetry planning, free-metal assessment, daughter radionuclide control and handling safety review. Medical use: pulmonary and ventilation, hepatobiliary and GI, bone and musculoskeletal, oncology and theranostics. Workflow stages: product release QC, generators and isotope purity, imaging QC and quantitative interpretation.

Input fields

BatchNumber, Formulation_Type, Radionuclidic_Purity_Percent, Radiochemical_Purity_Percent, Specific_Activity_MBq_mg, Particle_Size_Mean_um, Particle_Size_Min_um, Particle_Size_Max_um, Particles_Out_of_Range_Percent, Free_Holmium_Ion_Percent

Open utility

Related utilities
I-131 Sodium Iodide Therapy QC API / calculation and rule-basedI-131
What it does

Utility checks critical parameters of I-131 NaI: Radiochemical purity (≥95%) Free iodine (≤5%) Volatile iodine forms (<1%) — RADIATION SAFETY!

Why it is needed

Supports theranostics and radionuclide therapy as one chain covering release, daughter products, dosimetry and patient-safety controls.

Where and when to use it

during therapeutic radiopharmaceutical release, dosimetry planning, free-metal assessment, daughter radionuclide control and handling safety review. Medical use: hepatobiliary and GI, endocrine, thyroid and NET, oncology and theranostics. Workflow stages: product release QC, generators and isotope purity, stability, storage, decay and waste.

Input fields

BatchNumber, RadiochemicalPurityPercent, FreeIodinePercent, pH, SpecificActivityMBq_per_mg, EndotoxinsEU_per_mL, SterilityTest, ActivityGBq, RadionuclidicPurityPercent, Te131ImpurityPercent

Open utility

Related utilities
I131 Iobenguane Commercial Radioligand Product Map API / calculation and rule-basedI-131
What it does

Utility checks critical parameters of I-131 MIBG radiopharmaceutical: Total Activity: Within specification Radiochemical Purity: ≥95.0% Free Iodide-131: ≤5.0%

Why it is needed

Supports theranostics and radionuclide therapy as one chain covering release, daughter products, dosimetry and patient-safety controls.

Where and when to use it

during therapeutic radiopharmaceutical release, dosimetry planning, free-metal assessment, daughter radionuclide control and handling safety review. Medical use: hepatobiliary and GI, brain and CNS, endocrine, thyroid and NET, oncology and theranostics. Workflow stages: product release QC, stability, storage, decay and waste, instruments, devices and radiation safety.

Input fields

BatchNumber, TotalActivityMBq, RCP, FreeIodide, ChemPurity, pH, Endotoxins, Sterility, SpecificActivity

Open utility

Related utilities
I131 Volatility Extended Checker API / calculation and rule-basedI-131
What it does

Utility performs DEEP analysis of volatile iodine with: Current value check (≤5.0%) Stability prediction until end of shelf life (60 days) Trend analysis with previous measurements

Why it is needed

Supports theranostics and radionuclide therapy as one chain covering release, daughter products, dosimetry and patient-safety controls.

Where and when to use it

during therapeutic radiopharmaceutical release, dosimetry planning, free-metal assessment, daughter radionuclide control and handling safety review. Medical use: oncology and theranostics. Workflow stages: product release QC, stability, storage, decay and waste.

Input fields

BatchNumber, VolatileIodinePercent_Current, MeasurementDateTime, ProductionDateTime, StorageTemperatureC, PreviousVolatileIodinePercent, PreviousMeasurementDateTime, HumidityPercent

Open utility

Related utilities
In-111 Octreotide Quality Checker API / calculation and rule-basedIn-111
What it does

Utility checks critical parameters of In-111 Octreotide: Radiochemical purity (≥95%) Free and colloidal In-111 (≤5% and <2%) Specific activity (≥20 MBq/mg)

Why it is needed

Supports theranostics and radionuclide therapy as one chain covering release, daughter products, dosimetry and patient-safety controls.

Where and when to use it

during therapeutic radiopharmaceutical release, dosimetry planning, free-metal assessment, daughter radionuclide control and handling safety review. Medical use: hepatobiliary and GI, brain and CNS, endocrine, thyroid and NET, bone and musculoskeletal, oncology and theranostics. Workflow stages: synthesis, labelling and kit reconstitution, product release QC, generators and isotope purity.

Input fields

BatchNumber, RadiochemicalPurityPercent, FreeIndiumPercent, ColloidalIndiumPercent, SpecificActivityMBq_per_mg, pH, ResidualSolventsPPM, EndotoxinsEU_per_mL, SterilityTest, ActivityMBq

Open utility

Related utilities
Iodine131 Capsules Quality Checker API / calculation and rule-basedI-131
What it does

The utility checks activity (% of declared), radiochemical purity, volatile iodine, disintegration, microbiology, heavy metals, residual solvents. Does not use machine learning — rule-based logic only. Iodine131CapsulesQualityChecker.exe → demo mode (console output) Iodine131CapsulesQualityChecker.exe input.csv output.json → evaluate your data

Why it is needed

Supports theranostics and radionuclide therapy as one chain covering release, daughter products, dosimetry and patient-safety controls.

Where and when to use it

during therapeutic radiopharmaceutical release, dosimetry planning, free-metal assessment, daughter radionuclide control and handling safety review. Medical use: hepatobiliary and GI, endocrine, thyroid and NET, oncology and theranostics. Workflow stages: product release QC, stability, storage, decay and waste, instruments, devices and radiation safety.

Input fields

BatchNumber, MeasuredActivityMBq, DeclaredActivityMBq, RadiochemicalPurity, VolatileIodine, DisintegrationTime, HeavyMetals, TAMC, TYMC, EColiDetected

Open utility

Related utilities
Iodine131 Hippuran Quality Checker API / calculation and rule-basedI-131
What it does

The source description did not contain a separate English section. The utility uses deterministic rule-based checks for Iodine-131 Hippuran using input.csv fields and generates output.json for QA/QC review. BatchNumber,RadiochemicalPurityPercent,FreeIodine131Percent,BenzoicAcidImpurityPercent,SpecificActivityMBqPerMg,pH,EndotoxinsEU,SterilityTest,TotalActivityMBq,AppearanceScore

Why it is needed

Supports theranostics and radionuclide therapy as one chain covering release, daughter products, dosimetry and patient-safety controls.

Where and when to use it

during therapeutic radiopharmaceutical release, dosimetry planning, free-metal assessment, daughter radionuclide control and handling safety review. Medical use: renal and urinary, oncology and theranostics. Workflow stages: product release QC, generators and isotope purity.

Input fields

BatchNumber, RadiochemicalPurityPercent, FreeIodine131Percent, BenzoicAcidImpurityPercent, SpecificActivityMBqPerMg, pH, EndotoxinsEU, SterilityTest, TotalActivityMBq, AppearanceScore

Open utility

Related utilities
Iodine131 Lipiodol Quality Checker API / calculation and rule-basedI-131
What it does

Utility checks critical parameters of Iodine-131 Lipiodol: Radionuclidic purity (≥99.9%) Iodine-125 impurity (≤0.1%) Radiochemical purity (≥95%) — binding to lipiodol

Why it is needed

Supports theranostics and radionuclide therapy as one chain covering release, daughter products, dosimetry and patient-safety controls.

Where and when to use it

during therapeutic radiopharmaceutical release, dosimetry planning, free-metal assessment, daughter radionuclide control and handling safety review. Medical use: hepatobiliary and GI, endocrine, thyroid and NET, oncology and theranostics. Workflow stages: product release QC, generators and isotope purity, imaging QC and quantitative interpretation.

Input fields

BatchNumber, TotalActivityMBq, RadionuclidicPurityPercent, Iodine125ImpurityPercent, RadiochemicalPurityPercent, FreeIodidePercent, pH, EndotoxinsEU, SterilityTest, HeavyMetalsPPM

Open utility

Related utilities
Iodine131 MIBG Quality Checker API / calculation and rule-basedI-131
What it does

Utility checks critical parameters of Iodine-131 MIBG: Radionuclidic purity (≥99.9%) Iodine-125 impurity (≤0.1%) Radiochemical purity (≥95%) — binding to MIBG

Why it is needed

Supports theranostics and radionuclide therapy as one chain covering release, daughter products, dosimetry and patient-safety controls.

Where and when to use it

during therapeutic radiopharmaceutical release, dosimetry planning, free-metal assessment, daughter radionuclide control and handling safety review. Medical use: brain and CNS, endocrine, thyroid and NET, oncology and theranostics. Workflow stages: product release QC, generators and isotope purity, imaging QC and quantitative interpretation.

Input fields

BatchNumber, TotalActivityMBq, RadionuclidicPurityPercent, Iodine125ImpurityPercent, RadiochemicalPurityPercent, FreeIodidePercent, PrecursorMIBGPercent, pH, EndotoxinsEU, SterilityTest

Open utility

Related utilities
Lead212 Quality Checker API / calculation and rule-basedGeneral RPH
What it does

Utility checks critical parameters of lead-212: Specific activity (≥100 MBq/μmol for conjugates) Radiochemical purity (≥95%) Daughter nuclides: bismuth-212 (≤5%), thallium-208 (≤1%)

Why it is needed

Supports theranostics and radionuclide therapy as one chain covering release, daughter products, dosimetry and patient-safety controls.

Where and when to use it

during therapeutic radiopharmaceutical release, dosimetry planning, free-metal assessment, daughter radionuclide control and handling safety review. Medical use: renal and urinary, hepatobiliary and GI, brain and CNS, endocrine, thyroid and NET, oncology and theranostics. Workflow stages: synthesis, labelling and kit reconstitution, product release QC, dosimetry and therapy planning.

Input fields

BatchNumber, SpecificActivityMBqPerUmol, RadiochemicalPurityPercent, Bismuth212ImpurityPercent, Thallium208ImpurityPercent, FreeLeadPercent, pH, EndotoxinsEU, SterilityTest, HeavyMetalsPPM

Open utility

Related utilities
Lu-177 DOTATATE Therapy Quality Checker API / calculation and rule-basedLu-177
What it does

Utility checks critical parameters of Lu-177 DOTATATE: Radiochemical purity (≥95%) Free lutetium (≤2%) Precursor residue (<0.1%)

Why it is needed

Supports theranostics and radionuclide therapy as one chain covering release, daughter products, dosimetry and patient-safety controls.

Where and when to use it

during therapeutic radiopharmaceutical release, dosimetry planning, free-metal assessment, daughter radionuclide control and handling safety review. Medical use: renal and urinary, hepatobiliary and GI, brain and CNS, endocrine, thyroid and NET, bone and musculoskeletal, oncology and theranostics. Workflow stages: synthesis, labelling and kit reconstitution, product release QC, generators and isotope purity.

Input fields

BatchNumber, RadiochemicalPurityPercent, FreeLutetiumPercent, PrecursorPercent, SpecificActivityGBq_per_mg, pH, ResidualSolventsPPM, EndotoxinsEU_per_mL, SterilityTest, ActivityGBq

Open utility

Related utilities
Lu-177 PSMA Therapy Quality Checker API / calculation and rule-basedLu-177
What it does

Utility checks critical parameters of Lu-177 PSMA: Radiochemical purity (≥95%) Free lutetium (≤2%) Precursor residue (<0.1%)

Why it is needed

Supports theranostics and radionuclide therapy as one chain covering release, daughter products, dosimetry and patient-safety controls.

Where and when to use it

during therapeutic radiopharmaceutical release, dosimetry planning, free-metal assessment, daughter radionuclide control and handling safety review. Medical use: renal and urinary, hepatobiliary and GI, bone and musculoskeletal, oncology and theranostics. Workflow stages: synthesis, labelling and kit reconstitution, product release QC, generators and isotope purity.

Input fields

BatchNumber, RadiochemicalPurityPercent, FreeLutetiumPercent, PrecursorPercent, SpecificActivityGBq_per_mg, pH, ResidualSolventsPPM, EndotoxinsEU_per_mL, SterilityTest, ActivityGBq

Open utility

Related utilities
Lu177 Dotatate Variants Commercial Radioligand Product Map API / calculation and rule-basedLu-177
What it does

Utility checks critical parameters of lutetium-177 dotatate: Radiochemical purity (≥95%) Free Lu-177 (≤2%) Colloidal Lu-177 (≤1%)

Why it is needed

Supports theranostics and radionuclide therapy as one chain covering release, daughter products, dosimetry and patient-safety controls.

Where and when to use it

during therapeutic radiopharmaceutical release, dosimetry planning, free-metal assessment, daughter radionuclide control and handling safety review. Medical use: hepatobiliary and GI, brain and CNS, endocrine, thyroid and NET, bone and musculoskeletal, oncology and theranostics. Workflow stages: product release QC, generators and isotope purity, imaging QC and quantitative interpretation.

Input fields

BatchNumber, CommercialProduct, RadiochemicalPurityPercent, FreeLu177Percent, ColloidalLu177Percent, SpecificActivityGBqPerUmol, pH, EndotoxinsEUPerVial, SterilityTest, RadionuclidicPurityPercent

Open utility

Related utilities
Lu177 Oxidation Checker API / calculation and rule-basedLu-177
What it does

Utility performs DEEP analysis of lutetium-177 oxidation with: Current Lu-177m impurity check (≤0.1%) Stability prediction until end of shelf life (7 days) Trend analysis with previous measurements

Why it is needed

Supports theranostics and radionuclide therapy as one chain covering release, daughter products, dosimetry and patient-safety controls.

Where and when to use it

during therapeutic radiopharmaceutical release, dosimetry planning, free-metal assessment, daughter radionuclide control and handling safety review. Medical use: endocrine, thyroid and NET, bone and musculoskeletal, oncology and theranostics. Workflow stages: product release QC, imaging QC and quantitative interpretation, stability, storage, decay and waste.

Input fields

BatchNumber, Lu177mImpurityPercent_Current, MeasurementDateTime, ProductionDateTime, ProductType, StorageTemperatureC, ProtectedFromLight, PreviousLu177mImpurityPercent, PreviousMeasurementDateTime

Open utility

Related utilities
Lu177 Vipivotide Tetraxetan Commercial Radioligand Product Map API / calculation and rule-basedLu-177
What it does

Utility checks critical parameters of lutetium-177 vipivotide tetraxetan: Radiochemical purity (≥95%) Free Lu-177 (≤2%) Colloidal Lu-177 (≤1%)

Why it is needed

Supports theranostics and radionuclide therapy as one chain covering release, daughter products, dosimetry and patient-safety controls.

Where and when to use it

during therapeutic radiopharmaceutical release, dosimetry planning, free-metal assessment, daughter radionuclide control and handling safety review. Medical use: hepatobiliary and GI, bone and musculoskeletal, oncology and theranostics. Workflow stages: product release QC, generators and isotope purity, imaging QC and quantitative interpretation.

Input fields

BatchNumber, CommercialProduct, RadiochemicalPurityPercent, FreeLu177Percent, ColloidalLu177Percent, SpecificActivityGBqPerUmol, pH, EndotoxinsEUPerVial, SterilityTest, RadionuclidicPurityPercent

Open utility

Related utilities
Lutetium177 DOTATATE Quality Checker API / calculation and rule-basedLu-177
What it does

The utility checks specific activity, radiochemical purity, impurities (177ᵐLu, free peptide), endotoxins, sterility, pH, heavy metals, residual solvents. Does not use machine learning — rule-based logic only. Lutetium177DOTATATEQualityChecker.exe → demo mode (console output)

Why it is needed

Supports theranostics and radionuclide therapy as one chain covering release, daughter products, dosimetry and patient-safety controls.

Where and when to use it

during therapeutic radiopharmaceutical release, dosimetry planning, free-metal assessment, daughter radionuclide control and handling safety review. Medical use: hepatobiliary and GI, brain and CNS, endocrine, thyroid and NET, oncology and theranostics. Workflow stages: product release QC, stability, storage, decay and waste.

Input fields

BatchNumber, SpecificActivityGBqPerUmol, RadiochemicalPurityPercent, Impurity177mLuPercent, FreePeptidePercent, EndotoxinsEU, SterilityTest, HeavyMetalsPPM, pH, EthanolPPM

Open utility

Related utilities
Lutetium177 DOTATOC Quality Checker API / calculation and rule-basedLu-177
What it does

Utility checks critical parameters of Lutetium-177 DOTATOC: Radionuclidic purity (≥99.9%) Lutetium-177m impurity (≤0.01%) Radiochemical purity (≥95%) — binding to DOTATOC

Why it is needed

Supports theranostics and radionuclide therapy as one chain covering release, daughter products, dosimetry and patient-safety controls.

Where and when to use it

during therapeutic radiopharmaceutical release, dosimetry planning, free-metal assessment, daughter radionuclide control and handling safety review. Medical use: hepatobiliary and GI, brain and CNS, endocrine, thyroid and NET, bone and musculoskeletal, oncology and theranostics. Workflow stages: synthesis, labelling and kit reconstitution, product release QC, generators and isotope purity.

Input fields

BatchNumber, TotalActivityMBq, RadionuclidicPurityPercent, Lutetium177mImpurityPercent, RadiochemicalPurityPercent, FreeLutetiumPercent, PrecursorPeptidePercent, pH, EndotoxinsEU, SterilityTest

Open utility

Related utilities
Lutetium177 J591 Quality Checker API / calculation and rule-basedLu-177
What it does

Utility checks critical parameters of Lutetium-177 J591: Radionuclidic purity (≥99.9%) Lutetium-177m impurity (≤0.01%) Radiochemical purity (≥95%) — binding to J591 monoclonal antibody

Why it is needed

Supports theranostics and radionuclide therapy as one chain covering release, daughter products, dosimetry and patient-safety controls.

Where and when to use it

during therapeutic radiopharmaceutical release, dosimetry planning, free-metal assessment, daughter radionuclide control and handling safety review. Medical use: renal and urinary, hepatobiliary and GI, bone and musculoskeletal, oncology and theranostics. Workflow stages: synthesis, labelling and kit reconstitution, product release QC, generators and isotope purity.

Input fields

BatchNumber, TotalActivityMBq, RadionuclidicPurityPercent, Lutetium177mImpurityPercent, RadiochemicalPurityPercent, FreeLutetiumPercent, AggregateContentPercent, ProteinConcentrationMgPerMl, pH, EndotoxinsEU

Open utility

Related utilities
Lutetium177 PSMA Quality Checker API / calculation and rule-basedLu-177
What it does

The utility checks specific activity, radiochemical purity, free ligand, endotoxins, sterility, pH, heavy metals, residual solvents. Does not use machine learning — rule-based logic only. Lutetium177PSMAQualityChecker.exe → demo mode (console output) Lutetium177PSMAQualityChecker.exe input.csv output.json → evaluate your data

Why it is needed

Supports theranostics and radionuclide therapy as one chain covering release, daughter products, dosimetry and patient-safety controls.

Where and when to use it

during therapeutic radiopharmaceutical release, dosimetry planning, free-metal assessment, daughter radionuclide control and handling safety review. Medical use: renal and urinary, hepatobiliary and GI, endocrine, thyroid and NET, oncology and theranostics. Workflow stages: product release QC, stability, storage, decay and waste.

Input fields

BatchNumber, SpecificActivityGBqPerUmol, RadiochemicalPurityPercent, FreeLigandPercent, EndotoxinsEU, SterilityTest, HeavyMetalsPPM, pH, EthanolPPM, AcetonePPM

Open utility

Related utilities
PSMA SSTR Radioligand Map Utility API / calculation and rule-basedGeneral RPH
What it does

Utility creates comprehensive quality map for targeted products: Structural integrity (urea bond/oxidation) Binding affinity (Kd, IC50) Free ligand and hydrolysis impurities

Why it is needed

Supports theranostics and radionuclide therapy as one chain covering release, daughter products, dosimetry and patient-safety controls.

Where and when to use it

during therapeutic radiopharmaceutical release, dosimetry planning, free-metal assessment, daughter radionuclide control and handling safety review. Medical use: oncology and theranostics. Workflow stages: synthesis, labelling and kit reconstitution, product release QC, stability, storage, decay and waste.

Input fields

BatchNumber, ProductName, TargetType, Urea_Linkage_Intact_Percent, Peptide_Oxidation_Percent, Kd_nM, Bmax_fmol_mg, IC50_nM, Free_Ligand_Percent, Hydrolysis_Product_Percent

Open utility

Related utilities
PSMARadioligand Release Checker API / calculation and rule-basedGeneral RPH
What it does

Utility performs deterministic QC review for radioligand / theranostics products: Source priority: Ph. Eur. → British Pharmacopoeia / UK implementation → EAEU → EMA/ICH/EU guidance → USP fallback Strict API defaults when exact monograph is not yet encoded: Assay 98–102%, Total impurities ≤1.0%, Individual impurity ≤0.5%

Why it is needed

Supports theranostics and radionuclide therapy as one chain covering release, daughter products, dosimetry and patient-safety controls.

Where and when to use it

during therapeutic radiopharmaceutical release, dosimetry planning, free-metal assessment, daughter radionuclide control and handling safety review. Medical use: oncology and theranostics. Workflow stages: product release QC.

Input fields

BatchNumber, ProductName, SubstanceName, ProductClass, Assay_Percent, TotalImpurities_Percent, IndividualImpurityMax_Percent, Aggregates_Percent, Sterility_Result, Endotoxin_Value

Open utility

Related utilities
Ra-223 Dichloride Injection QC API / calculation and rule-basedRa-223
What it does

Utility checks critical parameters of Ra-223 Dichloride: Radionuclidic purity (≥99.9%) Ac-227 impurity (<0.001%) — CRITICAL! Ra-224 impurity (<0.01%)

Why it is needed

Supports theranostics and radionuclide therapy as one chain covering release, daughter products, dosimetry and patient-safety controls.

Where and when to use it

during therapeutic radiopharmaceutical release, dosimetry planning, free-metal assessment, daughter radionuclide control and handling safety review. Medical use: pulmonary and ventilation, hepatobiliary and GI, bone and musculoskeletal, oncology and theranostics. Workflow stages: synthesis, labelling and kit reconstitution, product release QC, generators and isotope purity.

Input fields

BatchNumber, RadionuclidicPurityPercent, Ac227ImpurityPercent, Ra224ImpurityPercent, RadiochemicalPurityPercent, pH, Osmolality_mOsm_per_kg, EndotoxinsEU_per_mL, SterilityTest, ActivitykBq_per_mL

Open utility

Related utilities
Radiochemical Purity Profile Checker API / calculation and rule-basedGeneral RPH
What it does

Utility performs deterministic QC review for radioligand / theranostics products: Source priority: Ph. Eur. → British Pharmacopoeia / UK implementation → EAEU → EMA/ICH/EU guidance → USP fallback Strict API defaults when exact monograph is not yet encoded: Assay 98–102%, Total impurities ≤1.0%, Individual impurity ≤0.5%

Why it is needed

Supports theranostics and radionuclide therapy as one chain covering release, daughter products, dosimetry and patient-safety controls.

Where and when to use it

during therapeutic radiopharmaceutical release, dosimetry planning, free-metal assessment, daughter radionuclide control and handling safety review. Medical use: oncology and theranostics. Workflow stages: product release QC.

Input fields

BatchNumber, ProductName, SubstanceName, ProductClass, Assay_Percent, TotalImpurities_Percent, IndividualImpurityMax_Percent, Aggregates_Percent, Sterility_Result, Endotoxin_Value

Open utility

Related utilities
Radioligand Molar Activity Checker API / calculation and rule-basedGeneral RPH
What it does

Utility performs deterministic QC review for radioligand / theranostics products: Source priority: Ph. Eur. → British Pharmacopoeia / UK implementation → EAEU → EMA/ICH/EU guidance → USP fallback Strict API defaults when exact monograph is not yet encoded: Assay 98–102%, Total impurities ≤1.0%, Individual impurity ≤0.5%

Why it is needed

Supports theranostics and radionuclide therapy as one chain covering release, daughter products, dosimetry and patient-safety controls.

Where and when to use it

during therapeutic radiopharmaceutical release, dosimetry planning, free-metal assessment, daughter radionuclide control and handling safety review. Medical use: oncology and theranostics. Workflow stages: product release QC.

Input fields

BatchNumber, ProductName, SubstanceName, ProductClass, Assay_Percent, TotalImpurities_Percent, IndividualImpurityMax_Percent, Aggregates_Percent, Sterility_Result, Endotoxin_Value

Open utility

Related utilities
Radioligand Stability Trend Checker API / calculation and rule-basedGeneral RPH
What it does

Utility performs deterministic QC review for radioligand / theranostics products: Source priority: Ph. Eur. → British Pharmacopoeia / UK implementation → EAEU → EMA/ICH/EU guidance → USP fallback Strict API defaults when exact monograph is not yet encoded: Assay 98–102%, Total impurities ≤1.0%, Individual impurity ≤0.5%

Why it is needed

Supports theranostics and radionuclide therapy as one chain covering release, daughter products, dosimetry and patient-safety controls.

Where and when to use it

during therapeutic radiopharmaceutical release, dosimetry planning, free-metal assessment, daughter radionuclide control and handling safety review. Medical use: oncology and theranostics. Workflow stages: product release QC, stability, storage, decay and waste.

Input fields

BatchNumber, ProductName, SubstanceName, ProductClass, Assay_Percent, TotalImpurities_Percent, IndividualImpurityMax_Percent, Aggregates_Percent, Sterility_Result, Endotoxin_Value

Open utility

Related utilities
Radiolysis Stability Checker API / calculation and rule-basedGeneral RPH
What it does

Predicts RCP drop due to autoradiolysis based on activity, volume, and time. Accounts for radioprotectors (ascorbate, ethanol). RadiolysisStabilityChecker.exe → demo mode RadiolysisStabilityChecker.exe input.csv output.json → calculation

Why it is needed

Supports theranostics and radionuclide therapy as one chain covering release, daughter products, dosimetry and patient-safety controls.

Where and when to use it

during therapeutic radiopharmaceutical release, dosimetry planning, free-metal assessment, daughter radionuclide control and handling safety review. Medical use: endocrine, thyroid and NET, oncology and theranostics. Workflow stages: product release QC, generators and isotope purity, stability, storage, decay and waste.

Input fields

BatchNumber, Radiopharmaceutical, Initial_Activity_MBq, Volume_mL, Initial_RCP_Percent, Has_Radioprotector, Radioprotector_Type, Radioprotector_Concentration_mM, EOS_Time_ISO, Check_Time_ISO

Open utility

Related utilities
Radionuclidic Purity Checker API / calculation and rule-basedGeneral RPH
What it does

Utility performs deterministic QC review for radioligand / theranostics products: Source priority: Ph. Eur. → British Pharmacopoeia / UK implementation → EAEU → EMA/ICH/EU guidance → USP fallback Strict API defaults when exact monograph is not yet encoded: Assay 98–102%, Total impurities ≤1.0%, Individual impurity ≤0.5%

Why it is needed

Supports theranostics and radionuclide therapy as one chain covering release, daughter products, dosimetry and patient-safety controls.

Where and when to use it

during therapeutic radiopharmaceutical release, dosimetry planning, free-metal assessment, daughter radionuclide control and handling safety review. Medical use: oncology and theranostics. Workflow stages: product release QC, generators and isotope purity.

Input fields

BatchNumber, ProductName, SubstanceName, ProductClass, Assay_Percent, TotalImpurities_Percent, IndividualImpurityMax_Percent, Aggregates_Percent, Sterility_Result, Endotoxin_Value

Open utility

Related utilities
Radium223 Dichloride Quality Checker API / calculation and rule-basedRa-223
What it does

The utility checks activity, radiochemical purity, radon-222 impurity, pH, chlorides, endotoxins, sterility, heavy metals, residual solvents. Does not use machine learning — rule-based logic only. Radium223DichlorideQualityChecker.exe → demo mode (console output) Radium223DichlorideQualityChecker.exe input.csv output.json → evaluate your data

Why it is needed

Supports theranostics and radionuclide therapy as one chain covering release, daughter products, dosimetry and patient-safety controls.

Where and when to use it

during therapeutic radiopharmaceutical release, dosimetry planning, free-metal assessment, daughter radionuclide control and handling safety review. Medical use: hepatobiliary and GI, bone and musculoskeletal, oncology and theranostics. Workflow stages: product release QC, stability, storage, decay and waste, instruments, devices and radiation safety.

Input fields

BatchNumber, ActivityMBqPerMl, RadiochemicalPurityPercent, Radon222ImpurityBqPerMl, pH, ChloridesMgPerMl, EndotoxinsEU, SterilityTest, HeavyMetalsPPM, EthanolPPM

Open utility

Related utilities
Rapid Release Sterility Endotoxin Checker API / calculation and rule-basedGeneral RPH
What it does

Utility performs deterministic QC review for radioligand / theranostics products: Source priority: Ph. Eur. → British Pharmacopoeia / UK implementation → EAEU → EMA/ICH/EU guidance → USP fallback Strict API defaults when exact monograph is not yet encoded: Assay 98–102%, Total impurities ≤1.0%, Individual impurity ≤0.5%

Why it is needed

Supports theranostics and radionuclide therapy as one chain covering release, daughter products, dosimetry and patient-safety controls.

Where and when to use it

during therapeutic radiopharmaceutical release, dosimetry planning, free-metal assessment, daughter radionuclide control and handling safety review. Medical use: oncology and theranostics. Workflow stages: product release QC.

Input fields

BatchNumber, ProductName, SubstanceName, ProductClass, Assay_Percent, TotalImpurities_Percent, IndividualImpurityMax_Percent, Aggregates_Percent, Sterility_Result, Endotoxin_Value

Open utility

Related utilities
Re-188 Liposome Quality Checker API / calculation and rule-basedRe-188
What it does

Utility checks critical parameters of Re-188 Liposomes: Radiochemical purity (≥95%) Encapsulation efficiency (≥90%) Particle size (100-200 nm) and PDI (<0.2)

Why it is needed

Supports theranostics and radionuclide therapy as one chain covering release, daughter products, dosimetry and patient-safety controls.

Where and when to use it

during therapeutic radiopharmaceutical release, dosimetry planning, free-metal assessment, daughter radionuclide control and handling safety review. Medical use: bone and musculoskeletal, oncology and theranostics. Workflow stages: product release QC, generators and isotope purity, imaging QC and quantitative interpretation.

Input fields

BatchNumber, RadiochemicalPurityPercent, FreeRheniumPercent, EncapsulationEfficiencyPercent, ParticleSizeMeanNm, PolydispersityIndex, pH, Osmolality_mOsm_per_kg, EndotoxinsEU_per_mL, SterilityTest

Open utility

Related utilities
Rhenium-188 Quality Checker API / calculation and rule-basedRe-188
What it does

The utility checks W-188 breakthrough, RCP, free perrhenate, sterility. Does not use machine learning — rule-based logic only. Rhenium188QualityChecker.exe → demo mode Rhenium188QualityChecker.exe input.csv output.json → evaluate data

Why it is needed

Supports theranostics and radionuclide therapy as one chain covering release, daughter products, dosimetry and patient-safety controls.

Where and when to use it

during therapeutic radiopharmaceutical release, dosimetry planning, free-metal assessment, daughter radionuclide control and handling safety review. Medical use: hepatobiliary and GI, endocrine, thyroid and NET, bone and musculoskeletal, oncology and theranostics. Workflow stages: product release QC, generators and isotope purity.

Input fields

BatchNumber, Formulation_Type, Radionuclidic_Purity_Percent, Tungsten_188_Breakthrough_ppm, Radiochemical_Purity_Percent, Free_Perrhenate_Percent, Hydrolyzed_Reduced_Re_Percent, Specific_Activity_MBq_mg, pH_Value, Ethanol_Content_Percent

Open utility

Related utilities
Samarium153 EDTMP Quality Checker API / calculation and rule-basedSm-153Tc-99m
What it does

Utility checks critical parameters of Samarium-153 EDTMP: Radionuclidic purity (≥99.9%) Europium-154/155 impurities (≤0.1%) — LONG-LIVED! Radiochemical purity (≥95%)

Why it is needed

Supports theranostics and radionuclide therapy as one chain covering release, daughter products, dosimetry and patient-safety controls.

Where and when to use it

during therapeutic radiopharmaceutical release, dosimetry planning, free-metal assessment, daughter radionuclide control and handling safety review. Medical use: renal and urinary, hepatobiliary and GI, bone and musculoskeletal, oncology and theranostics. Workflow stages: product release QC, generators and isotope purity, imaging QC and quantitative interpretation.

Input fields

BatchNumber, TotalActivityMBq, RadionuclidicPurityPercent, Europium154ImpurityPercent, Europium155ImpurityPercent, RadiochemicalPurityPercent, FreeSamariumPercent, pH, EndotoxinsEU, SterilityTest

Open utility

Related utilities
Sm-153 EDTMP Bone Pain QC API / calculation and rule-basedSm-153
What it does

Utility checks critical parameters of Sm-153 EDTMP: Radiochemical purity (≥95%) Free samarium (≤5%) Eu-154 impurity (<0.001%) — CRITICAL!

Why it is needed

Supports theranostics and radionuclide therapy as one chain covering release, daughter products, dosimetry and patient-safety controls.

Where and when to use it

during therapeutic radiopharmaceutical release, dosimetry planning, free-metal assessment, daughter radionuclide control and handling safety review. Medical use: hepatobiliary and GI, bone and musculoskeletal, oncology and theranostics. Workflow stages: product release QC, generators and isotope purity, imaging QC and quantitative interpretation.

Input fields

BatchNumber, RadiochemicalPurityPercent, FreeSamariumPercent, pH, SpecificActivityMBq_per_mg, EndotoxinsEU_per_mL, SterilityTest, ActivityMBq, RadionuclidicPurityPercent, Eu154ImpurityPercent

Open utility

Related utilities
Specific Activity Calculator API / calculation and rule-basedAc-225Cu-64Ga-68Lu-177Y-90
What it does

Calculates specific activity (MBq/nmol) with decay correction. Supports F-18, Ga-68, Lu-177, Ac-225, Y-90, Cu-64, etc. SpecificActivityCalculator.exe → demo mode SpecificActivityCalculator.exe input.csv output.json → calculation

Why it is needed

Supports theranostics and radionuclide therapy as one chain covering release, daughter products, dosimetry and patient-safety controls.

Where and when to use it

during therapeutic radiopharmaceutical release, dosimetry planning, free-metal assessment, daughter radionuclide control and handling safety review. Medical use: oncology and theranostics. Workflow stages: synthesis, labelling and kit reconstitution, product release QC, generators and isotope purity.

Input fields

BatchNumber, Radionuclide, Measured_Activity_MBq, Measurement_Time_ISO, Mass_Ligand_ug, Molecular_Weight_g_mol, Reference_Time_ISO, Min_Specific_Activity_MBq_nmol

Open utility

Related utilities
Sr-89 Chloride Palliation QC API / calculation and rule-basedSr-89
What it does

Utility checks critical parameters of Sr-89 Chloride: Radionuclidic purity (≥99.9%) Sr-85 impurity (<0.01%) Chemical purity and aluminum content

Why it is needed

Supports theranostics and radionuclide therapy as one chain covering release, daughter products, dosimetry and patient-safety controls.

Where and when to use it

during therapeutic radiopharmaceutical release, dosimetry planning, free-metal assessment, daughter radionuclide control and handling safety review. Medical use: bone and musculoskeletal, oncology and theranostics. Workflow stages: product release QC, generators and isotope purity, imaging QC and quantitative interpretation.

Input fields

BatchNumber, RadionuclidicPurityPercent, Sr85ImpurityPercent, OtherRadionuclidesPercent, pH, Osmolality_mOsm_per_kg, EndotoxinsEU_per_mL, SterilityTest, ActivityMBq, ChemicalPurityPercent

Open utility

Related utilities
SSTRRadioligand Release Checker API / calculation and rule-basedGeneral RPH
What it does

Utility performs deterministic QC review for radioligand / theranostics products: Source priority: Ph. Eur. → British Pharmacopoeia / UK implementation → EAEU → EMA/ICH/EU guidance → USP fallback Strict API defaults when exact monograph is not yet encoded: Assay 98–102%, Total impurities ≤1.0%, Individual impurity ≤0.5%

Why it is needed

Supports theranostics and radionuclide therapy as one chain covering release, daughter products, dosimetry and patient-safety controls.

Where and when to use it

during therapeutic radiopharmaceutical release, dosimetry planning, free-metal assessment, daughter radionuclide control and handling safety review. Medical use: oncology and theranostics. Workflow stages: product release QC.

Input fields

BatchNumber, ProductName, SubstanceName, ProductClass, Assay_Percent, TotalImpurities_Percent, IndividualImpurityMax_Percent, Aggregates_Percent, Sterility_Result, Endotoxin_Value

Open utility

Related utilities
Strontium89 Chloride Quality Checker API / calculation and rule-basedSr-89
What it does

The utility checks activity, radiochemical purity, strontium-85 impurity, pH, chlorides, endotoxins, sterility, heavy metals, residual solvents. Does not use machine learning — rule-based logic only. Strontium89ChlorideQualityChecker.exe → demo mode (console output) Strontium89ChlorideQualityChecker.exe input.csv output.json → evaluate your data

Why it is needed

Supports theranostics and radionuclide therapy as one chain covering release, daughter products, dosimetry and patient-safety controls.

Where and when to use it

during therapeutic radiopharmaceutical release, dosimetry planning, free-metal assessment, daughter radionuclide control and handling safety review. Medical use: hepatobiliary and GI, bone and musculoskeletal, oncology and theranostics. Workflow stages: product release QC, stability, storage, decay and waste.

Input fields

BatchNumber, ActivityMBqPerMl, RadiochemicalPurityPercent, Strontium85ImpurityPercent, pH, ChloridesMgPerMl, EndotoxinsEU, SterilityTest, HeavyMetalsPPM, EthanolPPM

Open utility

Related utilities
Tb-161 Radioligand Quality Checker API / calculation and rule-basedTb-161
What it does

Utility checks critical parameters of Tb-161 Radioligand: Radiochemical purity (≥95%) Free terbium (≤2%) Tb-160 impurity (<0.01%) — CRITICAL!

Why it is needed

Supports theranostics and radionuclide therapy as one chain covering release, daughter products, dosimetry and patient-safety controls.

Where and when to use it

during therapeutic radiopharmaceutical release, dosimetry planning, free-metal assessment, daughter radionuclide control and handling safety review. Medical use: hepatobiliary and GI, bone and musculoskeletal, oncology and theranostics. Workflow stages: synthesis, labelling and kit reconstitution, product release QC, generators and isotope purity.

Input fields

BatchNumber, RadiochemicalPurityPercent, FreeTerbiumPercent, PrecursorPercent, SpecificActivityGBq_per_mg, pH, ResidualSolventsPPM, EndotoxinsEU_per_mL, SterilityTest, ActivityMBq

Open utility

Related utilities
Tb161 Radionuclidic Purity Checker API / calculation and rule-basedTb-161
What it does

Utility analyzes gamma spectra for impurities: Tb-161 purity (≥99.9%) Tb-160 impurity (≤0.1%) Target (Gd-153) and activation (Eu-152) impurities

Why it is needed

Supports theranostics and radionuclide therapy as one chain covering release, daughter products, dosimetry and patient-safety controls.

Where and when to use it

during therapeutic radiopharmaceutical release, dosimetry planning, free-metal assessment, daughter radionuclide control and handling safety review. Medical use: endocrine, thyroid and NET, oncology and theranostics. Workflow stages: product release QC, generators and isotope purity, imaging QC and quantitative interpretation.

Input fields

BatchNumber, ProductName, Activity_Tb161, Activity_Tb160, Activity_Gd153, Activity_Eu152, Max_Tb160_Percent, Max_Other_Impurities_Percent

Open utility

Related utilities
Tc-99m HMPAO Brain Perfusion Stability Checker API / calculation and rule-basedTc-99m
What it does

Utility checks critical stability parameters of Tc-99m HMPAO: Lipophilic complex fraction (≥80%) Time since preparation (<30 min) Secondary hydrophilic complex (<20%)

Why it is needed

Supports theranostics and radionuclide therapy as one chain covering release, daughter products, dosimetry and patient-safety controls.

Where and when to use it

during therapeutic radiopharmaceutical release, dosimetry planning, free-metal assessment, daughter radionuclide control and handling safety review. Medical use: brain and CNS, endocrine, thyroid and NET, oncology and theranostics. Workflow stages: product release QC, imaging QC and quantitative interpretation, stability, storage, decay and waste.

Input fields

BatchNumber, RadiochemicalPurityPercent, SecondaryComplexPercent, FreeTechnetiumPercent, TimeSincePreparationMin, MaxAllowedTimeMin, pH, ActivityMBq, StorageCondition

Open utility

Related utilities
Terbium-149 Quality Checker API / calculation and rule-basedGeneral RPH
What it does

The utility checks RCP, long-lived impurities (Tb-155/156), free terbium, specific activity. Does not use machine learning — rule-based logic only. Terbium149QualityChecker.exe → demo mode Terbium149QualityChecker.exe input.csv output.json → evaluate data

Why it is needed

Supports theranostics and radionuclide therapy as one chain covering release, daughter products, dosimetry and patient-safety controls.

Where and when to use it

during therapeutic radiopharmaceutical release, dosimetry planning, free-metal assessment, daughter radionuclide control and handling safety review. Medical use: hepatobiliary and GI, endocrine, thyroid and NET, bone and musculoskeletal, oncology and theranostics. Workflow stages: synthesis, labelling and kit reconstitution, product release QC, generators and isotope purity.

Input fields

BatchNumber, Radiopharmaceutical, Radionuclidic_Purity_Percent, Radiochemical_Purity_Percent, Specific_Activity_MBq_nmol, Long_Lived_Tb_Impurities_Percent, Free_Terbium_Ion_Percent, Target_Material_Residue_ppm, pH_Value, Ethanol_Content_Percent

Open utility

Related utilities
Terbium-155 Quality Checker API / calculation and rule-basedGeneral RPH
What it does

The utility checks RCP, other Tb isotopes, free terbium, specific activity. Does not use machine learning — rule-based logic only. Terbium155QualityChecker.exe → demo mode Terbium155QualityChecker.exe input.csv output.json → evaluate data

Why it is needed

Supports theranostics and radionuclide therapy as one chain covering release, daughter products, dosimetry and patient-safety controls.

Where and when to use it

during therapeutic radiopharmaceutical release, dosimetry planning, free-metal assessment, daughter radionuclide control and handling safety review. Medical use: hepatobiliary and GI, endocrine, thyroid and NET, bone and musculoskeletal, oncology and theranostics. Workflow stages: product release QC, generators and isotope purity.

Input fields

BatchNumber, Radiopharmaceutical, Radionuclidic_Purity_Percent, Radiochemical_Purity_Percent, Specific_Activity_MBq_nmol, Other_Tb_Isotopes_Percent, Free_Terbium_Ion_Percent, Target_Material_Residue_ppm, pH_Value, Ethanol_Content_Percent

Open utility

Related utilities
Terbium-161 Quality Checker API / calculation and rule-basedTb-161
What it does

Utility checks critical parameters of terbium-161: Radionuclidic purity (≥99.9%) Terbium-160 impurity (≤0.1%) — CRITICAL! Radiochemical purity (≥95%)

Why it is needed

Supports theranostics and radionuclide therapy as one chain covering release, daughter products, dosimetry and patient-safety controls.

Where and when to use it

during therapeutic radiopharmaceutical release, dosimetry planning, free-metal assessment, daughter radionuclide control and handling safety review. Medical use: hepatobiliary and GI, brain and CNS, endocrine, thyroid and NET, bone and musculoskeletal, oncology and theranostics. Workflow stages: synthesis, labelling and kit reconstitution, product release QC, generators and isotope purity.

Input fields

BatchNumber, ActivityMBq, RadionuclidicPurityPercent, Tb160ImpurityPercent, RadiochemicalPurityPercent, GadoliniumContentPPM, pH, EndotoxinsEU, SterilityTest, ProductType

Open utility

Related utilities
Terbium161 Radioligand Checker API / calculation and rule-basedTb-161
What it does

Utility performs deterministic QC review for radioligand / theranostics products: Source priority: Ph. Eur. → British Pharmacopoeia / UK implementation → EAEU → EMA/ICH/EU guidance → USP fallback Strict API defaults when exact monograph is not yet encoded: Assay 98–102%, Total impurities ≤1.0%, Individual impurity ≤0.5%

Why it is needed

Supports theranostics and radionuclide therapy as one chain covering release, daughter products, dosimetry and patient-safety controls.

Where and when to use it

during therapeutic radiopharmaceutical release, dosimetry planning, free-metal assessment, daughter radionuclide control and handling safety review. Medical use: oncology and theranostics. Workflow stages: product release QC.

Input fields

BatchNumber, ProductName, SubstanceName, ProductClass, Assay_Percent, TotalImpurities_Percent, IndividualImpurityMax_Percent, Aggregates_Percent, Sterility_Result, Endotoxin_Value

Open utility

Related utilities
Theranostic Paired Dose Calculator API / calculation and rule-basedGeneral RPH
What it does

Utility calculates personalized therapeutic dose: Based on diagnostic PET/CT data Considering critical organ dose limits (kidneys) Considering target tumor dose

Why it is needed

Supports theranostics and radionuclide therapy as one chain covering release, daughter products, dosimetry and patient-safety controls.

Where and when to use it

during therapeutic radiopharmaceutical release, dosimetry planning, free-metal assessment, daughter radionuclide control and handling safety review. Medical use: renal and urinary, oncology and theranostics. Workflow stages: dosimetry and therapy planning, imaging QC and quantitative interpretation, stability, storage, decay and waste.

Input fields

BatchNumber, PatientID, RadioligandPair, Diag_Activity_MBq, Diag_HalfLife_h, Tumor_Uptake_SUV, Kidney_Uptake_SUV, Ther_HalfLife_h, Max_Tolerated_Dose_Gy, Target_Tumor_Dose_Gy

Open utility

Related utilities
Thorium-227 Quality Checker API / calculation and rule-basedTh-227
What it does

The utility checks RCP, free thorium, daughter nuclides, long-lived impurities, sterility. Does not use machine learning — rule-based logic only. Thorium227QualityChecker.exe → demo mode Thorium227QualityChecker.exe input.csv output.json → evaluate data

Why it is needed

Supports theranostics and radionuclide therapy as one chain covering release, daughter products, dosimetry and patient-safety controls.

Where and when to use it

during therapeutic radiopharmaceutical release, dosimetry planning, free-metal assessment, daughter radionuclide control and handling safety review. Medical use: hepatobiliary and GI, bone and musculoskeletal, oncology and theranostics. Workflow stages: synthesis, labelling and kit reconstitution, product release QC, generators and isotope purity.

Input fields

BatchNumber, Radiopharmaceutical, Radionuclidic_Purity_Percent, Radiochemical_Purity_Percent, Specific_Activity_MBq_mg_Ab, Long_Lived_Th_Impurities_Percent, Free_Thorium_Ion_Percent, Daughter_Nuclide_Escape_Percent, pH_Value, Protein_Concentration_mg_per_mL

Open utility

Related utilities
Y-90 Microsphere Radioembolization Checker API / calculation and rule-basedY-90
What it does

Utility checks critical parameters of Y-90 microspheres: Particle size (10-60 μm) and D90 (<70 μm) Radiochemical purity (≥99%) Free yttrium (<0.1%)

Why it is needed

Supports theranostics and radionuclide therapy as one chain covering release, daughter products, dosimetry and patient-safety controls.

Where and when to use it

during therapeutic radiopharmaceutical release, dosimetry planning, free-metal assessment, daughter radionuclide control and handling safety review. Medical use: pulmonary and ventilation, hepatobiliary and GI, bone and musculoskeletal, oncology and theranostics. Workflow stages: product release QC, dosimetry and therapy planning.

Input fields

BatchNumber, MicrosphereType, MeanParticleSizeUm, ParticleSizeD90Um, PolydispersityIndex, RadiochemicalPurityPercent, FreeYttriumPercent, ActivityGBq, SpecificActivityGBq_per_g, pH

Open utility

Related utilities
Yttrium86 Quality Checker API / calculation and rule-basedY-86Y-90
What it does

Utility checks critical parameters of Yttrium-86: Radionuclidic purity (≥99.0%) Yttrium-87 impurity (≤1.0%) Yttrium-88 impurity (≤0.01%) — CRITICAL!

Why it is needed

Supports theranostics and radionuclide therapy as one chain covering release, daughter products, dosimetry and patient-safety controls.

Where and when to use it

during therapeutic radiopharmaceutical release, dosimetry planning, free-metal assessment, daughter radionuclide control and handling safety review. Medical use: hepatobiliary and GI, bone and musculoskeletal, oncology and theranostics. Workflow stages: synthesis, labelling and kit reconstitution, product release QC, generators and isotope purity.

Input fields

BatchNumber, TotalActivityMBq, RadionuclidicPurityPercent, Yttrium87ImpurityPercent, Yttrium88ImpurityPercent, Strontium82ImpurityPercent, RadiochemicalPurityPercent, FreeYttriumPercent, pH, EndotoxinsEU

Open utility

Related utilities
Yttrium90 Glass Microsphere Checker API / calculation and rule-basedY-90
What it does

Utility checks critical parameters of Y-90 Glass Microspheres: Particle size (20–30 μm) — strict! Sphericity (≥95%) Activity per sphere (~2500 Bq)

Why it is needed

Supports theranostics and radionuclide therapy as one chain covering release, daughter products, dosimetry and patient-safety controls.

Where and when to use it

during therapeutic radiopharmaceutical release, dosimetry planning, free-metal assessment, daughter radionuclide control and handling safety review. Medical use: pulmonary and ventilation, hepatobiliary and GI, bone and musculoskeletal, oncology and theranostics. Workflow stages: product release QC, generators and isotope purity, dosimetry and therapy planning.

Input fields

BatchNumber, TotalActivityGBq, ActivityPerSphereBq, MeanDiameterMicrons, DiameterRangeMinMicrons, DiameterRangeMaxMicrons, SphericityPercent, RadionuclidicPurityPercent, Yttrium88ImpurityPercent, FreeYttriumPercent

Open utility

Related utilities
Yttrium90 Quality Checker API / calculation and rule-basedY-90
What it does

Utility checks critical parameters of yttrium-90: Specific activity (≥1000 MBq/μmol for conjugates) Radiochemical purity (≥95%) Yttrium-88 impurity (≤0.001%) — CRITICAL!

Why it is needed

Supports theranostics and radionuclide therapy as one chain covering release, daughter products, dosimetry and patient-safety controls.

Where and when to use it

during therapeutic radiopharmaceutical release, dosimetry planning, free-metal assessment, daughter radionuclide control and handling safety review. Medical use: pulmonary and ventilation, hepatobiliary and GI, brain and CNS, endocrine, thyroid and NET, oncology and theranostics. Workflow stages: synthesis, labelling and kit reconstitution, product release QC, stability, storage, decay and waste.

Input fields

BatchNumber, SpecificActivityMBqPerUmol, RadiochemicalPurityPercent, Yttrium88ImpurityPercent, FreeYttriumPercent, pH, EndotoxinsEU, SterilityTest, HeavyMetalsPPM, ProductType

Open utility

Related utilities
Yttrium90 Resin Microsphere Checker API / calculation and rule-basedY-90
What it does

Utility checks critical parameters of Y-90 Resin Microspheres: Particle size (20–60 μm) Number of particles (important for dosimetry) Sphericity (≥90%)

Why it is needed

Supports theranostics and radionuclide therapy as one chain covering release, daughter products, dosimetry and patient-safety controls.

Where and when to use it

during therapeutic radiopharmaceutical release, dosimetry planning, free-metal assessment, daughter radionuclide control and handling safety review. Medical use: pulmonary and ventilation, hepatobiliary and GI, bone and musculoskeletal, oncology and theranostics. Workflow stages: synthesis, labelling and kit reconstitution, product release QC, generators and isotope purity.

Input fields

BatchNumber, TotalActivityGBq, NumberOfParticlesMillions, MeanDiameterMicrons, DiameterRangeMinMicrons, DiameterRangeMaxMicrons, SphericityPercent, RadionuclidicPurityPercent, Yttrium88ImpurityPercent, FreeYttriumPercent

Open utility

Related utilities
Zirconium89 DFO Quality Checker API / calculation and rule-basedY-90Zr-89
What it does

Utility checks critical parameters of Zr-89-DFO: Radionuclidic purity (≥99.0%) Yttrium-88 impurity (≤0.001%) — CRITICAL! Yttrium-87 impurity (≤0.1%)

Why it is needed

Supports theranostics and radionuclide therapy as one chain covering release, daughter products, dosimetry and patient-safety controls.

Where and when to use it

during therapeutic radiopharmaceutical release, dosimetry planning, free-metal assessment, daughter radionuclide control and handling safety review. Medical use: bone and musculoskeletal, oncology and theranostics. Workflow stages: synthesis, labelling and kit reconstitution, product release QC, generators and isotope purity.

Input fields

BatchNumber, TotalActivityMBq, RadionuclidicPurityPercent, Yttrium88ImpurityPercent, Yttrium87ImpurityPercent, RadiochemicalPurityPercent, FreeZirconiumPercent, pH, EndotoxinsEU, SterilityTest

Open utility

Related utilities
Zirconium89 Trastuzumab Quality Checker API / calculation and rule-basedY-90Zr-89
What it does

Utility checks critical parameters of Zr-89-Trastuzumab: Immunoreactivity (≥80%) — MAIN PARAMETER! Absence of aggregates (≤5%) Radiochemical purity (≥95%)

Why it is needed

Supports theranostics and radionuclide therapy as one chain covering release, daughter products, dosimetry and patient-safety controls.

Where and when to use it

during therapeutic radiopharmaceutical release, dosimetry planning, free-metal assessment, daughter radionuclide control and handling safety review. Medical use: hepatobiliary and GI, bone and musculoskeletal, oncology and theranostics. Workflow stages: synthesis, labelling and kit reconstitution, product release QC, generators and isotope purity.

Input fields

BatchNumber, TotalActivityMBq, ProteinConcentrationMgPerMl, SpecificActivityGBqPerUmol, RadionuclidicPurityPercent, Yttrium88ImpurityPercent, RadiochemicalPurityPercent, FreeZirconiumPercent, ImmunoreactivityPercent, AggregatesPercent

Open utility

Related utilities
Zr-89 Monoclonal Antibody Labeling QC API / calculation and rule-basedZr-89
What it does

Utility checks critical parameters of Zr-89 mAbs: Radiochemical purity (≥95%) Free zirconium (≤2%) Immunoreactivity (≥90%)

Why it is needed

Supports theranostics and radionuclide therapy as one chain covering release, daughter products, dosimetry and patient-safety controls.

Where and when to use it

during therapeutic radiopharmaceutical release, dosimetry planning, free-metal assessment, daughter radionuclide control and handling safety review. Medical use: hepatobiliary and GI, bone and musculoskeletal, oncology and theranostics. Workflow stages: synthesis, labelling and kit reconstitution, product release QC, generators and isotope purity.

Input fields

BatchNumber, AntibodyName, RadiochemicalPurityPercent, FreeZirconiumPercent, AggregatesPercent, SpecificActivityMBq_per_mg, ImmunoreactivityPercent, pH, EndotoxinsEU_per_mL, SterilityTest

Open utility

Related utilities
generators, isotope purity and starting radionuclides 39

Control of generator eluate, breakthrough, radionuclidic purity, isotope mix, carrier/free radionuclides and starting radionuclides before labeling.

Open package

API / calculation and rule-based 39

Cobalt57 Quality Checker API / calculation and rule-basedTc-99m
What it does

Utility checks critical parameters of cobalt-57: Radionuclidic purity (≥99.9%) Cobalt-56 impurity (≤0.05%) — long-lived impurity (T½=77 days) Cobalt-58 impurity (≤0.05%) — (T½=71 days)

Why it is needed

Supports control of the starting radionuclide, generator eluate, breakthrough and radionuclidic purity before final radiopharmaceutical release.

Where and when to use it

during generator acceptance, elution control, incoming radionuclide QC and investigation of unexpected peaks or impurities. Workflow stages: product release QC, generators and isotope purity, stability, storage, decay and waste.

Input fields

BatchNumber, RadionuclidicPurityPercent, Co56ImpurityPercent, Co58ImpurityPercent, ChemicalPurityPercent, pH, EndotoxinsEU, SterilityTest, HeavyMetalsPPM, ProductType

Open utility

Related utilities
Cobalt58 Quality Checker API / calculation and rule-basedGeneral RPH
What it does

Limited source description was provided. The utility shall read input.csv, validate declared fields, apply deterministic acceptance rules defined in the executable and produce output.json for QA/QC review.

Why it is needed

Supports control of the starting radionuclide, generator eluate, breakthrough and radionuclidic purity before final radiopharmaceutical release.

Where and when to use it

during generator acceptance, elution control, incoming radionuclide QC and investigation of unexpected peaks or impurities. Workflow stages: product release QC, generators and isotope purity.

Input fields

id, val

Open utility

Related utilities
Copper67 Quality Checker API / calculation and rule-basedCu-67
What it does

Utility checks critical parameters of copper-67: Specific activity (≥100 MBq/μmol for conjugates) Radiochemical purity (≥95%) Copper-64 impurity (≤0.1%) — CRITICAL!

Why it is needed

Supports control of the starting radionuclide, generator eluate, breakthrough and radionuclidic purity before final radiopharmaceutical release.

Where and when to use it

during generator acceptance, elution control, incoming radionuclide QC and investigation of unexpected peaks or impurities. Medical use: renal and urinary, hepatobiliary and GI, brain and CNS, endocrine, thyroid and NET, oncology and theranostics. Workflow stages: synthesis, labelling and kit reconstitution, product release QC, generators and isotope purity.

Input fields

BatchNumber, SpecificActivityMBqPerUmol, RadiochemicalPurityPercent, Copper64ImpurityPercent, FreeCopperPercent, pH, EndotoxinsEU, SterilityTest, HeavyMetalsPPM, ProductType

Open utility

Related utilities
Daughter Nuclide Ingrowth Calculator API / calculation and rule-basedGa-68Ge-68Rb-82Sr-82Tc-99m
What it does

Utility calculates theoretical activity of daughter isotopes in radiopharmaceutical generators: Supported pairs: Mo-99/Tc-99m, Sr-82/Rb-82, Ge-68/Ga-68, Ti-44/Sc-44, Zn-62/Cu-62 Calculation using Bateman equations Determination of radioactive equilibrium type

Why it is needed

Supports control of the starting radionuclide, generator eluate, breakthrough and radionuclidic purity before final radiopharmaceutical release.

Where and when to use it

during generator acceptance, elution control, incoming radionuclide QC and investigation of unexpected peaks or impurities. Medical use: hepatobiliary and GI. Workflow stages: product release QC, generators and isotope purity, stability, storage, decay and waste.

Input fields

BatchNumber, ParentIsotope, InitialParentActivityMBq, ElapsedTimeHours, DaughterHalfLifeHours, ParentHalfLifeHours

Open utility

Related utilities
Decay Corrector API / calculation and rule-basedGeneral RPH
What it does

The utility calculates decay-corrected radionuclide activity from calibration time to measurement or administration time. Does not use machine learning — physics-based formulas and rules only. DecayCorrector.exe → demo mode (console output) DecayCorrector.exe input.csv output.json → calculation on your data

Why it is needed

Supports control of the starting radionuclide, generator eluate, breakthrough and radionuclidic purity before final radiopharmaceutical release.

Where and when to use it

during generator acceptance, elution control, incoming radionuclide QC and investigation of unexpected peaks or impurities. Workflow stages: product release QC, generators and isotope purity, stability, storage, decay and waste.

Input fields

BatchNumber, Radionuclide, MeasuredActivityMBq, CalibrationTime, MeasurementTime

Open utility

Related utilities
Dosimetry Pre-Calculator API / calculation and rule-basedAc-225Cu-64Ga-68I-131Lu-177Tc-99mZr-89
What it does

Calculates activity at injection time, effective dose, and critical organ load. Supports F-18, Ga-68, Tc-99m, Lu-177, Ac-225, Cu-64, I-131, Zr-89. DosimetryPreCalculator.exe → demo mode DosimetryPreCalculator.exe input.csv output.json → calculation

Why it is needed

Supports control of the starting radionuclide, generator eluate, breakthrough and radionuclidic purity before final radiopharmaceutical release.

Where and when to use it

during generator acceptance, elution control, incoming radionuclide QC and investigation of unexpected peaks or impurities. Medical use: renal and urinary, bone and musculoskeletal. Workflow stages: product release QC, generators and isotope purity, dosimetry and therapy planning.

Input fields

PatientID, Radiopharmaceutical, Radionuclide, Reference_Activity_MBq, Calibration_Time_ISO, Injection_Time_ISO, Patient_Weight_kg, Patient_Age_years, Min_Dose_MBq, Max_Dose_MBq

Open utility

Related utilities
Erbium-169 Quality Checker API / calculation and rule-basedGeneral RPH
What it does

The utility checks particle size, RCP, free ions, sterility, endotoxins. Does not use machine learning — rule-based logic only. Erbium169QualityChecker.exe → demo mode Erbium169QualityChecker.exe input.csv output.json → evaluate data

Why it is needed

Supports control of the starting radionuclide, generator eluate, breakthrough and radionuclidic purity before final radiopharmaceutical release.

Where and when to use it

during generator acceptance, elution control, incoming radionuclide QC and investigation of unexpected peaks or impurities. Medical use: hepatobiliary and GI, bone and musculoskeletal, lymphatic, infection and inflammation. Workflow stages: product release QC, generators and isotope purity, stability, storage, decay and waste.

Input fields

BatchNumber, Radionuclidic_Purity_Percent, Radiochemical_Purity_Percent, Specific_Activity_MBq_mg, Particle_Size_Mean_nm, Particle_Size_Max_nm, Aggregation_Percent, Free_Erbium_Ion_Percent, Target_Material_Residue_ppm, pH_Value

Open utility

Related utilities
Generator Elution Predictor API / calculation and rule-basedGeneral RPH
What it does

Utility calculates PREDICTED daughter nuclide activity in generator eluate: Accounts for parent nuclide decay since calibration Accounts for daughter nuclide ingrowth between elutions Applies elution efficiency to calculate activity in eluate

Why it is needed

Supports control of the starting radionuclide, generator eluate, breakthrough and radionuclidic purity before final radiopharmaceutical release.

Where and when to use it

during generator acceptance, elution control, incoming radionuclide QC and investigation of unexpected peaks or impurities. Medical use: renal and urinary, cardiovascular, bone and musculoskeletal, oncology and theranostics. Workflow stages: product release QC, generators and isotope purity, imaging QC and quantitative interpretation.

Input fields

BatchNumber, GeneratorType, GeneratorCalibrationActivityMBq, CalibrationDateTime, LastElutionDateTime, NextElutionDateTime, ElutionEfficiencyPercent, DosePerPatientMBq

Open utility

Related utilities
Indium111 Capromab Pendetide Checker API / calculation and rule-basedIn-111
What it does

Utility checks critical parameters of the monoclonal antibody-based radiopharmaceutical: Radiochemical purity (≥90%) Free Indium-111 impurity (≤5%) Colloidal Indium-111 impurity (≤5%)

Why it is needed

Supports control of the starting radionuclide, generator eluate, breakthrough and radionuclidic purity before final radiopharmaceutical release.

Where and when to use it

during generator acceptance, elution control, incoming radionuclide QC and investigation of unexpected peaks or impurities. Medical use: hepatobiliary and GI, bone and musculoskeletal, oncology and theranostics. Workflow stages: synthesis, labelling and kit reconstitution, product release QC, generators and isotope purity.

Input fields

BatchNumber, RadiochemicalPurityPercent, FreeIndium111Percent, ColloidalIndium111Percent, SpecificActivityMBqPerMg, pH, EndotoxinsEU, SterilityTest, HeavyMetalsPPM, ProteinConcentrationMgPerMl

Open utility

Related utilities
Iodine123 FPCT Quality Checker API / calculation and rule-basedI-123
What it does

Utility checks critical parameters of the radiopharmaceutical for dopamine transporter imaging: Radiochemical purity (≥95%) Free Iodine-123 impurity (≤5%) Radionuclidic impurity Iodine-124 (≤0.3%) — CRITICAL!

Why it is needed

Supports control of the starting radionuclide, generator eluate, breakthrough and radionuclidic purity before final radiopharmaceutical release.

Where and when to use it

during generator acceptance, elution control, incoming radionuclide QC and investigation of unexpected peaks or impurities. Medical use: brain and CNS, endocrine, thyroid and NET. Workflow stages: product release QC, generators and isotope purity, imaging QC and quantitative interpretation.

Input fields

BatchNumber, RadiochemicalPurityPercent, FreeIodine123Percent, RadionuclidicPurityI124Percent, RadionuclidicPurityI125Percent, SpecificActivityGBqPerUmol, pH, EndotoxinsEU, SterilityTest, EthanolPercent

Open utility

Related utilities
Iodine123 Ioflupane Quality Checker API / calculation and rule-basedI-123
What it does

Utility checks critical parameters of the radiopharmaceutical for dopamine transporter imaging: Radiochemical purity (≥95%) Free Iodine-123 impurity (≤5%) Radionuclidic impurity Iodine-124 (≤0.3%) — CRITICAL!

Why it is needed

Supports control of the starting radionuclide, generator eluate, breakthrough and radionuclidic purity before final radiopharmaceutical release.

Where and when to use it

during generator acceptance, elution control, incoming radionuclide QC and investigation of unexpected peaks or impurities. Medical use: brain and CNS, endocrine, thyroid and NET. Workflow stages: product release QC, generators and isotope purity, imaging QC and quantitative interpretation.

Input fields

BatchNumber, RadiochemicalPurityPercent, FreeIodine123Percent, RadionuclidicPurityI124Percent, RadionuclidicPurityI125Percent, SpecificActivityGBqPerUmol, pH, EndotoxinsEU, SterilityTest, EthanolPercent

Open utility

Related utilities
Iodine123 MIBG Quality Checker API / calculation and rule-basedI-123
What it does

Utility checks critical parameters of Iodine-123 MIBG radiopharmaceutical: Radiochemical purity (≥95%) Free Iodine-123 impurity (≤5%) Radionuclidic impurity Iodine-124 (≤0.5%)

Why it is needed

Supports control of the starting radionuclide, generator eluate, breakthrough and radionuclidic purity before final radiopharmaceutical release.

Where and when to use it

during generator acceptance, elution control, incoming radionuclide QC and investigation of unexpected peaks or impurities. Medical use: cardiovascular, brain and CNS, endocrine, thyroid and NET, oncology and theranostics. Workflow stages: synthesis, labelling and kit reconstitution, product release QC, generators and isotope purity.

Input fields

BatchNumber, RadiochemicalPurityPercent, FreeIodine123Percent, RadionuclidicPurityI124Percent, RadionuclidicPurityI125Percent, SpecificActivityMBqPerUg, pH, EndotoxinsEU, SterilityTest, AppearanceScore

Open utility

Related utilities
Iodine123 Na I Quality Checker API / calculation and rule-basedI-123I-124
What it does

Utility checks critical parameters of Sodium Iodide I-123: Radionuclidic purity (≥99% I-123) Iodine-124 impurity (≤0.5%) — CRITICAL! Iodine-125 impurity (≤0.5%)

Why it is needed

Supports control of the starting radionuclide, generator eluate, breakthrough and radionuclidic purity before final radiopharmaceutical release.

Where and when to use it

during generator acceptance, elution control, incoming radionuclide QC and investigation of unexpected peaks or impurities. Medical use: endocrine, thyroid and NET. Workflow stages: synthesis, labelling and kit reconstitution, product release QC, generators and isotope purity.

Input fields

BatchNumber, RadionuclidicPurityI123Percent, RadionuclidicImpurityI124Percent, RadionuclidicImpurityI125Percent, RadiochemicalPurityPercent, pH, EndotoxinsEU, SterilityTest, TotalActivityMBq, AppearanceScore

Open utility

Related utilities
Iodine124 MAB Quality Checker API / calculation and rule-basedI-123I-124I-125
What it does

Utility checks critical parameters of Iodine-124 labeled monoclonal antibodies: Radiochemical purity (≥90%) Free Iodine-124 impurity (≤5%) Immunoreactive fraction (≥70%) — CRITICAL!

Why it is needed

Supports control of the starting radionuclide, generator eluate, breakthrough and radionuclidic purity before final radiopharmaceutical release.

Where and when to use it

during generator acceptance, elution control, incoming radionuclide QC and investigation of unexpected peaks or impurities. Medical use: hepatobiliary and GI, endocrine, thyroid and NET, oncology and theranostics. Workflow stages: synthesis, labelling and kit reconstitution, product release QC, generators and isotope purity.

Input fields

BatchNumber, RadiochemicalPurityPercent, FreeIodine124Percent, RadionuclidicPurityI123Percent, RadionuclidicPurityI125Percent, SpecificActivityMBqPerMg, ImmunoreactiveFractionPercent, AggregatePercent, pH, EndotoxinsEU

Open utility

Related utilities
Manganese52 Quality Checker API / calculation and rule-basedGeneral RPH
What it does

Utility checks critical parameters of Manganese-52: Radionuclidic purity (≥99.0%) Manganese-54 impurity (≤0.1%) Manganese-56 impurity (≤1.0%)

Why it is needed

Supports control of the starting radionuclide, generator eluate, breakthrough and radionuclidic purity before final radiopharmaceutical release.

Where and when to use it

during generator acceptance, elution control, incoming radionuclide QC and investigation of unexpected peaks or impurities. Medical use: hepatobiliary and GI. Workflow stages: synthesis, labelling and kit reconstitution, product release QC, generators and isotope purity.

Input fields

BatchNumber, TotalActivityMBq, RadionuclidicPurityPercent, Manganese54ImpurityPercent, Manganese56ImpurityPercent, RadiochemicalPurityPercent, FreeManganesePercent, pH, EndotoxinsEU, SterilityTest

Open utility

Related utilities
Mercury197 Quality Checker API / calculation and rule-basedGeneral RPH
What it does

Utility checks critical parameters of Mercury-197: Radionuclidic purity (≥99.0%) Mercury-197m impurity (≤1.0%) Mercury-203 impurity (≤0.1%)

Why it is needed

Supports control of the starting radionuclide, generator eluate, breakthrough and radionuclidic purity before final radiopharmaceutical release.

Where and when to use it

during generator acceptance, elution control, incoming radionuclide QC and investigation of unexpected peaks or impurities. Medical use: renal and urinary, hepatobiliary and GI. Workflow stages: product release QC, generators and isotope purity, imaging QC and quantitative interpretation.

Input fields

BatchNumber, TotalActivityMBq, RadionuclidicPurityPercent, Mercury197mImpurityPercent, Mercury203ImpurityPercent, RadiochemicalPurityPercent, FreeMercuryPercent, pH, EndotoxinsEU, SterilityTest

Open utility

Related utilities
Palladium103 Quality Checker API / calculation and rule-basedGeneral RPH
What it does

Utility checks critical parameters of Palladium-103: Radionuclidic purity (≥99.9%) Palladium-109 impurity (≤0.1%) Chemical purity (≥99.0%)

Why it is needed

Supports control of the starting radionuclide, generator eluate, breakthrough and radionuclidic purity before final radiopharmaceutical release.

Where and when to use it

during generator acceptance, elution control, incoming radionuclide QC and investigation of unexpected peaks or impurities. Medical use: lymphatic, infection and inflammation, oncology and theranostics. Workflow stages: product release QC, generators and isotope purity, instruments, devices and radiation safety.

Input fields

BatchNumber, TotalActivityMBq, RadionuclidicPurityPercent, Palladium109ImpurityPercent, Silver103ImpurityPercent, RadiochemicalPurityPercent, ChemicalPurityPercent, pH, EndotoxinsEU, SterilityTest

Open utility

Related utilities
Phosphorus32 Chromic Phosphate Checker API / calculation and rule-basedP-32
What it does

Utility checks critical parameters of colloidal Phosphorus-32: Radionuclidic purity (≥99.9%) Phosphorus-33 impurity (≤0.1%) Particle size (0.5–10.0 μm) — CRITICAL!

Why it is needed

Supports control of the starting radionuclide, generator eluate, breakthrough and radionuclidic purity before final radiopharmaceutical release.

Where and when to use it

during generator acceptance, elution control, incoming radionuclide QC and investigation of unexpected peaks or impurities. Medical use: bone and musculoskeletal, lymphatic, infection and inflammation. Workflow stages: product release QC, generators and isotope purity, stability, storage, decay and waste.

Input fields

BatchNumber, TotalActivityMBq, RadionuclidicPurityPercent, Phosphorus33ImpurityPercent, ParticleSizeMicrons, ColloidalStabilityPercent, pH, EndotoxinsEU, SterilityTest, FreePhosphatePercent

Open utility

Related utilities
Phosphorus32 Orthophosphate Checker API / calculation and rule-basedP-32
What it does

Utility checks critical parameters of Phosphorus-32 solution: Radionuclidic purity (≥99.9%) Phosphorus-33 impurity (≤0.1%) Radiochemical purity (≥95%, orthophosphate form)

Why it is needed

Supports control of the starting radionuclide, generator eluate, breakthrough and radionuclidic purity before final radiopharmaceutical release.

Where and when to use it

during generator acceptance, elution control, incoming radionuclide QC and investigation of unexpected peaks or impurities. Medical use: hepatobiliary and GI, bone and musculoskeletal, oncology and theranostics. Workflow stages: product release QC, generators and isotope purity, imaging QC and quantitative interpretation.

Input fields

BatchNumber, TotalActivityMBq, RadionuclidicPurityPercent, Phosphorus33ImpurityPercent, RadiochemicalPurityPercent, pH, EndotoxinsEU, SterilityTest, OsmolalityMOsmKg, ProductType

Open utility

Related utilities
Platinum195m Quality Checker API / calculation and rule-basedGeneral RPH
What it does

Utility checks critical parameters of Platinum-195m: Radionuclidic purity (≥99.0%) Pt-191 and Pt-193m impurities (≤0.5% each) Radiochemical purity (≥95%)

Why it is needed

Supports control of the starting radionuclide, generator eluate, breakthrough and radionuclidic purity before final radiopharmaceutical release.

Where and when to use it

during generator acceptance, elution control, incoming radionuclide QC and investigation of unexpected peaks or impurities. Medical use: renal and urinary, oncology and theranostics. Workflow stages: product release QC, generators and isotope purity, dosimetry and therapy planning.

Input fields

BatchNumber, TotalActivityMBq, RadionuclidicPurityPercent, Platinum191ImpurityPercent, Platinum193mImpurityPercent, RadiochemicalPurityPercent, FreePlatinumPercent, pH, EndotoxinsEU, SterilityTest

Open utility

Related utilities
Radiation Dose Calculator API / calculation and rule-basedGeneral RPH
What it does

Utility calculates ESTIMATED absorbed dose based on ICRP data (ICRP 106, 128): Effective dose (mSv) for overall radiation burden assessment Target organ and critical organ doses (mGy) Patient weight correction

Why it is needed

Supports control of the starting radionuclide, generator eluate, breakthrough and radionuclidic purity before final radiopharmaceutical release.

Where and when to use it

during generator acceptance, elution control, incoming radionuclide QC and investigation of unexpected peaks or impurities. Medical use: renal and urinary, hepatobiliary and GI, endocrine, thyroid and NET, bone and musculoskeletal, oncology and theranostics. Workflow stages: product release QC, generators and isotope purity, dosimetry and therapy planning.

Input fields

PatientID, Nuclide, AdministeredActivityMBq, PatientWeightKg, TargetOrgan, PatientSex

Open utility

Related utilities
Radiochemical Purity Checker API / calculation and rule-basedGeneral RPH
What it does

Utility calculates radiochemical purity as (target peak area / total peak area) × 100% from chromatographic analysis data. Supports both methods: TLC (Thin Layer Chromatography) and HPLC (High Performance Liquid Chromatography). Does not use machine learning — only mathematical calculation and interpretation based on pharmaceutical standards.

Why it is needed

Supports control of the starting radionuclide, generator eluate, breakthrough and radionuclidic purity before final radiopharmaceutical release.

Where and when to use it

during generator acceptance, elution control, incoming radionuclide QC and investigation of unexpected peaks or impurities. Medical use: endocrine, thyroid and NET, oncology and theranostics. Workflow stages: product release QC, generators and isotope purity, stability, storage, decay and waste.

Input fields

BatchNumber, AnalysisType, TargetPeakArea, TotalPeakArea, RfValue

Open utility

Related utilities
Radiolabeled Nanoparticle Quality Checker API / calculation and rule-basedGeneral RPH
What it does

Utility checks quality of radiolabeled nanoparticles (liposomes, LNPs, polymer NPs) for research use: Radionuclide quality: specific activity, radiochemical purity, free radionuclide, parent impurity Nanoparticle characteristics: particle size, polydispersity index (PDI), zeta potential Safety parameters: pH, endotoxins, sterility, heavy metals

Why it is needed

Supports control of the starting radionuclide, generator eluate, breakthrough and radionuclidic purity before final radiopharmaceutical release.

Where and when to use it

during generator acceptance, elution control, incoming radionuclide QC and investigation of unexpected peaks or impurities. Medical use: pulmonary and ventilation, hepatobiliary and GI, oncology and theranostics. Workflow stages: product release QC, generators and isotope purity, imaging QC and quantitative interpretation.

Input fields

BatchNumber, Radionuclide, NanoparticleType, TargetOrgan, SpecificActivityMBqPerUmol, RadiochemicalPurityPercent, FreeRadionuclidePercent, ParentNuclideImpurityPercent, ParticleSizeNm, PolydispersityIndex

Open utility

Related utilities
Radionuclide Impurity Checker API / calculation and rule-basedGeneral RPH
What it does

Utility automatically calculates radionuclide impurity percentage with half-life correction. Activity is decay-corrected to reference time (calibration/production time). Supports any radionuclide combinations — just specify half-lives. Does not use machine learning — only physics calculations using formula: A_ref = A_meas × exp(λ × t)

Why it is needed

Supports control of the starting radionuclide, generator eluate, breakthrough and radionuclidic purity before final radiopharmaceutical release.

Where and when to use it

during generator acceptance, elution control, incoming radionuclide QC and investigation of unexpected peaks or impurities. Workflow stages: product release QC, generators and isotope purity, stability, storage, decay and waste.

Input fields

BatchNumber, MainRadionuclide, MainActivityMeasMBq, ImpurityRadionuclide, ImpurityActivityMeasMBq, TimeDiffHours, MainHalfLifeHours, ImpurityHalfLifeHours

Open utility

Related utilities
Radionuclide Mix Checker API / calculation and rule-basedGeneral RPH
What it does

Utility performs CRITICAL data verification to prevent catastrophic errors: Batch number verification (entered vs expected) Radionuclide verification (entered vs expected) Activity deviation check from expected value (±20%)

Why it is needed

Supports control of the starting radionuclide, generator eluate, breakthrough and radionuclidic purity before final radiopharmaceutical release.

Where and when to use it

during generator acceptance, elution control, incoming radionuclide QC and investigation of unexpected peaks or impurities. Medical use: oncology and theranostics. Workflow stages: product release QC, generators and isotope purity, imaging QC and quantitative interpretation.

Input fields

RecordID, EnteredBatchNumber, ExpectedBatchNumber, EnteredNuclide, ExpectedNuclide, EnteredActivityMBq, MeasurementDateTime, TechnicianID, WorkstationID, ExpectedActivityMBq

Open utility

Related utilities
Recoil Effect Checker API / calculation and rule-basedGeneral RPH
What it does

Utility assesses consequences of bond rupture during alpha decay: Calculation of Recoil Energy Comparison with chemical bond energy Assessment of free daughter nuclide percentage

Why it is needed

Supports control of the starting radionuclide, generator eluate, breakthrough and radionuclidic purity before final radiopharmaceutical release.

Where and when to use it

during generator acceptance, elution control, incoming radionuclide QC and investigation of unexpected peaks or impurities. Medical use: renal and urinary, oncology and theranostics. Workflow stages: synthesis, labelling and kit reconstitution, product release QC, generators and isotope purity.

Input fields

BatchNumber, ParentIsotope, DaughterIsotope, AlphaEnergyMeV, BondEnergyKcalPerMol, ChelatorStabilityConstant, FreeDaughterPercent, RenalUptakeSUV, TimePostLabelingHours, ProductType

Open utility

Related utilities
Rhenium-186 Quality Checker API / calculation and rule-basedGeneral RPH
What it does

The utility checks RCP, free perrhenate, hydrolyzed rhenium, particle size (colloids), sterility. Does not use machine learning — rule-based logic only. Rhenium186QualityChecker.exe → demo mode Rhenium186QualityChecker.exe input.csv output.json → evaluate data

Why it is needed

Supports control of the starting radionuclide, generator eluate, breakthrough and radionuclidic purity before final radiopharmaceutical release.

Where and when to use it

during generator acceptance, elution control, incoming radionuclide QC and investigation of unexpected peaks or impurities. Medical use: hepatobiliary and GI, endocrine, thyroid and NET, bone and musculoskeletal. Workflow stages: product release QC, generators and isotope purity, dosimetry and therapy planning.

Input fields

BatchNumber, Formulation_Type, Radionuclidic_Purity_Percent, Radiochemical_Purity_Percent, Specific_Activity_MBq_mg, Free_Perrhenate_Percent, Hydrolyzed_Reduced_Re_Percent, Particle_Size_Mean_nm, pH_Value, SterilityTest

Open utility

Related utilities
Rubidium82 Chloride Quality Checker API / calculation and rule-basedRb-82Sr-82
What it does

Utility checks critical parameters of Sr-82/Rb-82 generator eluate: Strontium-82 breakthrough (≤20 Bq/MBq Rb-82) — CRITICAL! Strontium-85 breakthrough (≤500 Bq/MBq Rb-82) Radiochemical purity (≥95%)

Why it is needed

Supports control of the starting radionuclide, generator eluate, breakthrough and radionuclidic purity before final radiopharmaceutical release.

Where and when to use it

during generator acceptance, elution control, incoming radionuclide QC and investigation of unexpected peaks or impurities. Medical use: cardiovascular, bone and musculoskeletal. Workflow stages: product release QC, generators and isotope purity, imaging QC and quantitative interpretation.

Input fields

BatchNumber, ElutedActivityMBq, BreakthroughSr82BqPerMBq, BreakthroughSr85BqPerMBq, RadiochemicalPurityPercent, pH, AppearanceClarity, SterilityTest, EndotoxinsEU, SalineVolumeMl

Open utility

Related utilities
Scandium-47 Quality Checker API / calculation and rule-basedGeneral RPH
What it does

The utility checks RCP, free scandium, long-lived impurities (Sc-46), sterility. Does not use machine learning — rule-based logic only. Scandium47QualityChecker.exe → demo mode Scandium47QualityChecker.exe input.csv output.json → evaluate data

Why it is needed

Supports control of the starting radionuclide, generator eluate, breakthrough and radionuclidic purity before final radiopharmaceutical release.

Where and when to use it

during generator acceptance, elution control, incoming radionuclide QC and investigation of unexpected peaks or impurities. Medical use: hepatobiliary and GI, endocrine, thyroid and NET, oncology and theranostics. Workflow stages: product release QC, generators and isotope purity, dosimetry and therapy planning.

Input fields

BatchNumber, Radiopharmaceutical, Radionuclidic_Purity_Percent, Radiochemical_Purity_Percent, Specific_Activity_MBq_nmol, Free_Scandium_Ion_Percent, Long_Lived_Impurities_Percent, Target_Metal_Residue_ppm, pH_Value, Ethanol_Content_Percent

Open utility

Related utilities
Scandium44 Quality Checker API / calculation and rule-basedGeneral RPH
What it does

Utility checks critical parameters of Scandium-44: Radionuclidic purity (≥99.0%) Scandium-43 impurity (≤1.0%) Scandium-47 impurity (≤0.5%)

Why it is needed

Supports control of the starting radionuclide, generator eluate, breakthrough and radionuclidic purity before final radiopharmaceutical release.

Where and when to use it

during generator acceptance, elution control, incoming radionuclide QC and investigation of unexpected peaks or impurities. Medical use: hepatobiliary and GI, bone and musculoskeletal, oncology and theranostics. Workflow stages: synthesis, labelling and kit reconstitution, product release QC, generators and isotope purity.

Input fields

BatchNumber, TotalActivityMBq, RadionuclidicPurityPercent, Scandium43ImpurityPercent, Scandium47ImpurityPercent, Scandium46ImpurityPercent, RadiochemicalPurityPercent, FreeScandiumPercent, pH, EndotoxinsEU

Open utility

Related utilities
Silver105 Quality Checker API / calculation and rule-basedGeneral RPH
What it does

Utility checks critical parameters of Silver-105: Radionuclidic purity (≥99.0%) Silver-106m impurity (≤0.5%) Silver-110m impurity (≤0.01%) — CRITICAL!

Why it is needed

Supports control of the starting radionuclide, generator eluate, breakthrough and radionuclidic purity before final radiopharmaceutical release.

Where and when to use it

during generator acceptance, elution control, incoming radionuclide QC and investigation of unexpected peaks or impurities. Medical use: hepatobiliary and GI, oncology and theranostics. Workflow stages: synthesis, labelling and kit reconstitution, product release QC, generators and isotope purity.

Input fields

BatchNumber, TotalActivityMBq, RadionuclidicPurityPercent, Silver106mImpurityPercent, Silver110mImpurityPercent, RadiochemicalPurityPercent, FreeSilverPercent, pH, EndotoxinsEU, SterilityTest

Open utility

Related utilities
Strontium82 Breakthrough Checker API / calculation and rule-basedRb-82Sr-82
What it does

Utility checks strontium breakthrough compliance with USP <823>: Sr-82 Limit: ≤20 Bq per 1 MBq Rb-82 Sr-85 Limit: ≤500 Bq per 1 MBq Rb-82 Strontium accumulates in bones and irradiates bone marrow.

Why it is needed

Supports control of the starting radionuclide, generator eluate, breakthrough and radionuclidic purity before final radiopharmaceutical release.

Where and when to use it

during generator acceptance, elution control, incoming radionuclide QC and investigation of unexpected peaks or impurities. Medical use: cardiovascular, bone and musculoskeletal. Workflow stages: product release QC, generators and isotope purity, stability, storage, decay and waste.

Input fields

BatchNumber, Rb82ActivityMBq, Sr82ActivityBq, Sr85ActivityBq, ElutionVolumeMl, TimeSinceCalibrationHours, GeneratorID

Open utility

Related utilities
Tc99m Colloid Checker API / calculation and rule-basedTc-99m
What it does

Utility performs DEEP colloid phase analysis with: Current colloid percentage check (≤5% for most agents) Stability prediction until end of shelf life (6-12 hours) Trend analysis with previous measurements

Why it is needed

Supports control of the starting radionuclide, generator eluate, breakthrough and radionuclidic purity before final radiopharmaceutical release.

Where and when to use it

during generator acceptance, elution control, incoming radionuclide QC and investigation of unexpected peaks or impurities. Medical use: renal and urinary, hepatobiliary and GI, cardiovascular, bone and musculoskeletal. Workflow stages: synthesis, labelling and kit reconstitution, product release QC, generators and isotope purity.

Input fields

BatchNumber, ProductType, ColloidPhasePercent_Current, pH, MeasurementDateTime, RadiolabelingDateTime, StorageTemperatureC, PreviousColloidPhasePercent, PreviousMeasurementDateTime

Open utility

Related utilities
Tc99m HMPAO Quality Checker API / calculation and rule-basedTc-99m
What it does

Utility checks critical parameters of Tc-99m HMPAO: Radiochemical purity of lipophilic complex (≥80%) Secondary complex (≤15%) Free pertechnetate (≤5%)

Why it is needed

Supports control of the starting radionuclide, generator eluate, breakthrough and radionuclidic purity before final radiopharmaceutical release.

Where and when to use it

during generator acceptance, elution control, incoming radionuclide QC and investigation of unexpected peaks or impurities. Medical use: renal and urinary, hepatobiliary and GI, brain and CNS, endocrine, thyroid and NET. Workflow stages: synthesis, labelling and kit reconstitution, product release QC, generators and isotope purity.

Input fields

BatchNumber, TotalActivityMBq, RadiochemicalPurityPercent, SecondaryComplexPercent, FreePertechnetatePercent, ReducedHydrolyzedTcPercent, pH, EndotoxinsEU, SterilityTest, TimeSinceReconstitutionMin

Open utility

Related utilities
Technetium99m ECD Quality Checker API / calculation and rule-basedTc-99m
What it does

Utility checks critical parameters of Tc-99m ECD: Radiochemical purity (≥95%) Free pertechnetate (≤2%) Colloidal technetium (≤3%)

Why it is needed

Supports control of the starting radionuclide, generator eluate, breakthrough and radionuclidic purity before final radiopharmaceutical release.

Where and when to use it

during generator acceptance, elution control, incoming radionuclide QC and investigation of unexpected peaks or impurities. Medical use: renal and urinary, hepatobiliary and GI, cardiovascular, brain and CNS, endocrine, thyroid and NET. Workflow stages: synthesis, labelling and kit reconstitution, product release QC, generators and isotope purity.

Input fields

BatchNumber, TotalActivityMBq, RadiochemicalPurityPercent, FreePertechnetatePercent, ReducedHydrolyzedTcPercent, pH, EndotoxinsEU, SterilityTest, TimeSinceReconstitutionMin, ProductType

Open utility

Related utilities
Technetium99m Exametazime Quality Checker API / calculation and rule-basedTc-99m
What it does

Utility checks critical parameters of Tc-99m HMPAO: Radiochemical purity of lipophilic complex (≥80%) Secondary complex (≤15%) Free pertechnetate (≤5%)

Why it is needed

Supports control of the starting radionuclide, generator eluate, breakthrough and radionuclidic purity before final radiopharmaceutical release.

Where and when to use it

during generator acceptance, elution control, incoming radionuclide QC and investigation of unexpected peaks or impurities. Medical use: hepatobiliary and GI, brain and CNS, endocrine, thyroid and NET, blood, cells and marrow, lymphatic, infection and inflammation. Workflow stages: synthesis, labelling and kit reconstitution, product release QC, generators and isotope purity.

Input fields

BatchNumber, TotalActivityMBq, RadiochemicalPurityPercent, SecondaryComplexPercent, FreePertechnetatePercent, ReducedHydrolyzedTcPercent, pH, EndotoxinsEU, SterilityTest, TimeSinceReconstitutionMin

Open utility

Related utilities
Technetium99m Generator Quality Checker API / calculation and rule-basedTc-99m
What it does

Utility checks critical eluate parameters: molybdenum-99 and iodine-131 breakthrough (calculated as % of Tc-99m activity), eluate volume, eluate pH. Does not use machine learning — only mathematical calculation of breakthrough percentages and pharmacopoeial limit checks. Technetium99mGeneratorQualityChecker.exe → demo mode (console output)

Why it is needed

Supports control of the starting radionuclide, generator eluate, breakthrough and radionuclidic purity before final radiopharmaceutical release.

Where and when to use it

during generator acceptance, elution control, incoming radionuclide QC and investigation of unexpected peaks or impurities. Medical use: renal and urinary, cardiovascular, endocrine, thyroid and NET, bone and musculoskeletal. Workflow stages: synthesis, labelling and kit reconstitution, product release QC, generators and isotope purity.

Input fields

BatchNumber, Tc99mActivityMBq, Mo99ActivityMBq, I131ActivityMBq, EluateVolumeMl, EluatePH

Open utility

Related utilities
Terbium-152 Quality Checker API / calculation and rule-basedGeneral RPH
What it does

The utility checks RCP, long-lived impurities (Tb-155/156), free terbium, specific activity. Does not use machine learning — rule-based logic only. Terbium152QualityChecker.exe → demo mode Terbium152QualityChecker.exe input.csv output.json → evaluate data

Why it is needed

Supports control of the starting radionuclide, generator eluate, breakthrough and radionuclidic purity before final radiopharmaceutical release.

Where and when to use it

during generator acceptance, elution control, incoming radionuclide QC and investigation of unexpected peaks or impurities. Medical use: hepatobiliary and GI, endocrine, thyroid and NET, bone and musculoskeletal, oncology and theranostics. Workflow stages: product release QC, generators and isotope purity.

Input fields

BatchNumber, Radiopharmaceutical, Radionuclidic_Purity_Percent, Radiochemical_Purity_Percent, Specific_Activity_MBq_nmol, Long_Lived_Tb_Impurities_Percent, Free_Terbium_Ion_Percent, Target_Material_Residue_ppm, pH_Value, Ethanol_Content_Percent

Open utility

Related utilities
Thulium170 Quality Checker API / calculation and rule-basedGeneral RPH
What it does

Utility checks critical parameters of Thulium-170: Radionuclidic purity (≥99.5%) Thulium-171 impurity (≤0.1%) — CRITICAL! Ytterbium-175 impurity (≤0.5%)

Why it is needed

Supports control of the starting radionuclide, generator eluate, breakthrough and radionuclidic purity before final radiopharmaceutical release.

Where and when to use it

during generator acceptance, elution control, incoming radionuclide QC and investigation of unexpected peaks or impurities. Medical use: bone and musculoskeletal, lymphatic, infection and inflammation. Workflow stages: product release QC, generators and isotope purity, imaging QC and quantitative interpretation.

Input fields

BatchNumber, TotalActivityMBq, RadionuclidicPurityPercent, Thulium171ImpurityPercent, Ytterbium175ImpurityPercent, RadiochemicalPurityPercent, FreeThuliumPercent, pH, EndotoxinsEU, SterilityTest

Open utility

Related utilities
xenon, ventilation and medical gases 29

Xe-129, Xe-133, Xe-127, hyperpolarization, SEOP, T1, mixing, scavenging, transport, recovery and ventilation imaging.

Open package

API / calculation and rule-based 6

Medical Gas Purity ISO 6145 Checker API / calculation and rule-basedXe-129
What it does

Utility controls gas quality per ISO/USP standards: Oxygen (critical for hyperpolarization) Moisture (critical for equipment) CO2 and hydrocarbons (patient safety)

Why it is needed

Supports gas and ventilation workflows covering gas quality, polarization, delivery, scavenging and related device checks.

Where and when to use it

during gas-mixture release, hyperpolarized-gas preparation, MRI/SPECT ventilation, recovery/scavenging and transport control. Medical use: pulmonary and ventilation. Workflow stages: product release QC, instruments, devices and radiation safety.

Input fields

BatchNumber, ProductName, O2_ppm, N2_ppm, H2O_ppm, CO2_ppm, HC_ppm, Max_O2, Max_H2O, Max_CO2

Open utility

Related utilities
TriMix Gas Composition Verifier API / calculation and rule-basedXe-129
What it does

Utility checks mixing accuracy of Xe / N2 / O2: Deviation of each component from target Absolute oxygen safety level Gas sum balance (100%)

Why it is needed

Supports gas and ventilation workflows covering gas quality, polarization, delivery, scavenging and related device checks.

Where and when to use it

during gas-mixture release, hyperpolarized-gas preparation, MRI/SPECT ventilation, recovery/scavenging and transport control. Medical use: pulmonary and ventilation. Workflow stages: imaging QC and quantitative interpretation.

Input fields

BatchNumber, ProductName, Target_Xe, Target_N2, Target_O2, Measured_Xe, Measured_N2, Measured_O2, Max_Dev, Min_Safe_O2

Open utility

Related utilities
Xe Isotopic Enrichment Verifier API / calculation and rule-basedXe-129
What it does

Utility checks mass spectrometry data against certificate: Xe-129 percentage content Sum of impurity isotopes Mass balance (sum 100%)

Why it is needed

Supports gas and ventilation workflows covering gas quality, polarization, delivery, scavenging and related device checks.

Where and when to use it

during gas-mixture release, hyperpolarized-gas preparation, MRI/SPECT ventilation, recovery/scavenging and transport control. Medical use: pulmonary and ventilation. Workflow stages: product release QC.

Input fields

BatchNumber, ProductName, Xe124, Xe126, Xe128, Xe129, Xe130, Xe131, Xe132, Xe134

Open utility

Related utilities
Xe-127 Production Yield & Purity Analyzer API / calculation and rule-basedI-123Xe-127Xe-129
What it does

Utility controls cyclotron production process of Xe-127: Specific yield (MBq/uAh) Radionuclidic purity (% Xe-127) Impurity levels (Xe-125, I-123)

Why it is needed

Supports gas and ventilation workflows covering gas quality, polarization, delivery, scavenging and related device checks.

Where and when to use it

during gas-mixture release, hyperpolarized-gas preparation, MRI/SPECT ventilation, recovery/scavenging and transport control. Medical use: pulmonary and ventilation. Workflow stages: product release QC, generators and isotope purity, stability, storage, decay and waste.

Input fields

BatchNumber, ProductName, Iodine_Mass_g, Beam_uA, Time_h, Act_Xe127_MBq, Act_Xe125_MBq, Act_I123_MBq, Min_Yield, Max_Xe125_Percent

Open utility

Related utilities
Xe-127 Theranostic Potential Analyzer API / calculation and rule-basedXe-127Xe-129
What it does

Utility evaluates Xe-127 suitability for theranostics: Diagnostic contrast and resolution Patient radiation dose Logistics potential (half-life)

Why it is needed

Supports gas and ventilation workflows covering gas quality, polarization, delivery, scavenging and related device checks.

Where and when to use it

during gas-mixture release, hyperpolarized-gas preparation, MRI/SPECT ventilation, recovery/scavenging and transport control. Medical use: pulmonary and ventilation, oncology and theranostics. Workflow stages: imaging QC and quantitative interpretation, instruments, devices and radiation safety.

Input fields

BatchNumber, ProductName, Contrast_Ratio, Resolution_mm, Dose_uSv_per_MBq, Bio_Half_Life_h, Phys_Half_Life_h, Cost_Usd, Max_Dose, Min_Contrast

Open utility

Related utilities
Xe-129 Isotopic Enrichment Verifier API / calculation and rule-basedXe-129
What it does

Utility checks mass spectrometry data against certificate: Xe-129 percentage content Sum of impurity isotopes Mass balance (sum 100%)

Why it is needed

Supports gas and ventilation workflows covering gas quality, polarization, delivery, scavenging and related device checks.

Where and when to use it

during gas-mixture release, hyperpolarized-gas preparation, MRI/SPECT ventilation, recovery/scavenging and transport control. Medical use: pulmonary and ventilation. Workflow stages: product release QC.

Input fields

BatchNumber, ProductName, Xe124, Xe126, Xe128, Xe129, Xe130, Xe131, Xe132, Xe134

Open utility

Related utilities

Instrumental 12

Hyperpolarization Decay Kinetics Monitor InstrumentalXe-129
What it does

Utility analyzes spin polarization lifetime (T1): Measured T1 calculation Remaining signal life prediction Anomalous decay detection (O2 impurities, bad vials)

Why it is needed

Supports gas and ventilation workflows covering gas quality, polarization, delivery, scavenging and related device checks.

Where and when to use it

during gas-mixture release, hyperpolarized-gas preparation, MRI/SPECT ventilation, recovery/scavenging and transport control. Medical use: pulmonary and ventilation, hepatobiliary and GI. Workflow stages: product release QC, dosimetry and therapy planning, imaging QC and quantitative interpretation.

Input fields

BatchNumber, ProductName, Initial_Pol_Percent, Start_Time_H, Current_Pol_Percent, Elapsed_Time_H, O2_ppm, Wall_Factor, Min_Acceptable_Pol, Expected_T1_H

Open utility

Related utilities
Laser Wavelength & Power Stability Checker InstrumentalXe-129
What it does

Utility controls laser parameters for optical pumping: Wavelength accuracy (atomic transition match) Power stability (noise absence) Thermal drift

Why it is needed

Supports gas and ventilation workflows covering gas quality, polarization, delivery, scavenging and related device checks.

Where and when to use it

during gas-mixture release, hyperpolarized-gas preparation, MRI/SPECT ventilation, recovery/scavenging and transport control. Medical use: pulmonary and ventilation. Workflow stages: dosimetry and therapy planning, imaging QC and quantitative interpretation, stability, storage, decay and waste.

Input fields

BatchNumber, ProductName, Center_Wavelength_nm, Target_Wavelength_nm, Output_Power_W, Target_Power_W, Wavelength_Drift_nm, Power_Fluctuation_Percent, Max_Drift_nm, Max_Fluct_Percent

Open utility

Related utilities
Magnetic Field Homogeneity Mapper InstrumentalXe-129
What it does

Utility analyzes magnetic field map (B0) in polarization volume: Peak frequency deviation (Hz) Root Mean Square inhomogeneity (RMS) Uniformity in ppm

Why it is needed

Supports gas and ventilation workflows covering gas quality, polarization, delivery, scavenging and related device checks.

Where and when to use it

during gas-mixture release, hyperpolarized-gas preparation, MRI/SPECT ventilation, recovery/scavenging and transport control. Medical use: pulmonary and ventilation. Workflow stages: dosimetry and therapy planning, imaging QC and quantitative interpretation, instruments, devices and radiation safety.

Input fields

BatchNumber, ProductName, Central_Freq_Hz, Max_Dev_Hz, RMS_Hz, VOI_Diameter_mm, Max_Allowed_Peak_Hz, Max_Allowed_RMS_Hz

Open utility

Related utilities
MRI Voxel Signal Uniformity Analyzer InstrumentalXe-129
What it does

Utility evaluates HP-gas MRI image quality: Signal Coefficient of Variation (CV) Signal-to-Noise Ratio (SNR) Intensity dynamic range

Why it is needed

Supports gas and ventilation workflows covering gas quality, polarization, delivery, scavenging and related device checks.

Where and when to use it

during gas-mixture release, hyperpolarized-gas preparation, MRI/SPECT ventilation, recovery/scavenging and transport control. Medical use: pulmonary and ventilation. Workflow stages: dosimetry and therapy planning, imaging QC and quantitative interpretation, stability, storage, decay and waste.

Input fields

BatchNumber, ProductName, Mean_Signal, Std_Dev, Max_Signal, Min_Signal, SNR, Max_CV_Percent, Min_SNR

Open utility

Related utilities
Spin-Exchange Optical Pumping Efficiency Monitor InstrumentalXe-129
What it does

Utility evaluates hyperpolarization process quality: Achieved polarization level Signal buildup time Ratio to theoretical limit

Why it is needed

Supports gas and ventilation workflows covering gas quality, polarization, delivery, scavenging and related device checks.

Where and when to use it

during gas-mixture release, hyperpolarized-gas preparation, MRI/SPECT ventilation, recovery/scavenging and transport control. Medical use: pulmonary and ventilation. Workflow stages: dosimetry and therapy planning, imaging QC and quantitative interpretation, stability, storage, decay and waste.

Input fields

BatchNumber, ProductName, Laser_W, Cell_T_C, Rb_Factor, B_Field_G, Initial_Pol_Percent, Buildup_Time_sec, Max_Theoretical_Pol, Min_Acceptable_Pol

Open utility

Related utilities
T1 Relaxation Kinetics Predictor InstrumentalXe-129
What it does

Utility predicts hyperpolarization lifetime: Oxygen impact (paramagnetic quenching) Vial wall quality impact Polarization level prediction at scan time

Why it is needed

Supports gas and ventilation workflows covering gas quality, polarization, delivery, scavenging and related device checks.

Where and when to use it

during gas-mixture release, hyperpolarized-gas preparation, MRI/SPECT ventilation, recovery/scavenging and transport control. Medical use: pulmonary and ventilation. Workflow stages: product release QC, dosimetry and therapy planning, imaging QC and quantitative interpretation.

Input fields

BatchNumber, ProductName, Initial_Pol_Percent, O2_ppm, Temperature_C, Field_T, Surface_Factor, Target_Time_H, Min_Req_Pol

Open utility

Related utilities
T1 Relaxation Time Predictor InstrumentalXe-129
What it does

Utility predicts hyperpolarization lifetime: Oxygen impact (paramagnetic quenching) Vial wall quality impact Polarization level prediction at scan time

Why it is needed

Supports gas and ventilation workflows covering gas quality, polarization, delivery, scavenging and related device checks.

Where and when to use it

during gas-mixture release, hyperpolarized-gas preparation, MRI/SPECT ventilation, recovery/scavenging and transport control. Medical use: pulmonary and ventilation. Workflow stages: product release QC, dosimetry and therapy planning, imaging QC and quantitative interpretation.

Input fields

BatchNumber, ProductName, Initial_Pol_Percent, O2_ppm, Temperature_C, Field_T, Surface_Factor, Target_Time_H, Min_Req_Pol

Open utility

Related utilities
Xe-129 MRI Signal Uniformity Analyzer InstrumentalXe-129
What it does

Utility evaluates HP-gas MRI image quality: Signal Coefficient of Variation (CV) Signal-to-Noise Ratio (SNR) Intensity dynamic range

Why it is needed

Supports gas and ventilation workflows covering gas quality, polarization, delivery, scavenging and related device checks.

Where and when to use it

during gas-mixture release, hyperpolarized-gas preparation, MRI/SPECT ventilation, recovery/scavenging and transport control. Medical use: pulmonary and ventilation. Workflow stages: dosimetry and therapy planning, imaging QC and quantitative interpretation, stability, storage, decay and waste.

Input fields

BatchNumber, ProductName, Mean_Signal, Std_Dev, Max_Signal, Min_Signal, SNR, Max_CV_Percent, Min_SNR

Open utility

Related utilities
Xe-129 Polarization Level Checker InstrumentalXe-129
What it does

Utility controls key parameter of hyperpolarized MRI: Absolute polarization level (%) Signal enhancement factor relative to thermal equilibrium Deviation from target value

Why it is needed

Supports gas and ventilation workflows covering gas quality, polarization, delivery, scavenging and related device checks.

Where and when to use it

during gas-mixture release, hyperpolarized-gas preparation, MRI/SPECT ventilation, recovery/scavenging and transport control. Medical use: pulmonary and ventilation. Workflow stages: dosimetry and therapy planning, imaging QC and quantitative interpretation, stability, storage, decay and waste.

Input fields

BatchNumber, ProductName, Measured_Pol_Percent, Thermal_Signal, HP_Signal, Pumping_Time_Min, Laser_W, Min_Pol, Target_Pol

Open utility

Related utilities
Xe-133 Ventilation Dosimetry & Scavenging QC InstrumentalXe-129Xe-133
What it does

Utility controls radiation safety during Xe-133 use: Patient effective dose Room air gas concentration Exhaled gas scavenging efficiency

Why it is needed

Supports gas and ventilation workflows covering gas quality, polarization, delivery, scavenging and related device checks.

Where and when to use it

during gas-mixture release, hyperpolarized-gas preparation, MRI/SPECT ventilation, recovery/scavenging and transport control. Medical use: renal and urinary, pulmonary and ventilation. Workflow stages: dosimetry and therapy planning, imaging QC and quantitative interpretation, instruments, devices and radiation safety.

Input fields

BatchNumber, ProductName, Admin_MBq, Inhale_Min, Washout_Min, Lung_Dose_mSv, Bladder_Dose_mSv, Total_Dose_mSv, Room_Conc_Bq_m3, Recovery_Percent

Open utility

Related utilities
Xe-133 Ventilation SPECT QC InstrumentalXe-129Xe-133
What it does

Utility evaluates technical parameters of SPECT data acquisition: Total statistics (count number) Detector field of view uniformity Peak count rate

Why it is needed

Supports gas and ventilation workflows covering gas quality, polarization, delivery, scavenging and related device checks.

Where and when to use it

during gas-mixture release, hyperpolarized-gas preparation, MRI/SPECT ventilation, recovery/scavenging and transport control. Medical use: pulmonary and ventilation. Workflow stages: dosimetry and therapy planning, imaging QC and quantitative interpretation, instruments, devices and radiation safety.

Input fields

BatchNumber, ProductName, Admin_MBq, Acq_Time_Min, Matrix, Total_Counts_k, Peak_CPS, Uniformity_Percent, Min_Counts, Max_Unif

Open utility

Related utilities
Xe-O2 Mixing Ratio & Polarization Loss Checker InstrumentalXe-129
What it does

Utility balances between safety (O2) and signal quality (Xe): Polarization loss percentage during mixing Oxygen level (patient safety) Paramagnetic quenching factor

Why it is needed

Supports gas and ventilation workflows covering gas quality, polarization, delivery, scavenging and related device checks.

Where and when to use it

during gas-mixture release, hyperpolarized-gas preparation, MRI/SPECT ventilation, recovery/scavenging and transport control. Medical use: pulmonary and ventilation, hepatobiliary and GI. Workflow stages: dosimetry and therapy planning, imaging QC and quantitative interpretation.

Input fields

BatchNumber, ProductName, Xe_Percent, O2_Percent, Initial_Pol, Final_Pol, Time_Sec, Max_Loss_Percent, Min_O2_Percent

Open utility

Related utilities

Medical devices 11

Exhaled Gas Scavenging & Recovery QC Medical devicesXe-129
What it does

Utility controls economics and safety of gas return process: Collection efficiency (>85%) CO2 and moisture removal Isotopic purity preservation

Why it is needed

Supports gas and ventilation workflows covering gas quality, polarization, delivery, scavenging and related device checks.

Where and when to use it

during gas-mixture release, hyperpolarized-gas preparation, MRI/SPECT ventilation, recovery/scavenging and transport control. Medical use: pulmonary and ventilation.

Input fields

BatchNumber, ProductName, Administered_Volume_L, Exhaled_Captured_Volume_L, Initial_Xe_Purity_Percent, Recovered_Xe_Purity_Percent, Recovered_CO2_ppm, Recovered_H2O_ppm, Recovered_O2_ppm, Min_Recovery_Eff

Open utility

Related utilities
Exhaled Gas Scavenging Efficiency Checker Medical devicesXe-129
What it does

Utility controls balance of administered and collected xenon: Pure Xe-129 volume calculation Collection efficiency (>90%) Breathing circuit leak detection

Why it is needed

Supports gas and ventilation workflows covering gas quality, polarization, delivery, scavenging and related device checks.

Where and when to use it

during gas-mixture release, hyperpolarized-gas preparation, MRI/SPECT ventilation, recovery/scavenging and transport control. Medical use: pulmonary and ventilation.

Input fields

BatchNumber, ProductName, Administered_Volume_L, Captured_Exhaled_Volume_L, Administered_Xe_Conc_Percent, Captured_Xe_Conc_Percent, Min_Efficiency

Open utility

Related utilities
Gas Mixing Ratio & Hypoxia Risk Checker Medical devicesXe-129
What it does

Utility controls breathing mixture safety: Oxygen level (≥19-21%) Xenon level (≤30% for conscious patients) Gas balance (100%)

Why it is needed

Supports gas and ventilation workflows covering gas quality, polarization, delivery, scavenging and related device checks.

Where and when to use it

during gas-mixture release, hyperpolarized-gas preparation, MRI/SPECT ventilation, recovery/scavenging and transport control. Medical use: pulmonary and ventilation, hepatobiliary and GI.

Input fields

BatchNumber, ProductName, Xe_Conc_Percent, O2_Conc_Percent, N2_Conc_Percent, Min_O2_Level, Max_Xe_Level

Open utility

Related utilities
Hyperpolarized Gas Delivery Safety QC Medical devicesXe-129
What it does

Utility monitors gas administration parameters to patient: Volume dosing accuracy Peak airway pressure Flow rate (turbulence)

Why it is needed

Supports gas and ventilation workflows covering gas quality, polarization, delivery, scavenging and related device checks.

Where and when to use it

during gas-mixture release, hyperpolarized-gas preparation, MRI/SPECT ventilation, recovery/scavenging and transport control. Medical use: pulmonary and ventilation, hepatobiliary and GI. Workflow stages: instruments, devices and radiation safety.

Input fields

BatchNumber, ProductName, Delivered_Volume, Target_Volume, Flow_Rate, Peak_Pressure, Max_Pressure, Max_Flow, Min_O2, Measured_O2

Open utility

Related utilities
Patient Hypoxia Risk During Xe Breathing Checker Medical devicesXe-129
What it does

Utility evaluates patient safety during xenon inhalation: Minimum SpO2 level Inspired oxygen concentration (FiO2) Desaturation depth

Why it is needed

Supports gas and ventilation workflows covering gas quality, polarization, delivery, scavenging and related device checks.

Where and when to use it

during gas-mixture release, hyperpolarized-gas preparation, MRI/SPECT ventilation, recovery/scavenging and transport control. Medical use: pulmonary and ventilation.

Input fields

BatchNumber, ProductName, Inspired_O2_Percent, Xe_Conc_Percent, Baseline_SpO2, Hemoglobin, Min_Monitored_SpO2, Avg_Monitored_SpO2, Duration_Sec, Critical_Threshold

Open utility

Related utilities
Room Air Xe Concentration Monitor Medical devicesXe-129
What it does

Utility controls environmental safety in laboratory/cabinet: Xenon concentration (ppm) Calculated oxygen level reduction Ventilation efficiency (ACH)

Why it is needed

Supports gas and ventilation workflows covering gas quality, polarization, delivery, scavenging and related device checks.

Where and when to use it

during gas-mixture release, hyperpolarized-gas preparation, MRI/SPECT ventilation, recovery/scavenging and transport control. Medical use: pulmonary and ventilation.

Input fields

BatchNumber, ProductName, Measured_Xe_ppm, Room_Volume_m3, Ventilation_ACH, Max_Allowed_Xe_ppm, O2_Risk_Threshold

Open utility

Related utilities
Storage Vial Surface Quality Checker Medical devicesXe-129
What it does

Utility evaluates suitability of glass containers for hyperpolarized xenon storage: Wall relaxivity activity Anti-relaxation coating uniformity Paramagnetic impurity content

Why it is needed

Supports gas and ventilation workflows covering gas quality, polarization, delivery, scavenging and related device checks.

Where and when to use it

during gas-mixture release, hyperpolarized-gas preparation, MRI/SPECT ventilation, recovery/scavenging and transport control. Medical use: pulmonary and ventilation. Workflow stages: product release QC, stability, storage, decay and waste, instruments, devices and radiation safety.

Input fields

BatchNumber, ProductName, Relaxivity_ms, Paramag_ppm, Coating_Percent, Roughness_nm, Pressure_Bar, Max_Relaxivity, Min_Coating

Open utility

Related utilities
Transport Shock & Temperature Logger QC Medical devicesXe-129
What it does

Utility checks transport condition recorder data: Maximum and minimum temperature Peak shock loads (G-force) Number of shock events

Why it is needed

Supports gas and ventilation workflows covering gas quality, polarization, delivery, scavenging and related device checks.

Where and when to use it

during gas-mixture release, hyperpolarized-gas preparation, MRI/SPECT ventilation, recovery/scavenging and transport control. Medical use: pulmonary and ventilation, hepatobiliary and GI. Workflow stages: stability, storage, decay and waste.

Input fields

BatchNumber, ProductName, Max_Temp, Min_Temp, Avg_Temp, Max_Shock_G, Shock_Count, Max_Allowed_Temp, Min_Allowed_Temp, Max_Shock

Open utility

Related utilities
Xe Recovery & Recycling Efficiency Analyzer Medical devicesXe-129
What it does

Utility evaluates economics and quality of gas return process: Volume and mass collection efficiency Gas purity after cleaning Financial savings per session

Why it is needed

Supports gas and ventilation workflows covering gas quality, polarization, delivery, scavenging and related device checks.

Where and when to use it

during gas-mixture release, hyperpolarized-gas preparation, MRI/SPECT ventilation, recovery/scavenging and transport control. Medical use: pulmonary and ventilation. Workflow stages: product release QC, stability, storage, decay and waste.

Input fields

BatchNumber, ProductName, Admin_Vol_L, Recovered_Raw_L, Recycled_Pure_L, Init_Purity_Percent, Rec_Purity_Percent, Cost_Per_L, Min_Eff_Percent, Min_Pur_Percent

Open utility

Related utilities
Xe Recovery Efficiency & Recycling QC Medical devicesXe-129
What it does

Utility evaluates economics and quality of gas return process: Volume and mass collection efficiency Gas purity after cleaning Financial savings per session

Why it is needed

Supports gas and ventilation workflows covering gas quality, polarization, delivery, scavenging and related device checks.

Where and when to use it

during gas-mixture release, hyperpolarized-gas preparation, MRI/SPECT ventilation, recovery/scavenging and transport control. Medical use: pulmonary and ventilation. Workflow stages: product release QC, stability, storage, decay and waste.

Input fields

BatchNumber, ProductName, Admin_Vol_L, Recovered_Raw_L, Recycled_Pure_L, Init_Purity_Percent, Rec_Purity_Percent, Cost_Per_L, Min_Eff_Percent, Min_Pur_Percent

Open utility

Related utilities
Xe-O2 Mixture Safety Blender QC Medical devicesXe-129
What it does

Utility checks medical gas blender accuracy: O2 and Xe flow errors Output oxygen concentration (safety) Mixing ratio accuracy

Why it is needed

Supports gas and ventilation workflows covering gas quality, polarization, delivery, scavenging and related device checks.

Where and when to use it

during gas-mixture release, hyperpolarized-gas preparation, MRI/SPECT ventilation, recovery/scavenging and transport control. Medical use: pulmonary and ventilation, hepatobiliary and GI.

Input fields

BatchNumber, ProductName, Target_O2_Flow, Measured_O2_Flow, Target_Xe_Flow, Measured_Xe_Flow, Output_O2_Percent, Min_Safe_O2, Max_Flow_Error

Open utility

Related utilities
PET scanner state, gamma camera and radiation physics 29

The linked medical-device/radiation-physics layer: PET detector QC, normalization, AC map, cross-calibration, TOF, gamma-camera uniformity, source strength and staff dose.

Open package

API / calculation and rule-based 1

Decay Corrector Ex for Ge-68/Ga-68 API / calculation and rule-basedGa-68Ge-68
What it does

Ge-68 and Ga-68 Source Decay Correction. Calculates expected source activity on the check date and compares it with the measured value. activity calculation from half-life and dates. measured-to-expected activity deviation. minimum residual activity check for the selected procedure..

Why it is needed

Supports confirmation of PET scanner, gamma-camera and radiation-physics readiness before data interpretation.

Where and when to use it

daily or periodically per SOP, separate from product release but adjacent to the radiopharmaceutical workflow and result interpretation. Workflow stages: stability, storage, decay and waste, instruments, devices and radiation safety.

Input fields

SourceID, Radionuclide, InitialActivityMBq, CalibrationDate, CheckDate, MeasuredActivityMBq, HalfLifeHours

Open utility

Related utilities

Instrumental 11

Gamma Camera Uniformity Check For Renal InstrumentalTc-99m
What it does

Utility evaluates detector sensitivity uniformity: Integral uniformity (≤5%) Differential uniformity (≤3%) Statistical reliability (≥10 million counts)

Why it is needed

Supports confirmation of PET scanner, gamma-camera and radiation-physics readiness before data interpretation.

Where and when to use it

daily or periodically per SOP, separate from product release but adjacent to the radiopharmaceutical workflow and result interpretation. Medical use: renal and urinary, pulmonary and ventilation, bone and musculoskeletal. Workflow stages: imaging QC and quantitative interpretation, instruments, devices and radiation safety.

Input fields

CameraID, CheckDate, IntegralUniformityPercent, DifferentialUniformityPercent, TotalCounts, EnergyWindowCenterKeV, EnergyWindowWidthPercent, CollimatorType, MaxPixelCount, MinPixelCount

Open utility

Related utilities
PET Blank Sinogram Comparator InstrumentalGeneral RPH
What it does

Reference and Current Blank Sinogram Comparison. Compares summary metrics of the current blank sinogram with the approved scanner baseline. mean count deviation. change in dispersion and uniformity index. maximum local deviation and dead-detector count..

Why it is needed

Supports confirmation of PET scanner, gamma-camera and radiation-physics readiness before data interpretation.

Where and when to use it

daily or periodically per SOP, separate from product release but adjacent to the radiopharmaceutical workflow and result interpretation. Workflow stages: instruments, devices and radiation safety.

Input fields

ScannerID, CheckDate, MeanReferenceCounts, MeanCurrentCounts, StdDevReference, StdDevCurrent, MaxDeviationPercent, DeadDetectorCount, UniformityIndex

Open utility

Related utilities
PET Detector Efficiency Outlier Checker InstrumentalGeneral RPH
What it does

PET Detector Efficiency Outlier Detection. Evaluates detector relative-efficiency dispersion and identifies dead, noisy and affected detector blocks. efficiency coefficient of variation. minimum and maximum relative to the mean. dead/noisy detector counts and affected blocks..

Why it is needed

Supports confirmation of PET scanner, gamma-camera and radiation-physics readiness before data interpretation.

Where and when to use it

daily or periodically per SOP, separate from product release but adjacent to the radiopharmaceutical workflow and result interpretation. Workflow stages: instruments, devices and radiation safety.

Input fields

ScannerID, CheckDate, TotalDetectors, MeanEfficiency, StdDevEfficiency, MinEfficiency, MaxEfficiency, DeadDetectorCount, NoisyDetectorCount, AffectedBlocks

Open utility

Related utilities
PET Detector Pair Normalization Cross-Checker InstrumentalGeneral RPH
What it does

PET Detector-Pair Normalization Factor Cross-Check. Independently checks summary characteristics of vendor normalization factors against a calculated factor set. mean-factor comparison. min/max range and standard deviation. zero, infinite and duplicate LOR detection..

Why it is needed

Supports confirmation of PET scanner, gamma-camera and radiation-physics readiness before data interpretation.

Where and when to use it

daily or periodically per SOP, separate from product release but adjacent to the radiopharmaceutical workflow and result interpretation. Workflow stages: instruments, devices and radiation safety.

Input fields

ScannerID, NormalizationID, CheckDate, TotalLORs, MeanVendorFactor, MeanCalculatedFactor, StdDevFactors, MaxFactor, MinFactor, ZeroOrInfiniteCount

Open utility

Related utilities
PET Energy Window Stability Checker InstrumentalGeneral RPH
What it does

PET Energy-Window Stability Check. Checks the 511-keV photopeak position, energy resolution and configured energy-window parameters. photopeak shift from 511 keV. FWHM energy resolution. window centering and scatter fraction..

Why it is needed

Supports confirmation of PET scanner, gamma-camera and radiation-physics readiness before data interpretation.

Where and when to use it

daily or periodically per SOP, separate from product release but adjacent to the radiopharmaceutical workflow and result interpretation. Workflow stages: stability, storage, decay and waste, instruments, devices and radiation safety.

Input fields

ScannerID, CheckDate, MeasuredPeakEnergyKeV, EnergyResolutionPercent, LowerLevelDiscriminatorKeV, UpperLevelDiscriminatorKeV, RandomsRateKcps, ScatterFractionPercent

Open utility

Related utilities
PET Normalization Acquisition Checker InstrumentalGeneral RPH
What it does

PET Normalization Acquisition Check. Checks whether sufficient statistics were acquired and whether the acquisition is suitable for normalization-factor calculation. total counts and duration. centering and axial coverage. interruptions and zero-count detector blocks..

Why it is needed

Supports confirmation of PET scanner, gamma-camera and radiation-physics readiness before data interpretation.

Where and when to use it

daily or periodically per SOP, separate from product release but adjacent to the radiopharmaceutical workflow and result interpretation. Workflow stages: imaging QC and quantitative interpretation, instruments, devices and radiation safety.

Input fields

ScannerID, AcquisitionID, CheckDate, PhantomType, SourceID, TotalCounts, MinRequiredCounts, AcquisitionDurationMin, MinRequiredDurationMin, IsCentered

Open utility

Related utilities
PET Normalization Factor Distribution Checker InstrumentalGeneral RPH
What it does

PET Normalization Factor Distribution Check. Checks the statistical distribution of normalization factors and the fraction of invalid or outlying values. mean, median and standard deviation. percentile range and min/max. invalid count and outlier fraction..

Why it is needed

Supports confirmation of PET scanner, gamma-camera and radiation-physics readiness before data interpretation.

Where and when to use it

daily or periodically per SOP, separate from product release but adjacent to the radiopharmaceutical workflow and result interpretation. Workflow stages: instruments, devices and radiation safety.

Input fields

ScannerID, NormalizationID, CheckDate, TotalFactors, MeanFactor, MedianFactor, StdDevFactor, MinFactor, MaxFactor, Percentile5

Open utility

Related utilities
PET Normalization Trend Checker InstrumentalGeneral RPH
What it does

PET Normalization and Detector-State Trend Check. Compares the current normalization with the previous run and installation baseline to detect gradual drift. mean-factor drift. CV change. new dead detectors and deviation from baseline..

Why it is needed

Supports confirmation of PET scanner, gamma-camera and radiation-physics readiness before data interpretation.

Where and when to use it

daily or periodically per SOP, separate from product release but adjacent to the radiopharmaceutical workflow and result interpretation. Workflow stages: stability, storage, decay and waste, instruments, devices and radiation safety.

Input fields

ScannerID, CurrentNormID, PreviousNormID, BaselineNormID, CurrentMeanFactor, PreviousMeanFactor, BaselineMeanFactor, CurrentCV, PreviousCV, BaselineCV

Open utility

Related utilities
PET Source Strength Logger InstrumentalGa-68Ge-68
What it does

PET QC Source Activity Log. Links the source, certificate, phantom and PET scanner and compares measured activity with expected activity. certificate and phantom-geometry record. expected-activity calculation. measured deviation and ScannerID linkage..

Why it is needed

Supports confirmation of PET scanner, gamma-camera and radiation-physics readiness before data interpretation.

Where and when to use it

daily or periodically per SOP, separate from product release but adjacent to the radiopharmaceutical workflow and result interpretation. Workflow stages: instruments, devices and radiation safety.

Input fields

SourceID, ScannerID, Radionuclide, CertificateNumber, PhantomGeometry, ReferenceActivityMBq, ReferenceDate, MeasuredActivityMBq, MeasurementDate, HalfLifeHours

Open utility

Related utilities
PET TOF Resolution And Timing Offset Checker InstrumentalGeneral RPH
What it does

PET TOF Resolution and Timing-Offset Check. Checks TOF timing resolution, systematic timing offset and coincidence-window parameters. TOF FWHM in picoseconds. absolute timing offset. coincidence window and randoms fraction..

Why it is needed

Supports confirmation of PET scanner, gamma-camera and radiation-physics readiness before data interpretation.

Where and when to use it

daily or periodically per SOP, separate from product release but adjacent to the radiopharmaceutical workflow and result interpretation. Workflow stages: instruments, devices and radiation safety.

Input fields

ScannerID, CheckDate, TOF_FWHM_Picoseconds, TimingOffset_Picoseconds, CoincidenceWindow_Nanoseconds, RandomsFraction_Percent, SinglesRate_Mcps, CalibrationSource

Open utility

Related utilities
PET/CT Cross-Calibration Checker InstrumentalGeneral RPH
What it does

PET/CT and Dose-Calibrator Cross-Calibration. Compares dose-calibrator activity with activity concentration measured from the PET phantom image. decay correction between calibration and scan. expected activity concentration. recovery/cross-calibration ratio and deviation from unity..

Why it is needed

Supports confirmation of PET scanner, gamma-camera and radiation-physics readiness before data interpretation.

Where and when to use it

daily or periodically per SOP, separate from product release but adjacent to the radiopharmaceutical workflow and result interpretation. Workflow stages: stability, storage, decay and waste, instruments, devices and radiation safety.

Input fields

StudyID, PhantomType, DoseCalibratorActivityMBq, CalibrationTime, ScanStartTime, MeasuredActivityConcentrationBQ_per_ML, PhantomVolumeML, PatientWeightKg, DecayCorrectedDoseMBq

Open utility

Related utilities

Medical devices 17

Activity Prescription Checker Medical devicesAc-225Lu-177
What it does

The utility checks dose per kg body weight, renal function (GFR), cumulative dose, and minimum cycle intervals. Does not use machine learning — clinical protocol rules only (Lu-177, Ac-225). ActivityPrescriptionChecker.exe → demo mode (console output) ActivityPrescriptionChecker.exe input.csv output.json → evaluate your data

Why it is needed

Supports confirmation of PET scanner, gamma-camera and radiation-physics readiness before data interpretation.

Where and when to use it

daily or periodically per SOP, separate from product release but adjacent to the radiopharmaceutical workflow and result interpretation. Medical use: renal and urinary, endocrine, thyroid and NET, bone and musculoskeletal, oncology and theranostics. Workflow stages: dosimetry and therapy planning, instruments, devices and radiation safety.

Input fields

PatientID, WeightKg, HeightCm, GFR_MLMin, PrescribedActivityMBq, Radionuclide, CycleNumber, PreviousDoseMBq, LastTreatmentDate

Open utility

Related utilities
Brachy Source Decay Corrector Medical devicesI-125
What it does

The utility calculates current source activity and corrected dwell time considering physical decay. Supported nuclides: Ir-192 (HDR/PDR), I-125 (LDR seeds), Cs-137. Processing: only the FIRST record in input.csv file. BrachySourceDecayCorrector.exe → demo mode

Why it is needed

Supports confirmation of PET scanner, gamma-camera and radiation-physics readiness before data interpretation.

Where and when to use it

daily or periodically per SOP, separate from product release but adjacent to the radiopharmaceutical workflow and result interpretation. Medical use: hepatobiliary and GI, oncology and theranostics. Workflow stages: dosimetry and therapy planning, stability, storage, decay and waste, instruments, devices and radiation safety.

Input fields

SourceID, Radionuclide, CalibrationActivity, CalibrationDate, ProcedureDate, PlannedDwellTimeSec

Open utility

Related utilities
DVH Comparator Medical devicesGeneral RPH
What it does

The utility compares key DVH metrics (D95, D2, V20, Mean, Max) between the current treatment plan and a reference plan (or clinical constraints). Calculates absolute and relative difference checking against specified tolerances (% and absolute units). Processing: only the FIRST record in input.csv file.

Why it is needed

Supports confirmation of PET scanner, gamma-camera and radiation-physics readiness before data interpretation.

Where and when to use it

daily or periodically per SOP, separate from product release but adjacent to the radiopharmaceutical workflow and result interpretation. Medical use: renal and urinary, pulmonary and ventilation, cardiovascular, oncology and theranostics. Workflow stages: dosimetry and therapy planning, instruments, devices and radiation safety.

Input fields

PatientID, StructureName, MetricType, PlanValue, RefValue, TolerancePercent, ToleranceAbsolute

Open utility

Related utilities
Dwell Time Validator Medical devicesGeneral RPH
What it does

The utility checks correctness of dwell time distribution across source positions in a channel. Controlled parameters: time sum vs plan, anomalous peaks (hot spots), index integrity. Processing: only the FIRST record in input.csv file. DwellTimeValidator.exe → demo mode

Why it is needed

Supports confirmation of PET scanner, gamma-camera and radiation-physics readiness before data interpretation.

Where and when to use it

daily or periodically per SOP, separate from product release but adjacent to the radiopharmaceutical workflow and result interpretation. Workflow stages: dosimetry and therapy planning, instruments, devices and radiation safety.

Input fields

PatientID, ChannelID, TotalPositions, TotalDwellTimeSec, MaxSingleDwellSec, MaxDwellPositionIndex, PlannedTotalTimeSec, MaxAllowedSingleSec

Open utility

Related utilities
Gamma Index Analyzer Medical devicesGeneral RPH
What it does

The utility calculates Gamma Analysis Pass Rate for RT plan verification (VMAT, IMRT, SRS). Evaluates compliance with criteria (e.g., 3%/3mm), absolute number of failed points, and low dose threshold. Processing: only the FIRST record in input.csv file. GammaIndexAnalyzer.exe → demo mode

Why it is needed

Supports confirmation of PET scanner, gamma-camera and radiation-physics readiness before data interpretation.

Where and when to use it

daily or periodically per SOP, separate from product release but adjacent to the radiopharmaceutical workflow and result interpretation. Workflow stages: dosimetry and therapy planning, instruments, devices and radiation safety.

Input fields

PatientID, PlanName, Criteria, TotalPoints, PassingPoints, ThresholdDosePercent, RequiredPassRate, MaxAllowedFailPoints

Open utility

Related utilities
MU Calculator Verifier Medical devicesGeneral RPH
What it does

The utility performs independent manual calculation of Monitor Units (MU) based on basic dosimetric parameters and compares result with Treatment Planning System (TPS) data. Uses simplified formula: MU = Dose / (Output * TPR/TMR * Wedge * Tray). Processing: only the FIRST record in input.csv file. MUCalculatorVerifier.exe → demo mode

Why it is needed

Supports confirmation of PET scanner, gamma-camera and radiation-physics readiness before data interpretation.

Where and when to use it

daily or periodically per SOP, separate from product release but adjacent to the radiopharmaceutical workflow and result interpretation. Workflow stages: dosimetry and therapy planning, instruments, devices and radiation safety.

Input fields

PatientID, FieldName, PrescribedDoseGy, DepthCm, FieldSizeX, FieldSizeY, SSD, TPR_TMR, OutputFactor, WedgeFactor

Open utility

Related utilities
PET AC Map Integrity Checker Medical devicesGeneral RPH
What it does

PET/CT Attenuation-Correction Map Integrity Check. Checks summary metrics of the CT-derived attenuation map before quantitative PET reconstruction. physically plausible HU range. truncation artifacts and body width relative to FOV. invalid voxels and metal presence as a review factor..

Why it is needed

Supports confirmation of PET scanner, gamma-camera and radiation-physics readiness before data interpretation.

Where and when to use it

daily or periodically per SOP, separate from product release but adjacent to the radiopharmaceutical workflow and result interpretation. Medical use: bone and musculoskeletal. Workflow stages: imaging QC and quantitative interpretation, instruments, devices and radiation safety.

Input fields

StudyID, PatientID, MinHU, MaxHU, MeanAirHU, MeanBoneHU, TruncationArtifactsCount, HasMetalImplants, BodyWidthCM, ScannerFOV_CM

Open utility

Related utilities
PET Daily Detector QC Decision Checker Medical devicesGeneral RPH
What it does

Daily PET Detector QC Decision. Combines blank scan, energy calibration, TOF, source and configuration results into one operational decision. mandatory sub-check completeness. critical failure precedence over warnings. PASS, REVIEW, RECALIBRATION or DO NOT USE decision..

Why it is needed

Supports confirmation of PET scanner, gamma-camera and radiation-physics readiness before data interpretation.

Where and when to use it

daily or periodically per SOP, separate from product release but adjacent to the radiopharmaceutical workflow and result interpretation. Workflow stages: product release QC, instruments, devices and radiation safety.

Input fields

ScannerID, CheckDate, BlankScanPass, DeadDetectorsCount, SinogramUniformityCV, EnergyWindowPass, PeakShiftKeV, EnergyResolutionPercent, TofCheckPass, TofResolutionPs

Open utility

Related utilities
PET Normalization File Assignment Checker Medical devicesGeneral RPH
What it does

PET Normalization File Assignment Check. Checks that the study uses an approved normalization file for the correct scanner, software version and detector configuration. ScannerID and detector-configuration match. software-version compatibility and file age. hash integrity and approval status..

Why it is needed

Supports confirmation of PET scanner, gamma-camera and radiation-physics readiness before data interpretation.

Where and when to use it

daily or periodically per SOP, separate from product release but adjacent to the radiopharmaceutical workflow and result interpretation. Workflow stages: instruments, devices and radiation safety.

Input fields

ScannerID, StudyID, AssignedNormFile, NormFileScannerID, NormFileSoftwareVersion, CurrentScannerSoftwareVersion, NormFileCreationDate, FileAgeDays, ExpectedHash, ActualHash

Open utility

Related utilities
Post Therapy Imaging QC Medical devicesGeneral RPH
What it does

The utility assesses suitability of post-therapeutic images (Planar/SPECT/PET) for quantitative dose delivery analysis. Controlled metrics: Signal-to-Background Ratio (TBR), detector uniformity, motion artifacts, noise level. Processing: only the FIRST record in input.csv file. PostTherapyImagingQC.exe → demo mode

Why it is needed

Supports confirmation of PET scanner, gamma-camera and radiation-physics readiness before data interpretation.

Where and when to use it

daily or periodically per SOP, separate from product release but adjacent to the radiopharmaceutical workflow and result interpretation. Medical use: pulmonary and ventilation, hepatobiliary and GI, oncology and theranostics. Workflow stages: dosimetry and therapy planning, imaging QC and quantitative interpretation, instruments, devices and radiation safety.

Input fields

PatientID, Radionuclide, ImageType, TargetToBackgroundRatio, UniformityPercent, MotionArtifactScore, NoiseLevel, ExpectedBiodistribution

Open utility

Related utilities
Shielding Calculator Medical devicesGeneral RPH
What it does

The utility calculates required thickness of shielding barrier (concrete, lead, drywall) or verifies compliance of existing shielding. Uses Transmission Factor method based on Workload (W), Distance (d), Use (U) and Occupancy (T) factors. Processing: only the FIRST record in input.csv file. ShieldingCalculator.exe → demo mode

Why it is needed

Supports confirmation of PET scanner, gamma-camera and radiation-physics readiness before data interpretation.

Where and when to use it

daily or periodically per SOP, separate from product release but adjacent to the radiopharmaceutical workflow and result interpretation. Medical use: bone and musculoskeletal. Workflow stages: dosimetry and therapy planning, instruments, devices and radiation safety.

Input fields

RoomID, BarrierType, WorkloadGyPerWeek, UseFactor, OccupancyFactor, DistanceM, DesignDoseSvPerWeek, ExistingThicknessCm, HVL_Cm, TVL_Cm

Open utility

Related utilities
Small Field Correction Checker Medical devicesGeneral RPH
What it does

The utility verifies correctness of applied detector correction factors ($k_{Q_{clin},Q_{msr}}^{f_{clin},f_{msr}}$) for small fields (SRS, SBRT) by comparing with reference data (IAEA TRS-483). Processing: only the FIRST record in input.csv file. SmallFieldCorrectionChecker.exe → demo mode

Why it is needed

Supports confirmation of PET scanner, gamma-camera and radiation-physics readiness before data interpretation.

Where and when to use it

daily or periodically per SOP, separate from product release but adjacent to the radiopharmaceutical workflow and result interpretation. Medical use: brain and CNS. Workflow stages: dosimetry and therapy planning, instruments, devices and radiation safety.

Input fields

PatientID, FieldName, FieldSizeCm, DetectorType, MeasuredOutputFactor, AppliedCorrectionFactor, ReferenceCorrectionFactor

Open utility

Related utilities
Source Strength Logger Medical devicesGeneral RPH
What it does

The utility maintains log of radiation source status (HDR, LDR, Teletherapy), cross-checking certificate data with current measurements. Controlled parameters: physical decay, cumulative hours, expiry date, activity discrepancy. Processing: only the FIRST record in input.csv file. SourceStrengthLogger.exe → demo mode

Why it is needed

Supports confirmation of PET scanner, gamma-camera and radiation-physics readiness before data interpretation.

Where and when to use it

daily or periodically per SOP, separate from product release but adjacent to the radiopharmaceutical workflow and result interpretation. Workflow stages: dosimetry and therapy planning, stability, storage, decay and waste, instruments, devices and radiation safety.

Input fields

SourceID, Radionuclide, InitialActivity, CalibrationDate, CheckDate, MeasuredActivity, CumulativeHoursUsed, MaxAllowedHours, ExpiryDate

Open utility

Related utilities
Staff Dose Tracker Medical devicesGeneral RPH
What it does

The utility analyzes individual occupational doses, comparing them with established limits (quarterly and annual) per NRB-99/2009 and ICRP recommendations. Identifies hazardous trends (consecutive dose increases) and approaching limits. Processing: only the FIRST record in input.csv file. StaffDoseTracker.exe → demo mode

Why it is needed

Supports confirmation of PET scanner, gamma-camera and radiation-physics readiness before data interpretation.

Where and when to use it

daily or periodically per SOP, separate from product release but adjacent to the radiopharmaceutical workflow and result interpretation. Workflow stages: dosimetry and therapy planning, stability, storage, decay and waste, instruments, devices and radiation safety.

Input fields

EmployeeID, FullName, Category, DoseQuarterMsv, DoseYearMsv, LimitQuarterMsv, LimitYearMsv, ConsecutiveIncreases

Open utility

Related utilities
TG43 Parameter Checker Medical devicesI-125
What it does

The utility checks physical consistency of key TG-43 formalism parameters: dose rate constant (Λ), radial dose function g(r), and anisotropy function F(r,θ). Identifies input errors, impossible physical values, and deviations from typical ranges for Ir-192, I-125, Pd-103. Processing: only the FIRST record in input.csv file.

Why it is needed

Supports confirmation of PET scanner, gamma-camera and radiation-physics readiness before data interpretation.

Where and when to use it

daily or periodically per SOP, separate from product release but adjacent to the radiopharmaceutical workflow and result interpretation. Workflow stages: dosimetry and therapy planning, instruments, devices and radiation safety.

Input fields

SourceModel, Radionuclide, AirKermaStrength, DoseRateConstant, GeometryFactor, RadialDoseFunction, AnisotropyFunction, RadiusCm, AngleDeg

Open utility

Related utilities
Treatment Chart Auditor Medical devicesGeneral RPH
What it does

The utility performs comprehensive check of patient's electronic or paper treatment chart before course start or during treatment. Controlled parameters: presence of all mandatory signatures, prescribed vs plan dose match, date logic, fractionation progress. Processing: only the FIRST record in input.csv file.

Why it is needed

Supports confirmation of PET scanner, gamma-camera and radiation-physics readiness before data interpretation.

Where and when to use it

daily or periodically per SOP, separate from product release but adjacent to the radiopharmaceutical workflow and result interpretation. Medical use: pulmonary and ventilation, hepatobiliary and GI, brain and CNS. Workflow stages: dosimetry and therapy planning, instruments, devices and radiation safety.

Input fields

PatientID, PlanName, PrescribedDoseGy, PlanDoseGy, TotalFractions, DeliveredFractions, StartDate, EndDate, PhysicianSigned, PhysicistSigned

Open utility

Related utilities
TRT Dosimetry Calculator Medical devicesGeneral RPH
What it does

The utility calculates absorbed dose in target organs and OARs based on planar/SPECT imaging data (MIRD method). Computes effective half-life (Teff), cumulated activity, and dose per cycle/GBq. Processing: only the FIRST record in input.csv file. TRTDosimetryCalculator.exe → demo mode

Why it is needed

Supports confirmation of PET scanner, gamma-camera and radiation-physics readiness before data interpretation.

Where and when to use it

daily or periodically per SOP, separate from product release but adjacent to the radiopharmaceutical workflow and result interpretation. Medical use: renal and urinary, bone and musculoskeletal, oncology and theranostics. Workflow stages: dosimetry and therapy planning, imaging QC and quantitative interpretation, stability, storage, decay and waste.

Input fields

PatientID, Radionuclide, TargetOrgan, AdministeredActivityMBq, TimePoint1Hr, Activity1MBq, TimePoint2Hr, Activity2MBq, TimePoint3Hr, Activity3MBq

Open utility

Related utilities

Organs and systems

Compact index. Select a utility name to jump to its full description in the use-case class section.

renal and urinary 59 utilities

Renography, GFR/ERPF, renal uptake, DMSA/MAG3/DTPA and bladder-related workflows.

Open package

pulmonary and ventilation 67 utilities

Lung perfusion, MAA, V/Q, aerosol, xenon ventilation, shunt and pulmonary dosimetry.

Open package

hepatobiliary and GI 130 utilities

HIDA, mebrofenin, gallbladder, gastric emptying, GI transit, bleeding and liver/spleen imaging.

Open package

cardiovascular 20 utilities

Myocardial perfusion, cardiac PET/SPECT, ventricular function, blood-pool and perfusion tracers.

Open package

brain and CNS 45 utilities

Brain perfusion, dopamine transporter, amyloid/tau, receptor imaging and neurological SPECT/PET.

Open package

endocrine, thyroid and NET 70 utilities

Radioiodine, thyroid/parathyroid, somatostatin receptor, MIBG and neuroendocrine workflows.

Open package

bone and musculoskeletal 82 utilities

Bone scintigraphy, MDP/PYP, marrow, bone-pain palliation, skeletal metastases and radiosynovectomy.

Open package

blood, cells and marrow 28 utilities

WBC/RBC/platelet labelling, blood volume, survival, blood-pool and cellular release workflows.

Open package

lymphatic, infection and inflammation 26 utilities

Sentinel node, lymphoscintigraphy, nanocolloid, labelled leukocytes, granulocyte and inflammatory imaging.

Open package

oncology and theranostics 136 utilities

Tumour imaging, PSMA/FAPI/receptor tracers, immuno-PET, targeted radionuclide therapy and radioembolization.

Open package

Back to section start

Isotope families

Compact index. Select a utility name to jump to its full description in the use-case class section.

Tc-99m 87 utilities

Tc-99m radiopharmaceuticals, kit preparation, generator control, SPECT workflows and calculation utilities.

Open package

short-lived PET isotopes 17 utilities

F-18, C-11, N-13, O-15 and related PET production, release and imaging workflows.

Open package

Ga/Ge 18 utilities

Ga-67, Ga-68 and Ge-68: generator, radiolabelling, PET/SPECT and purity workflows.

Open package

radioiodine 16 utilities

I-123, I-124, I-125 and I-131 for diagnostics, therapy, labelling and purity control.

Open package

beta-emitting therapy 35 utilities

Lu-177, Y-90, Ho-166, Re-188, Sm-153, Sr-89, P-32, Cu-67 and Tb-161.

Open package

alpha-emitting therapy 12 utilities

Ac-225, Ra-223, At-211, Bi-213 and Th-227: targeted alpha therapy and daughter/recoil control.

Open package

long-lived PET / immuno-PET 15 utilities

Cu-64, Zr-89, I-124, Mn-52 and Y-86 for antibodies, slow kinetics and extended imaging.

Open package

labelled cells and blood 16 utilities

In-111 and Cr-51 for labelled cells, blood volume, RBC/WBC and survival workflows.

Open package

cardiac perfusion and generator tracers 6 utilities

Rb-82/Sr-82, N-13 and Tl-201 for myocardial perfusion and generator-supported workflows.

Open package

xenon and gas tracers 29 utilities

Xe-127, Xe-129 and Xe-133 for ventilation, hyperpolarized imaging, gas QC and safety.

Open package

Back to section start

Workflow stages

Compact index. Select a utility name to jump to its full description in the use-case class section.

synthesis, labelling and kit reconstitution 96 utilities

Radiolabelling, synthesis, chelation, reducing agent, pH/stoichiometry and kit preparation.

Open package

product release QC 199 utilities

Assay, purity, sterility, endotoxins, pH, impurities, appearance and batch-release checks.

Open package

generators and isotope purity 122 utilities

Generator eluate, breakthrough, radionuclidic purity, isotope mix and starting radionuclides.

Open package

dosimetry and therapy planning 59 utilities

Activity planning, absorbed dose, organ dose, lung shunt, preplanning and therapy verification.

Open package

imaging QC and quantitative interpretation 167 utilities

Acquisition, uptake, clearance, perfusion, transit, ejection fraction, segmentation and quantitative imaging.

Open package

stability, storage, decay and waste 138 utilities

Kinetic stability, shelf life, decay correction, expiry, storage, trend and radioactive waste.

Open package

instruments, devices and radiation safety 67 utilities

PET/gamma-camera state, calibration, detector QC, energy window, TOF, shielding and radiation safety.

Open package

Back to section start

Alphabetical index

Compact index. Select a utility name to jump to its full description in the use-case class section.

Ac-225 Targeted Alpha Therapy QC API / calculation and rule-based
Ac225 Daughter Recoil Analyzer API / calculation and rule-based
Actinium225 Quality Checker API / calculation and rule-based
Actinium225 Radioligand Checker API / calculation and rule-based
Aluminum Fluoride18 F Quality Checker API / calculation and rule-based
Astatine-211 Quality Checker API / calculation and rule-based
Bismuth-213 Quality Checker API / calculation and rule-based
Carbon11 Choline Quality Checker API / calculation and rule-based
Carbon11 Methionine Quality Checker API / calculation and rule-based
Chromium51 EDTA Checker API / calculation and rule-based
Cobalt57 Quality Checker API / calculation and rule-based
Cobalt58 Quality Checker API / calculation and rule-based
Copper-64 Quality Checker API / calculation and rule-based
Copper64 ATSM Quality Checker API / calculation and rule-based
Copper64 DOTATATE Quality Checker API / calculation and rule-based
Copper64 Radioligand Checker API / calculation and rule-based
Copper64 Sarcophagine Quality Checker API / calculation and rule-based
Copper67 Quality Checker API / calculation and rule-based
Cu-64 ATSM Quality Checker API / calculation and rule-based
Cu64 F18 Chelator Stability Monitor API / calculation and rule-based
Daughter Nuclide Ingrowth Calculator API / calculation and rule-based
Decay Corrector API / calculation and rule-based
Decay Corrector Ex for Ge-68/Ga-68 API / calculation and rule-based
Dosimetry Pre-Calculator API / calculation and rule-based
DVH Comparator Medical devices
Dwell Time Validator Medical devices
Erbium-169 Quality Checker API / calculation and rule-based
F-18 PSMA PET Synthesis Quality Checker API / calculation and rule-based
Fluorine18 Amyloid Quality Checker API / calculation and rule-based
Fluorine18 Choline Quality Checker API / calculation and rule-based
Fluorine18 DOPA Quality Checker API / calculation and rule-based
Fluorine18 FDG Quality Checker API / calculation and rule-based
Fluorine18 FES Quality Checker API / calculation and rule-based
Fluorine18 FLT Quality Checker API / calculation and rule-based
Fluorine18 FMISO Quality Checker API / calculation and rule-based
Fluorine18 Na F Quality Checker API / calculation and rule-based
Fluorine18 PSMA Quality Checker API / calculation and rule-based
Fluorine18 Radioligand Checker API / calculation and rule-based
Ga-68 DOTATATE Generator Based QC API / calculation and rule-based
Gallium-67 Citrate Quality Checker API / calculation and rule-based
Gallium68 DOTATATE Quality Checker API / calculation and rule-based
Gallium68 FAPI Quality Checker API / calculation and rule-based
Gallium68 Generator Quality Checker API / calculation and rule-based
Gallium68 HBEDCC Quality Checker API / calculation and rule-based
Gallium68 LNP Tracker Quality Checker API / calculation and rule-based
Gallium68 PSMA Quality Checker API / calculation and rule-based
Gamma Index Analyzer Medical devices
Generator Elution Predictor API / calculation and rule-based
Ho-166 Microsphere Quality Checker API / calculation and rule-based
Holmium-166 Quality Checker API / calculation and rule-based
I-131 Sodium Iodide Therapy QC API / calculation and rule-based
I131 Volatility Extended Checker API / calculation and rule-based
In-111 Octreotide Quality Checker API / calculation and rule-based
In-111 Platelet Labeling Quality Checker API / calculation and rule-based
Indium111 Capromab Pendetide Checker API / calculation and rule-based
Indium111 Pentetreotide Quality Checker API / calculation and rule-based
Indium111 WBC Labeling Checker API / calculation and rule-based
Iodine123 FPCT Quality Checker API / calculation and rule-based
Iodine123 Ioflupane Quality Checker API / calculation and rule-based
Iodine123 MIBG Quality Checker API / calculation and rule-based
Iodine123 Na I Quality Checker API / calculation and rule-based
Iodine124 MAB Quality Checker API / calculation and rule-based
Iodine131 Capsules Quality Checker API / calculation and rule-based
Iodine131 Hippuran Quality Checker API / calculation and rule-based
Iodine131 Lipiodol Quality Checker API / calculation and rule-based
Iodine131 MIBG Quality Checker API / calculation and rule-based
Lead212 Quality Checker API / calculation and rule-based
Lu-177 DOTATATE Therapy Quality Checker API / calculation and rule-based
Lu-177 PSMA Therapy Quality Checker API / calculation and rule-based
Lu177 Oxidation Checker API / calculation and rule-based
Lutetium177 DOTATATE Quality Checker API / calculation and rule-based
Lutetium177 DOTATOC Quality Checker API / calculation and rule-based
Lutetium177 J591 Quality Checker API / calculation and rule-based
Lutetium177 PSMA Quality Checker API / calculation and rule-based
Manganese52 Quality Checker API / calculation and rule-based
Medical Gas Purity ISO 6145 Checker API / calculation and rule-based
Mercury197 Quality Checker API / calculation and rule-based
MU Calculator Verifier Medical devices
Nitrogen13 Ammonia Quality Checker API / calculation and rule-based
Oxygen15 Water Quality Checker API / calculation and rule-based
Palladium103 Quality Checker API / calculation and rule-based
Phosphorus32 Chromic Phosphate Checker API / calculation and rule-based
Phosphorus32 Orthophosphate Checker API / calculation and rule-based
Platinum195m Quality Checker API / calculation and rule-based
Post Therapy Imaging QC Medical devices
PSMA SSTR Radioligand Map Utility API / calculation and rule-based
PSMARadioligand Release Checker API / calculation and rule-based
Ra-223 Dichloride Injection QC API / calculation and rule-based
Radiation Dose Calculator API / calculation and rule-based
Radiochemical Purity Checker API / calculation and rule-based
Radiochemical Purity Profile Checker API / calculation and rule-based
Radiolabeled Nanoparticle Quality Checker API / calculation and rule-based
Radioligand Molar Activity Checker API / calculation and rule-based
Radioligand Stability Trend Checker API / calculation and rule-based
Radiolysis Stability Checker API / calculation and rule-based
Radionuclide Impurity Checker API / calculation and rule-based
Radionuclide Mix Checker API / calculation and rule-based
Radionuclidic Purity Checker API / calculation and rule-based
Radium223 Dichloride Quality Checker API / calculation and rule-based
Rapid Release Sterility Endotoxin Checker API / calculation and rule-based
Re-188 Liposome Quality Checker API / calculation and rule-based
Recoil Effect Checker API / calculation and rule-based
Reducing Agent Stoichiometry Calculator API / calculation and rule-based
Rhenium-186 Quality Checker API / calculation and rule-based
Rhenium-188 Quality Checker API / calculation and rule-based
Rubidium82 Chloride Quality Checker API / calculation and rule-based
Samarium153 EDTMP Quality Checker API / calculation and rule-based
Scandium-47 Quality Checker API / calculation and rule-based
Scandium43 Quality Checker API / calculation and rule-based
Scandium44 Quality Checker API / calculation and rule-based
Shielding Calculator Medical devices
Silver105 Quality Checker API / calculation and rule-based
Sm-153 EDTMP Bone Pain QC API / calculation and rule-based
Source Strength Logger Medical devices
Specific Activity Calculator API / calculation and rule-based
Sr-89 Chloride Palliation QC API / calculation and rule-based
SSTRRadioligand Release Checker API / calculation and rule-based
Staff Dose Tracker Medical devices
Stannous Chloride Solution Stability Checker API / calculation and rule-based
Stannous Ion Concentration QC API / calculation and rule-based
Strontium82 Breakthrough Checker API / calculation and rule-based
Strontium89 Chloride Quality Checker API / calculation and rule-based
Tb-161 Radioligand Quality Checker API / calculation and rule-based
Tb161 Radionuclidic Purity Checker API / calculation and rule-based
Tc-99m Besilesomab Quality Checker API / calculation and rule-based
Tc-99m Disofenin Quality Checker API / calculation and rule-based
Tc-99m DMSA(III) Radiochemical Purity Checker API / calculation and rule-based
Tc-99m DTPA Aerosol Quality Checker API / calculation and rule-based
Tc-99m DTPA Stability And Transchelation Checker API / calculation and rule-based
Tc-99m Glucoheptonate Quality Checker API / calculation and rule-based
Tc-99m HIDA Quality Checker API / calculation and rule-based
Tc-99m HMPAO Brain Perfusion Stability Checker API / calculation and rule-based
Tc-99m HMPAO WBC Labeling Quality Checker API / calculation and rule-based
Tc-99m Labeling Reaction pH Optimization Tool API / calculation and rule-based
Tc-99m MAA Quality Checker API / calculation and rule-based
Tc-99m MAA Radiochemical Purity Checker API / calculation and rule-based
Tc-99m MAG3 Labeling Efficiency Analyzer API / calculation and rule-based
Tc-99m MDP Bone Scan Quality Checker API / calculation and rule-based
Tc-99m Mebrofenin Quality Checker API / calculation and rule-based
Tc-99m Nanocolloid Particle Size Analyzer API / calculation and rule-based
Tc-99m Nanocolloid Quality Checker API / calculation and rule-based
Tc-99m Platelet Labeling Quality Checker API / calculation and rule-based
Tc-99m Sestamibi Cardiac Quality Checker API / calculation and rule-based
Tc-99m Sodium Pertechnetate Quality Checker API / calculation and rule-based
Tc-99m Sulesomab Quality Checker API / calculation and rule-based
Tc-99m Tilmanocept Quality Checker API / calculation and rule-based
Tc99m Colloid Checker API / calculation and rule-based
Tc99m HMPAO Quality Checker API / calculation and rule-based
Tc99m MAG3 Quality Checker API / calculation and rule-based
Tc99m MDP Quality Checker API / calculation and rule-based
Tc99m Sestamibi Quality Checker API / calculation and rule-based
Tc99m Tetrofosmin Quality Checker API / calculation and rule-based
Technetium99m ECD Quality Checker API / calculation and rule-based
Technetium99m Exametazime Quality Checker API / calculation and rule-based
Technetium99m Generator Quality Checker API / calculation and rule-based
Technetium99m Glucoheptonate Checker API / calculation and rule-based
Technetium99m Pyrophosphate Checker API / calculation and rule-based
Technetium99m Red Blood Cell Checker API / calculation and rule-based
Technetium99m Sulfur Colloid Checker API / calculation and rule-based
Terbium-149 Quality Checker API / calculation and rule-based
Terbium-152 Quality Checker API / calculation and rule-based
Terbium-155 Quality Checker API / calculation and rule-based
Terbium-161 Quality Checker API / calculation and rule-based
Terbium161 Radioligand Checker API / calculation and rule-based
TG43 Parameter Checker Medical devices
Thallium201 Chloride Quality Checker API / calculation and rule-based
Theranostic Paired Dose Calculator API / calculation and rule-based
Thorium-227 Quality Checker API / calculation and rule-based
Thulium170 Quality Checker API / calculation and rule-based
Treatment Chart Auditor Medical devices
TriMix Gas Composition Verifier API / calculation and rule-based
TRT Dosimetry Calculator Medical devices
Xe Isotopic Enrichment Verifier API / calculation and rule-based
Xe-127 Production Yield & Purity Analyzer API / calculation and rule-based
Xe-127 Theranostic Potential Analyzer API / calculation and rule-based
Xe-129 Isotopic Enrichment Verifier API / calculation and rule-based
Y-90 Microsphere Radioembolization Checker API / calculation and rule-based
Yttrium86 Quality Checker API / calculation and rule-based
Yttrium90 Glass Microsphere Checker API / calculation and rule-based
Yttrium90 Quality Checker API / calculation and rule-based
Yttrium90 Resin Microsphere Checker API / calculation and rule-based
Zirconium89 DFO Quality Checker API / calculation and rule-based
Zirconium89 Trastuzumab Quality Checker API / calculation and rule-based
Zr-89 Monoclonal Antibody Labeling QC API / calculation and rule-based
FUZKK Pharma Utilities · RPH isotope and class index

Utilities and checked parameters

#API / productUtilityKey checks
1Actinium225actinium225Actinium-225 Quality Checker — Actinium-225 for targeted alpha therapy (TAT) ℹ️ Utility checks critical parameters of actinium-225: • Specific activity (≥500 MBq/μmol for conjugates) • Radiochemical purity (≥95%) • Free…
2Copper67copper67Copper-67 Quality Checker — Copper-67 for targeted radionuclide therapy ℹ️ Utility checks critical parameters of copper-67: • Specific activity (≥100 MBq/μmol for conjugates) • Radiochemical purity (≥95%) • Copper-64 imp…
3Decaydecay correctorDecayCorrector — Radionuclide Decay Correction Utility (Ph. Eur. 0125, USP , IAEA TRS-468) ℹ️ The utility calculates decay-corrected radionuclide activity from calibration time to measurement or administration time. ℹ️ D…
4Fluorine18 FDGfluorine18 fdgquality checkerFluorine-18 FDG Quality Checker — ¹⁸F-FDG (fluorodeoxyglucose) for PET diagnostics (Ph.
5Fluorine18 Na Ffluorine18 na fquality checkerFluorine-18 NaF Quality Checker — Sodium [18F]fluoride for bone PET imaging (Ph.
6Fluorine18 PSMAfluorine18 psmaquality checkerFluorine-18 PSMA Quality Checker — ¹⁸F-PSMA-1007 for prostate cancer PET imaging (Ph.
7Gallium68 DOTATATEgallium68 dotatatequality checkerGallium-68 DOTATATE Quality Checker — ⁶⁸Ga-DOTATATE (NETSPOT®) for neuroendocrine tumor PET imaging (Ph.
8Gallium68 FAPIgallium68 fapiquality checkerGallium-68 FAPI Quality Checker — ⁶⁸Ga-FAPI for PET imaging of tumor stroma ℹ️ Utility checks quality of FAPI (Fibroblast Activation Protein Inhibitor) radiopharmaceutical: • Specific activity (≥50 GBq/μmol) • Radiochemi…
9Gallium68 Generatorgallium68 generatorGallium-68 Generator Quality Checker — ⁶⁸Ge/⁶⁸Ga generator for PET diagnostics (Ph.
10Gallium68 LNP Trackergallium68 lnptracker⚠️ DEPRECATED UTILITY This utility has been REPLACED by the universal version: RadiolabeledNanoparticleQualityChecker.
11Gallium68 PSMAgallium68 psmaquality checkerGallium-68 PSMA Quality Checker — ⁶⁸Ga-PSMA-11 for prostate cancer PET imaging (Ph.
12Generator Elution Predictorgenerator elution predictorGenerator Elution Predictor — Generator elution activity predictor ℹ️ Utility calculates PREDICTED daughter nuclide activity in generator eluate: • Accounts for parent nuclide decay since calibration • Accounts for daugh…
13I131 Volatility Extendedi131 volatility extended checkerI-131 Volatility Extended Checker — Extended volatile iodine control in iodine-131 capsules ℹ️ Utility performs DEEP analysis of volatile iodine with: • Current value check (≤5.
14Iodine131 Capsulesiodine131 capsulesIodine-131 Capsules Quality Checker — Iodine-131 Capsules (radiopharmaceutical for thyroid therapy) (Ph.
15Lead212lead212Lead-212 Quality Checker — Lead-212 for targeted alpha therapy (TAT) ℹ️ Utility checks critical parameters of lead-212: • Specific activity (≥100 MBq/μmol for conjugates) • Radiochemical purity (≥95%) • Daughter nuclides…
16Lu177 Oxidationlu177 oxidation checkerLu-177 Oxidation Checker — Lutetium-177 oxidation control (Lu-177m impurity) ℹ️ Utility performs DEEP analysis of lutetium-177 oxidation with: • Current Lu-177m impurity check (≤0.
17Lutetium177 DOTATATElutetium177 dotatatequality checkerLutetium-177 DOTATATE Quality Checker — Lutetium-177 DOTATATE solution (Lutathera®) (Ph.
18Lutetium177 PSMAlutetium177 psmaquality checkerLutetium-177 PSMA Quality Checker — Lutetium-177 PSMA-617 solution (targeted therapy for prostate cancer) (Ph.
19Radiation Dose Calculatorradiation dose calculatorRadiation Dose Calculator — Patient absorbed dose calculator ℹ️ Utility calculates ESTIMATED absorbed dose based on ICRP data (ICRP 106, 128): • Effective dose (mSv) for overall radiation burden assessment • Target organ…
20Radiochemical Purityradiochemical purity checkerRadiochemical Purity Checker — Universal utility for radiochemical purity calculation (TLC / HPLC) ℹ️ Utility calculates radiochemical purity as (target peak area / total peak area) × 100% from chromatographic analysis d…
21Radiolabeled Nanoparticleradiolabeled nanoparticleRadiolabeled Nanoparticle Quality Checker — Universal QC for radiolabeled nanocarriers ℹ️ Utility checks quality of radiolabeled nanoparticles (liposomes, LNPs, polymer NPs) for research use: • Radionuclide quality: spec…
22Radionuclide Impurityradionuclide impurity checkerRadionuclide Impurity Checker — Universal utility for radionuclide impurity calculation from gamma spectrometry data ℹ️ Utility automatically calculates radionuclide impurity percentage with half-life correction.
23Radionuclide Mixradionuclide mix checkerRadionuclide Mix Checker — Batch and radionuclide mix-up check during manual data entry ℹ️ Utility performs CRITICAL data verification to prevent catastrophic errors: • Batch number verification (entered vs expected) • R…
24Radium223 Dichlorideradium223 dichlorideRadium-223 Dichloride Quality Checker — Radium-223 dichloride solution (Xofigo®) (Ph.
25Strontium89 Chloridestrontium89 chlorideStrontium-89 Chloride Quality Checker — Strontium-89 chloride solution (Metastron®) (Ph.
26Tc99m Colloidtc99m colloid checkerTc-99m Colloid Checker — Colloid phase control in technetium-99m radiopharmaceuticals ℹ️ Utility performs DEEP colloid phase analysis with: • Current colloid percentage check (≤5% for most agents) • Stability prediction…
27Technetium99m Generatortechnetium99m generatorTechnetium-99m Generator Quality Checker — Molybdenum-technetium generator (Ph.
28Yttrium90yttrium90Yttrium-90 Quality Checker — Yttrium-90 for radionuclide therapy ℹ️ Utility checks critical parameters of yttrium-90: • Specific activity (≥1000 MBq/μmol for conjugates) • Radiochemical purity (≥95%) • Yttrium-88 impurit…
29Astatine-211astatine211Utility description: Astatine-211 Astatine-211 Quality Checker — Astatine-211 for targeted alpha therapy ℹ️ Utility checks critical parameters of astatine-211: • Radionuclidic purity (≥99.
30Bismuth-213bismuth213Utility description: Bismuth-213 Bismuth-213 Quality Checker — Bismuth-213 for targeted alpha therapy ℹ️ Utility checks critical parameters of bismuth-213: • Radionuclidic purity (≥99.
31Copper-64copper64Utility description: Copper-64 Copper-64 Quality Checker — Radiopharmaceutical (Ph.
32Dosimetry Pre Calculatordosimetry pre calculatorUtility description: Dosimetry Pre Calculator Dosimetry Pre-Calculator — Radiopharmaceutical Activity and Dose Calculation ℹ️ Calculates activity at injection time, effective dose, and critical organ load.
33Erbium-169erbium169Utility description: Erbium-169 Erbium-169 Quality Checker — Radiocolloid for Synovectomy (Ph.
34Holmium-166holmium166Utility description: Holmium-166 Holmium-166 Quality Checker — Radiopharmaceutical (SIRT/Therapy) (Ph.
35Radiolysis Stability Checkerradiolysis stability checkerUtility description: Radiolysis Stability Checker Radiolysis Stability Checker — Radiopharmaceutical Stability Assessment ℹ️ Predicts RCP drop due to autoradiolysis based on activity, volume, and time.
36Rhenium-186rhenium186Utility description: Rhenium-186 Rhenium-186 Quality Checker — Radiopharmaceutical (Therapy) (Ph.
37Rhenium-188rhenium188Utility description: Rhenium-188 Rhenium-188 Quality Checker — Radiopharmaceutical (Generator-based) (Ph.
38Scandium-47scandium47Utility description: Scandium-47 Scandium-47 Quality Checker — Theranostic Radiopharmaceutical (Ph.
39Specific Activity Calculatorspecific activity calculatorUtility description: Specific Activity Calculator Specific Activity Calculator — Radiopharmaceutical Specific Activity Calculation ℹ️ Calculates specific activity (MBq/nmol) with decay correction.
40Terbium-149terbium149Utility description: Terbium-149 Terbium-149 Quality Checker — Alpha Theranostics (Ph.
41Terbium-152terbium152Utility description: Terbium-152 Terbium-152 Quality Checker — PET Diagnostics (Ph.
42Terbium-155terbium155Utility description: Terbium-155 Terbium-155 Quality Checker — SPECT Diagnostics (Ph.
43Terbium-161terbium161Utility description: Terbium-161 Terbium-161 Quality Checker — Terbium-161 for targeted radionuclide therapy ℹ️ Utility checks critical parameters of terbium-161: • Radionuclidic purity (≥99.
44Thorium-227thorium227Utility description: Thorium-227 Thorium-227 Quality Checker — Alpha Therapy (Ph.
45[18F]AlFaluminum fluoride18 f[18F]AlF Quality Checker — PET Diagnostics (AlF method) (Ph. Eur., USP) ℹ️ The utility checks RCP, free fluoride, residual aluminum, sterility, endotoxins. ℹ️ Does not use machine learning — rule-based logic only. ⚠️ CRI…
46[11C]Cholinecarbon11 choline[11C]Choline Quality Checker — PET Diagnostics (Ph. Eur., USP) ℹ️ The utility checks RCP, residual DMAE, methyl iodide, sterility, endotoxins. ℹ️ Does not use machine learning — rule-based logic only. ⚠️ CRITICAL! RCP ≥9…
47[11C]Methioninecarbon11 methionine[11C]Methionine Quality Checker — PET Diagnostics (Ph. Eur., USP) ℹ️ The utility checks RCP, residual precursor, methyl iodide, sterility, endotoxins. ℹ️ Does not use machine learning — rule-based logic only. ⚠️ CRITICAL…
48Chromium-51 EDTAchromium51 edta checkerChromium-51 EDTA Quality Checker — Chromium-51 EDTA for GFR assessment ℹ️ Utility checks critical parameters of chromium-51 EDTA: • Radiochemical purity (≥95%) — fraction of Cr-51 bound to EDTA • Free chromium-51 (≤5%) —…
49Cobalt-57cobalt57Cobalt-57 Quality Checker — Cobalt-57 for diagnostics and equipment calibration ℹ️ Utility checks critical parameters of cobalt-57: • Radionuclidic purity (≥99.
50Cobalt58cobalt58Cobalt58 Quality Checker — radiopharmaceutical QC utility. Limited source description was provided. The utility shall read input.csv, validate declared fields, apply deterministic acceptance rules defined in the executab…
51Copper-64 ATSMcopper64 atsmCopper-64 ATSM Quality Checker — Copper-64 ATSM for PET Hypoxia Imaging ℹ️ Utility checks critical parameters of [64Cu]Cu-ATSM: • Radionuclidic purity (≥99.
52Copper-64 DOTATATEcopper64 dotatateCopper-64 DOTATATE Quality Checker — Copper-64 DOTATATE for PET Imaging of Neuroendocrine Tumors ℹ️ Utility checks critical parameters of [64Cu]Cu-DOTATATE: • Radionuclidic purity (≥99.
53Copper-64 Sarcophaginecopper64 sarcophagineCopper-64 Sarcophagine Quality Checker — Copper-64 Sarcophagine for Stable PET Imaging ℹ️ Utility checks critical parameters of [64Cu]Cu-Sarcophagine: • Radionuclidic purity (≥99.
54Daughter Nuclide Ingrowth Calculatordaughter nuclide ingrowth calculatorDaughter Nuclide Ingrowth Calculator — Calculator for Daughter Nuclide Accumulation ℹ️ Utility calculates theoretical activity of daughter isotopes in radiopharmaceutical generators: • Supported pairs: Mo-99/Tc-99m, Sr-8…
55Fluorine-18 Amyloidfluorine18 amyloidFluorine-18 Amyloid Quality Checker — Fluorine-18 Amyloid Tracers for Alzheimer's Disease PET Imaging ℹ️ Utility checks critical parameters of F-18 amyloid imaging agents (Florbetapir, Flutemetamol, Florbetaben): • Radio…
56Fluorine-18 Cholinefluorine18 cholineFluorine-18 Choline Quality Checker — Fluorine-18 Choline for PET Oncology ℹ️ Utility checks critical parameters of [18F]Fluorocholine: • Radionuclidic purity (≥99.
57Fluorine-18 DOPAfluorine18 dopaFluorine-18 DOPA Quality Checker — Fluorine-18 DOPA for PET Diagnostics ℹ️ Utility checks critical parameters of [18F]FDOPA: • Radionuclidic purity (≥99.
58Fluorine-18 FESfluorine18 fesFluorine-18 FES Quality Checker — Fluorine-18 FES for PET Imaging of Estrogen Receptors ℹ️ Utility checks critical parameters of [18F]Fluoroestradiol (FES): • Radionuclidic purity (≥99.
59Fluorine-18 FLTfluorine18 fltFluorine-18 FLT Quality Checker — Fluorine-18 FLT for PET Proliferation Imaging ℹ️ Utility checks critical parameters of [18F]FLT (3'-deoxy-3'-[18F]fluorothymidine): • Radionuclidic purity (≥99.
60Fluorine-18 FMISOfluorine18 fmisoFluorine-18 FMISO Quality Checker — Fluorine-18 FMISO for PET Hypoxia Imaging ℹ️ Utility checks critical parameters of [18F]FMISO (Fluoromisonidazole): • Radionuclidic purity (≥99.
61Gallium-68 HBED-CCgallium68 hbedccGallium-68 HBED-CC Quality Checker — Gallium-68 PSMA (HBED-CC) for PET Prostate Cancer Imaging ℹ️ Utility checks critical parameters of [68Ga]Ga-PSMA-11 (HBED-CC): • Radionuclidic purity (≥99.
62Indium-111 Capromab Pendetideindium111 capromab pendetide checkerIndium-111 Capromab Pendetide Quality Checker — Indium-111 Capromab Pendetide (ProstaScint®) ℹ️ Utility checks critical parameters of the monoclonal antibody-based radiopharmaceutical: • Radiochemical purity (≥90%) • Fre…
63Indium-111 Pentetreotideindium111 pentetreotideIndium-111 Pentetreotide Quality Checker — Indium-111 Pentetreotide (OctreoScan®) ℹ️ Utility checks critical parameters of the somatostatin analog radiopharmaceutical: • Radiochemical purity (≥90%) • Free Indium-111 impu…
64Indium-111 WBC Labelingindium111 wbc labeling checkerIndium-111 WBC Labeling Checker — Indium-111 Labeled Leukocytes ℹ️ Utility checks critical parameters of autologous leukocytes labeled with Indium-111: • Labeling efficiency (≥80%) • Free Indium-111 impurity (≤20%) • Cel…
65Iodine-123 FP-CITiodine123 fpctIodine-123 FP-CIT Quality Checker — Ioflupane I-123 (DaTscan®) ℹ️ Utility checks critical parameters of the radiopharmaceutical for dopamine transporter imaging: • Radiochemical purity (≥95%) • Free Iodine-123 impurity (…
66Iodine-123 Ioflupaneiodine123 ioflupaneIodine-123 Ioflupane Quality Checker — Ioflupane I-123 (DaTscan®) ℹ️ Utility checks critical parameters of the radiopharmaceutical for dopamine transporter imaging: • Radiochemical purity (≥95%) • Free Iodine-123 impurit…
67Iodine-123 MIBGiodine123 mibgIodine-123 MIBG Quality Checker — Iodine-123 Metaiodobenzylguanidine ℹ️ Utility checks critical parameters of Iodine-123 MIBG radiopharmaceutical: • Radiochemical purity (≥95%) • Free Iodine-123 impurity (≤5%) • Radionuc…
68Iodine-123 NaIiodine123 na iIodine-123 NaI Quality Checker — Sodium Iodide I-123 ℹ️ Utility checks critical parameters of Sodium Iodide I-123: • Radionuclidic purity (≥99% I-123) • Iodine-124 impurity (≤0.
69Iodine-124 MAbiodine124 mabIodine-124 MAb Quality Checker — Iodine-124 Monoclonal Antibodies (ImmunoPET) ℹ️ Utility checks critical parameters of Iodine-124 labeled monoclonal antibodies: • Radiochemical purity (≥90%) • Free Iodine-124 impurity (≤…
70Iodine-131 Hippuraniodine131 hippuranIodine131 Hippuran Quality Checker — radiopharmaceutical QC utility.
71Iodine-131 Lipiodoliodine131 lipiodolIodine-131 Lipiodol Quality Checker — Iodine-131 Lipiodol for radioembolization and therapy ℹ️ Utility checks critical parameters of Iodine-131 Lipiodol: • Radionuclidic purity (≥99.
72Iodine-131 MIBGiodine131 mibgIodine-131 MIBG Quality Checker — Iodine-131 MIBG for neuroendocrine tumor therapy ℹ️ Utility checks critical parameters of Iodine-131 MIBG: • Radionuclidic purity (≥99.
73Lutetium-177 DOTATOClutetium177 dotatocLutetium-177 DOTATOC Quality Checker — Lutetium-177 DOTATOC for Peptide Receptor Radionuclide Therapy (PRRT) ℹ️ Utility checks critical parameters of Lutetium-177 DOTATOC: • Radionuclidic purity (≥99.
74Lutetium-177 J591lutetium177 j591Lutetium-177 J591 Quality Checker — Lutetium-177 J591 (Anti-PSMA mAb) for prostate cancer therapy ℹ️ Utility checks critical parameters of Lutetium-177 J591: • Radionuclidic purity (≥99.
75Manganese-52manganese52Manganese-52 Quality Checker — Manganese-52 for PET Imaging and Research ℹ️ Utility checks critical parameters of Manganese-52: • Radionuclidic purity (≥99.
76Mercury-197mercury197Mercury-197 Quality Checker — Mercury-197 for Renal Imaging ℹ️ Utility checks critical parameters of Mercury-197: • Radionuclidic purity (≥99.
77Nitrogen-13 Ammonianitrogen13 ammoniaNitrogen-13 Ammonia Quality Checker — Nitrogen-13 Ammonia for Cardiac PET Imaging ℹ️ Utility checks critical parameters of [13N]Ammonia: • Radionuclidic purity (≥99.
78Oxygen-15 Wateroxygen15 waterOxygen-15 Water Quality Checker — Oxygen-15 Water for PET Perfusion ℹ️ Utility checks critical parameters of [15O]Water: • Radionuclidic purity (≥99.
79Palladium-103palladium103Palladium-103 Quality Checker — Palladium-103 for Brachytherapy ℹ️ Utility checks critical parameters of Palladium-103: • Radionuclidic purity (≥99.
80Phosphorus-32 Chromic Phosphatephosphorus32 chromic phosphate checkerPhosphorus-32 Chromic Phosphate Quality Checker — P-32 Colloid for Radiosynovectomy ℹ️ Utility checks critical parameters of colloidal Phosphorus-32: • Radionuclidic purity (≥99.
81Phosphorus-32 Orthophosphatephosphorus32 orthophosphate checkerPhosphorus-32 Orthophosphate Quality Checker — P-32 Orthophosphate Solution for Systemic Therapy ℹ️ Utility checks critical parameters of Phosphorus-32 solution: • Radionuclidic purity (≥99.
82Platinum-195mplatinum195mPlatinum-195m Quality Checker — Platinum-195m for Theranostics and Research ℹ️ Utility checks critical parameters of Platinum-195m: • Radionuclidic purity (≥99.
83Recoil Effectrecoil effect checkerRecoil Effect Checker — Recoil Effect Analyzer in Alpha Therapy ℹ️ Utility assesses consequences of bond rupture during alpha decay: • Calculation of Recoil Energy • Comparison with chemical bond energy • Assessment of f…
84Rubidium-82 Chloriderubidium82 chlorideRubidium-82 Chloride Quality Checker — Rubidium-82 Chloride for Myocardial PET Perfusion ℹ️ Utility checks critical parameters of Sr-82/Rb-82 generator eluate: • Strontium-82 breakthrough (≤20 Bq/MBq Rb-82) — CRITICAL!
85Samarium-153 EDTMPsamarium153 edtmpSamarium-153 EDTMP Quality Checker — Samarium-153 EDTMP (Quadramet) for Palliative Therapy ℹ️ Utility checks critical parameters of Samarium-153 EDTMP: • Radionuclidic purity (≥99.
86Scandium-43scandium43Scandium-43 Quality Checker — Scandium-43 for PET Imaging (Theranostics) ℹ️ Utility checks critical parameters of Scandium-43: • Radionuclidic purity (≥99.
87Scandium-44scandium44Scandium-44 Quality Checker — Scandium-44 for PET Imaging (Long Kinetics) ℹ️ Utility checks critical parameters of Scandium-44: • Radionuclidic purity (≥99.
88Silver-105silver105Silver-105 Quality Checker — Silver-105 for Theranostics and PET ℹ️ Utility checks critical parameters of Silver-105: • Radionuclidic purity (≥99.
89Strontium-82 Breakthroughstrontium82 breakthrough checkerStrontium-82 Breakthrough Checker — Strontium-82 Breakthrough Analyzer (Rb-82 Generators) ℹ️ Utility checks strontium breakthrough compliance with USP : • Sr-82 Limit: ≤20 Bq per 1 MBq Rb-82 • Sr-85 Limit: ≤500 Bq per 1…
90Tc-99m HMPAOtc99m hmpaoTc-99m HMPAO Quality Checker — Technetium-99m HMPAO for Brain SPECT Perfusion ℹ️ Utility checks critical parameters of Tc-99m HMPAO: • Radiochemical purity of lipophilic complex (≥80%) • Secondary complex (≤15%) • Free p…
91Tc-99m MAG3tc99m mag3Tc-99m MAG3 Quality Checker — Technetium-99m Mercaptide (MAG3) for Dynamic Renal Scintigraphy ℹ️ Utility checks critical parameters of Tc-99m MAG3: • Radiochemical purity (≥90%) • Free pertechnetate (≤5%) • Colloidal tec…
92Tc-99m MDPtc99m mdpTc-99m MDP Quality Checker — Technetium-99m MDP for Bone Scintigraphy ℹ️ Utility checks critical parameters of Tc-99m MDP: • Radiochemical purity (≥95%) • Free pertechnetate (≤5%) • Colloidal technetium (≤5%) • Aluminum…
93Tc-99m Sestamibitc99m sestamibiTc-99m Sestamibi Quality Checker — Technetium-99m Sestamibi (MIBI) for Cardiology and Surgery ℹ️ Utility checks critical parameters of Tc-99m Sestamibi: • Radiochemical purity (≥90%) • Free pertechnetate (≤5%) • Colloida…
94Tc-99m Tetrofosmintc99m tetrofosminTc-99m Tetrofosmin Quality Checker — Technetium-99m Tetrofosmin for Myocardial Scintigraphy ℹ️ Utility checks critical parameters of Tc-99m Tetrofosmin: • Radiochemical purity (≥90%) • Free pertechnetate (≤5%) • Colloida…
95Tc-99m ECDtechnetium99m ecdTc-99m ECD Quality Checker — Technetium-99m Bicisate (ECD) for Brain SPECT Perfusion ℹ️ Utility checks critical parameters of Tc-99m ECD: • Radiochemical purity (≥95%) • Free pertechnetate (≤2%) • Colloidal technetium (≤…
96Tc-99m Exametazimetechnetium99m exametazimeTc-99m Exametazime Quality Checker — Technetium-99m Exametazime (HMPAO) for Brain and WBCs ℹ️ Utility checks critical parameters of Tc-99m HMPAO: • Radiochemical purity of lipophilic complex (≥80%) • Secondary complex (≤…
97Tc-99m Glucoheptonatetechnetium99m glucoheptonate checkerTc-99m Glucoheptonate Quality Checker — Technetium-99m Glucoheptonate for Brain and Kidneys ℹ️ Utility checks critical parameters of Tc-99m Glucoheptonate: • Radiochemical purity (≥90%) • Free pertechnetate (≤5%) • Collo…
98Tc-99m PYPtechnetium99m pyrophosphate checkerTc-99m PYP Quality Checker — Technetium-99m Pyrophosphate (PYP) for Bones and Heart ℹ️ Utility checks critical parameters of Tc-99m PYP: • Radiochemical purity (≥95%) • Free pertechnetate (≤5%) • Colloidal technetium (≤5…
99Tc-99m RBCtechnetium99m red blood cell checkerTc-99m RBC Quality Checker — Technetium-99m Labeled Red Blood Cells for Heart and GI Tract ℹ️ Utility checks critical parameters of Tc-99m RBC: • Labeling efficiency (≥95%) • Free pertechnetate (≤3%) • Colloidal techneti…
100Tc-99m Sulfur Colloidtechnetium99m sulfur colloid checkerTc-99m Sulfur Colloid Quality Checker — Technetium-99m Sulfur Colloid ℹ️ Utility checks critical parameters of Tc-99m Sulfur Colloid: • Radiochemical purity (≥92%) • Particle size (depends on application: liver/lymph) •…
101Thallium-201 Chloridethallium201 chlorideThallium-201 Chloride Quality Checker — Thallium-201 Chloride for Cardiology and Oncology ℹ️ Utility checks critical parameters of Thallium-201: • Radionuclidic purity (≥99.
102Thulium-170thulium170Thulium-170 Quality Checker — Thulium-170 for Synovitis Therapy and Palliative Care ℹ️ Utility checks critical parameters of Thulium-170: • Radionuclidic purity (≥99.
103Yttrium-86yttrium86Yttrium-86 Quality Checker — Yttrium-86 for PET Dosimetry (Theranostics with Y-90) ℹ️ Utility checks critical parameters of Yttrium-86: • Radionuclidic purity (≥99.
104Yttrium-90 Glass Microsphereyttrium90 glass microsphere checkerYttrium-90 Glass Microsphere Quality Checker — Yttrium-90 Glass Microspheres (TheraSphere) ℹ️ Utility checks critical parameters of Y-90 Glass Microspheres: • Particle size (20–30 μm) — strict!
105Yttrium-90 Resin Microsphereyttrium90 resin microsphere checkerYttrium-90 Resin Microsphere Quality Checker — Yttrium-90 Resin Microspheres (SIR-Spheres) ℹ️ Utility checks critical parameters of Y-90 Resin Microspheres: • Particle size (20–60 μm) • Number of particles (important for…
106Zirconium-89 DFOzirconium89 dfoZirconium-89 DFO Quality Checker — Zirconium-89 DFO for Immuno-PET ℹ️ Utility checks critical parameters of Zr-89-DFO: • Radionuclidic purity (≥99.
107Zirconium-89 Trastuzumabzirconium89 trastuzumabZirconium-89 Trastuzumab Quality Checker — Zirconium-89 Trastuzumab for HER2-PET ℹ️ Utility checks critical parameters of Zr-89-Trastuzumab: • Immunoreactivity (≥80%) — MAIN PARAMETER!