RadiochemicalPurityChecker

Radiochemical Purity

capsules decay correction endotoxins impurities PET radionuclide purity radiopharma SPECT
Open selection
Radiochemical Purity Checker — Universal utility for radiochemical purity calculation (TLC / HPLC)

ℹ️  Utility calculates radiochemical purity as (target peak area / total peak area) × 100% from chromatographic analysis data.
ℹ️  Supports both methods: TLC (Thin Layer Chromatography) and HPLC (High Performance Liquid Chromatography).
ℹ️  Does not use machine learning — only mathematical calculation and interpretation based on pharmaceutical standards.

Usage:
  RadiochemicalPurityChecker.exe                            → demo mode (console output)
  RadiochemicalPurityChecker.exe input.csv output.json      → calculate with your data

Input format:
BatchNumber,AnalysisType,TargetPeakArea,TotalPeakArea,RfValue

Field explanation:
• BatchNumber — product batch number
• AnalysisType — analysis type: "TLC" or "HPLC" (case insensitive)
• TargetPeakArea — area of target peak/spot (units don't matter, ratio is key)
• TotalPeakArea — total area of ALL peaks/spots in chromatogram
• RfValue — (optional) Rf value for TLC (not used in purity calculation, for information only)

Examples:
  RCP-TLC-001,TLC,9500,10000,0.45       ← for TLC with Rf value
  RCP-HPLC-001,HPLC,9850,10000,          ← for HPLC (Rf field empty)

— HOW IT WORKS?
1. Utility validates input data:
   • TotalPeakArea > 0
   • 0 ≤ TargetPeakArea ≤ TotalPeakArea
2. Calculates radiochemical purity: (TargetPeakArea / TotalPeakArea) × 100%
3. Interprets result based on common pharmaceutical standards:
   • ≥98.0% — EXCELLENT (meets Lutathera®/DOTATATE specification)
   • ≥95.0% — GOOD (meets PSMA, Iodine-131, Radium-223 specification)
   • ≥90.0% — ACCEPTABLE (meets diagnostic agents specification)
   • ≥85.0% — MARGINAL (requires investigation)
   • <85.0% — UNACCEPTABLE (product fails specification)
4. Outputs recommendation with interpretation and reminder to compare with product-specific specification.

⚠️ IMPORTANT:
• Radiochemical purity is a CRITICAL quality parameter for radiopharmaceuticals!
• Low purity means presence of radioactive impurities that:
  — Increase patient radiation dose without therapeutic effect
  — Reduce treatment efficacy
  — May accumulate in non-target organs
• Utility does NOT replace official analysis but allows rapid assessment of chromatography results.
• FINAL decision on product suitability is made by comparing with approved specification for specific product.

📌 Recommended radiochemical purity limits for common products:
• Lutetium-177 DOTATATE (Lutathera®): ≥98.0%
• Lutetium-177 PSMA-617: ≥95.0%
• Iodine-131 capsules: ≥95.0%
• Radium-223 dichloride (Xofigo®): ≥95.0%
• Technetium-99m diagnostic agents: ≥90.0%

💡 Usage tips:
• For TLC: ensure spot areas are measured correctly (using densitometer or software)
• For HPLC: use peak integration from chromatography software
• TotalPeakArea must include ALL peaks/spots, including impurities and background
• When using validated analytical methods, utility speeds up result processing 5-10x

input.csv

BatchNumber,AnalysisType,TargetPeakArea,TotalPeakArea,RfValue
RCP-TLC-001,TLC,9500,10000,0.45
RCP-HPLC-001,HPLC,9850,10000,
RCP-TEST-003,TLC,8500,10000,0.38

URS & FS — user requirements and functional specification

This document defines user requirements and functional specification for the quality-control utility. It supports deployment discussion, IQ/OQ preparation and QC workflow integration.

Utility: RadiochemicalPurityCheckerAPI / object: Radiochemical PurityCategory: Radiopharmaceuticals

1. Scope

The Radiochemical Purity Checker utility is used for Radiochemical Purity. The actual input.csv is the source of truth for the input structure; control criteria are defined by the executable and the domain description.

The utility does not use machine learning; decisions are produced by deterministic rules.

Categories: Radiopharmaceuticals

Tags: capsules, decay correction, endotoxins, impurities, PET, radionuclide purity, radiopharma, SPECT, sterility

2. Execution modes

RadiochemicalPurityChecker.exe                            → demo mode (console output)
RadiochemicalPurityChecker.exe input.csv output.json      → calculate with your data

3. Key controlled areas

  • purity and impurities
  • microbiology and pathogens
  • pH and physicochemical parameters
  • activity, decay and radiochemical purity

4. Domain limits and critical parameters

  • TotalPeakArea > 0
  • 0 ≤ TargetPeakArea ≤ TotalPeakArea
  • ≥98.0% — EXCELLENT (meets Lutathera®/DOTATATE specification)
  • ≥95.0% — GOOD (meets PSMA, Iodine-131, Radium-223 specification)
  • ≥90.0% — ACCEPTABLE (meets diagnostic agents specification)
  • ≥85.0% — MARGINAL (requires investigation)
  • <85.0% — UNACCEPTABLE (product fails specification)
  • ⚠️ IMPORTANT:
  • Lutetium-177 DOTATATE (Lutathera®): ≥98.0%
  • Lutetium-177 PSMA-617: ≥95.0%
  • Iodine-131 capsules: ≥95.0%
  • Radium-223 dichloride (Xofigo®): ≥95.0%
  • Technetium-99m diagnostic agents: ≥90.0%
Limits stated in the description must be verified against the current approved specification, pharmacopoeial monograph and registration dossier before production use.

5. URS — user requirements

IDRequirementCriticalityAcceptance criterion
URS-001The system shall accept an input.csv file for Radiochemical Purity with the exact columns listed in the “Input data contract” section.HighA file with the correct header is processed without manual editing; missing mandatory columns produce FAIL/import error.
URS-002The system shall support execution without arguments in demo mode and execution with input.csv output.json for user data.MediumBoth execution scenarios produce a predictable result or clear diagnostic error.
URS-003The system shall perform rule-based controls for: purity and impurities, microbiology and pathogens, pH and physicochemical parameters, activity, decay and radiochemical purity.HighEach controlled parameter receives a status and message; the result does not depend on hidden Excel formulas or ML.
URS-004The system shall preserve traceability between batch/lot, source values, applied rules and final verdict.HighOutput includes batch identifier, source values, parameter statuses and critical findings.
URS-005The system shall generate machine-readable output.json for LIMS/ELN/MES, batch record and QA/QC review.HighJSON contains overall status, check array, warnings, failures and source-file reference.
URS-006The system shall support use in the client validation package: URS/FS, IQ/OQ preparation, installation and operational scenario checks.HighThe document, test scenarios and reproducible CSV/JSON flow are suitable for audit and internal approval.
URS-007The system shall clearly separate technical data errors from specification nonconformities.MediumSchema/type errors are not mixed with pharmacopoeial deviations and are reported separately.

6. input.csv data contract

The source of truth for the input schema is the actual input.csv header. Column names are technical identifiers and are not translated.

#ColumnTypeUnitDescriptionSampleControl rule
1BatchNumberidentifieras specifiedBatch NumberRCP-TLC-001mandatory field; used for batch/lot traceability
2AnalysisTypetextas specifiedAnalysis TypeTLCmandatory value; format and acceptability are checked by the utility
3TargetPeakAreadecimalas specifiedTarget Peak Area9500mandatory numeric value; rule comparison is performed by the utility
4TotalPeakAreadecimalas specifiedTotal Peak Area10000mandatory numeric value; rule comparison is performed by the utility
5RfValuedecimalas specifiedRf Value0.45mandatory numeric value; rule comparison is performed by the utility

CSV example

BatchNumber,AnalysisType,TargetPeakArea,TotalPeakArea,RfValue
RCP-TLC-001,TLC,9500,10000,0.45

7. FS — functional specification

IDFunctionImplementation description
FS-001CLI entry pointThe executable RadiochemicalPurityChecker.exe supports demo mode and input.csv output.json processing mode.
FS-002CSV parserThe import module reads CSV, validates header, column presence/order, value count and encoding. Decimal values are expected with a dot separator.
FS-003Field conversionEach column is converted to the expected type: identifier, text, decimal number, date/time or boolean flag.
FS-004Domain rule engineFor Radiochemical Purity, explicit rules are applied: range, minimum, maximum, absence of prohibited flag, data completeness or calculation-based check.
FS-005Criticality handlingCritical violations produce FAIL; non-critical deviations and incomplete data produce WARNING; full conformance produces PASS.
FS-006JSON writeroutput.json stores overall status, per-parameter results, source values, warnings, failures and diagnostic messages.
FS-007Integration contractThe CSV → JSON format is stable for invocation from LIMS/ELN/MES, scheduled task or wrapper service.
FS-008Error handlingSchema error, missing file, non-numeric value or JSON write failure returns diagnosable error without silent PASS.

8. output.json contract

The output file must be suitable for automated processing, audit review and correlation with the source input.csv row.

{
  "utility": "RadiochemicalPurityChecker",
  "api": "Radiochemical Purity",
  "batchNumber": "RCP-TLC-001",
  "overallStatus": "PASS|WARNING|FAIL",
  "checkedAtUtc": "2026-05-18T00:00:00Z",
  "checks": [
    {
      "parameter": "BatchNumber",
      "value": "RCP-TLC-001",
      "unit": "as specified",
      "status": "PASS|WARNING|FAIL",
      "message": "Rule-based check result"
    },
    {
      "parameter": "AnalysisType",
      "value": "TLC",
      "unit": "as specified",
      "status": "PASS|WARNING|FAIL",
      "message": "Rule-based check result"
    },
    {
      "parameter": "TargetPeakArea",
      "value": "9500",
      "unit": "as specified",
      "status": "PASS|WARNING|FAIL",
      "message": "Rule-based check result"
    },
    {
      "parameter": "TotalPeakArea",
      "value": "10000",
      "unit": "as specified",
      "status": "PASS|WARNING|FAIL",
      "message": "Rule-based check result"
    },
    {
      "parameter": "RfValue",
      "value": "0.45",
      "unit": "as specified",
      "status": "PASS|WARNING|FAIL",
      "message": "Rule-based check result"
    }
  ],
  "criticalFindings": [],
  "sourceFile": "input.csv"
}

9. OQ/PQ test scenarios

IDScenarioExpected result
TC-001Valid CSV with expected header and sample rowAll rows are processed; output contains PASS/WARNING/FAIL and parameter-level detail.
TC-002A mandatory input.csv column is missingImport is rejected or the row receives FAIL with schema reference.
TC-003A numeric field contains text or a blank valueType conversion error is recorded; the result is not hidden as PASS.
TC-004A parameter is outside specification or critical limitCritical parameters produce FAIL; non-critical deviations produce WARNING according to the rule.

10. QA/QC, CSV and change control

  • Before production use, the client records executable version, checksum, specification/monograph version, test CSV, expected JSON and IQ/OQ results.
  • Column names must not be changed without updating the validator and test scenarios.
  • The source CSV, output.json and utility version should be stored together as an evidence package.
  • Any change in control rules must go through change control and repeated OQ scenario verification.

Included in packages

Endocrinology QC Suite

QC package for endocrinology: thyroid, pituitary/peptide hormones, corticosteroids, sex hormones and selected metabolic medicines.

Open

PetRad QC Suite

A specialised utility package for radiopharmaceutical quality control: PET, SPECT, therapeutic radionuclides, generators and decay calculations.

Open

Radiology QC Suite

QC package for radiology and diagnostic imaging: radiopharmaceuticals, PET/SPECT, contrast media, iodinated and gadolinium products, plus particle, sterility and endotoxin checks.

Open

RPH organ/system: endocrine, thyroid and NET

Radioiodine, thyroid/parathyroid, somatostatin receptor, MIBG and neuroendocrine workflows.

Open

RPH organ/system: oncology and theranostics

Tumour imaging, PSMA/FAPI/receptor tracers, immuno-PET, targeted radionuclide therapy and radioembolization.

Open

RPH use case: generators, isotope purity and starting radionuclides

Control of generator eluate, breakthrough, radionuclidic purity, isotope mix, carrier/free radionuclides and starting radionuclides before labeling.

Open

RPH workflow: generators and isotope purity

Generator eluate, breakthrough, radionuclidic purity, isotope mix and starting radionuclides.

Open

RPH workflow: product release QC

Assay, purity, sterility, endotoxins, pH, impurities, appearance and batch-release checks.

Open

RPH workflow: stability, storage, decay and waste

Kinetic stability, shelf life, decay correction, expiry, storage, trend and radioactive waste.

Open

RPH: combined radiopharmaceutical QC package

RPH combines PetRad, PetRad2 and PetRad3 into one umbrella package for PET/SPECT, therapeutic radionuclides, generators, labelled compounds, decay calculations, sterility, endotoxins and radiochemical/radionuclidic purity.

Open