Copper64ATSMQualityChecker

Copper-64 ATSM

radiopharmaceuticals QC URS & FS input.csv output.json radiochemical purity radionuclidic purity PET
Open selection

Utility description: Copper-64 ATSM

Copper-64 ATSM Quality Checker — Copper-64 ATSM for PET Hypoxia Imaging

ℹ️  Utility checks critical parameters of [64Cu]Cu-ATSM:
    • Radionuclidic purity (≥99.9%)
    • Radiochemical purity (≥95%)
    • Free Copper-64 impurity (≤2.0%)
    • ATSM Ligand impurity (≤5.0%)
    • Specific activity (≥10 GBq/μmol)
    • pH, endotoxins, sterility, heavy metals

⚠️  CRITICAL: Free Copper-64 >2.0% → accumulation in liver/kidneys, image degradation!
    Specific activity <10 GBq/μmol → reduced hypoxia contrast!

Usage:
  Copper64ATSMQualityChecker.exe                            → demo mode (console output)
  Copper64ATSMQualityChecker.exe input.csv output.json      → evaluate your data

Input format:
BatchNumber,RadionuclidicPurityPercent,RadiochemicalPurityPercent,FreeCopperPercent,ATSMLigandImpurityPercent,pH,EndotoxinsEU,SterilityTest,HeavyMetalsPPM,SpecificActivityGBqPerUmol

Example (sterility: 0=sterile, 1=contaminated):
  CU64-ATSM-2026-001,99.95,98.5,0.5,1.0,7.2,50.0,0,2,25.0

— WHY IS THIS NEEDED?
[64Cu]Cu-ATSM is a lipophilic copper-64 complex used in Positron Emission Tomography (PET) for tissue hypoxia imaging:
• Cu-64 Half-life: 12.7 hours — optimal for logistics and scanning
• Mechanism: Penetrates cells, reduced under hypoxic conditions, and trapped intracellularly
• Applications: Oncology (aggressive tumor detection), Cardiology (myocardial ischemia), Neurology

⚠️  CRITICAL:
• Radiochemical purity ≥95% — ensures signal comes from ATSM complex, not free copper
• Free Copper ≤2.0% — free Cu-64 is rapidly taken up by ceruloplasmin and accumulates in the liver, creating background noise and potential toxicity
• Specific activity ≥10 GBq/μmol — necessary to prevent saturation of transport mechanisms by cold metal
• pH 4.5–8.5 — physiological range for IV administration
• Endotoxins ≤175 EU/vial — safety standard for parenterals
• Sterility — MANDATORY

Key features:
• Control of specific impurity — free Copper-64
• Assessment of specific activity as a key efficacy parameter
• Radionuclidic purity check (exclusion of long-lived satellite isotopes)

Critical parameters:
• Radionuclidic purity: ≥99.9%
• Radiochemical purity: ≥95.0%
• Free Copper-64: ≤2.0%
• ATSM Ligand: ≤5.0%
• Specific activity: ≥10.0 GBq/μmol
• pH: 4.5–8.5
• Endotoxins: ≤175 EU/vial
• Sterility: no microbial growth
• Heavy metals: ≤10 ppm

💡 Usage tips:
1. Radiochemical purity determined by TLC or HPLC with radioactive detector
2. Free copper content controlled by TLC (solvent systems: acetonitrile/water or citrate buffer)
3. Specific activity calculated from total activity and molar amount of ligand (determined by HPLC-UV)
4. Due to 12.7h half-life, all measurements must be performed promptly

⚠️ Note: Cu-ATSM is a redox-sensitive indicator. Presence of reducers or oxidizers in the preparation can distort in vivo results. Control of ligand purity and absence of foreign metals is critical for complex stability.

input.csv

BatchNumber,RadionuclidicPurityPercent,RadiochemicalPurityPercent,FreeCopperPercent,ATSMLigandImpurityPercent,pH,EndotoxinsEU,SterilityTest,HeavyMetalsPPM,SpecificActivityGBqPerUmol
CU64-ATSM-2026-001,99.95,98.5,0.5,1.0,7.2,50.0,0,2,25.0

URS & FS — User Requirements and Functional Specification

This document describes the controlled interface and behaviour of Copper64ATSMQualityChecker for Copper-64 ATSM.

Domain limits and critical parameters

Key fragments from the source description are shown below. Before production use, limits must be verified against the approved specification, registration dossier and local SOPs.
  • ℹ️ Utility checks critical parameters of [64Cu]Cu-ATSM:
  • • Radionuclidic purity (≥99.9%)
  • • Radiochemical purity (≥95%)
  • • Free Copper-64 impurity (≤2.0%)
  • • ATSM Ligand impurity (≤5.0%)
  • • Specific activity (≥10 GBq/μmol)
  • • pH, endotoxins, sterility, heavy metals
  • ⚠️ CRITICAL: Free Copper-64 >2.0% → accumulation in liver/kidneys, image degradation!
  • BatchNumber,RadionuclidicPurityPercent,RadiochemicalPurityPercent,FreeCopperPercent,ATSMLigandImpurityPercent,pH,EndotoxinsEU,SterilityTest,HeavyMetalsPPM,SpecificActivityGBqPerUmol
  • Example (sterility: 0=sterile, 1=contaminated):
  • ⚠️ CRITICAL:
  • • Radiochemical purity ≥95% — ensures signal comes from ATSM complex, not free copper
  • • Free Copper ≤2.0% — free Cu-64 is rapidly taken up by ceruloplasmin and accumulates in the liver, creating background noise and potential toxicity
  • • Specific activity ≥10 GBq/μmol — necessary to prevent saturation of transport mechanisms by cold metal

URS — User Requirements Specification

IDRequirementCriticalityAcceptance criterion
URS-001The utility shall accept an input.csv file with the exact headers defined in the data contract.HighThe file is processed without manual header editing.
URS-002The utility shall perform deterministic QC evaluation for Copper-64 ATSM using input values, approved limits and domain rules.HighEach input row receives a PASS / WARNING / FAIL status.
URS-003The utility shall validate mandatory fields, data types, numeric ranges, units and pharmaceutical/radiochemical plausibility.HighSchema and conversion errors are explicitly reported.
URS-004The utility shall identify critical deviations related to radionuclidic purity, radiochemical purity, free radionuclide, impurities, pH, endotoxins and sterility when such fields are present.HighA critical deviation causes FAIL or a separate critical finding.
URS-005The utility shall generate output.json with machine-readable results, source values, warnings and failures.HighJSON is suitable for LIMS/ELN/MES integration and QA/QC review.
URS-006The utility shall not use machine learning to decide conformance.MediumThe result is based on explicit rules, thresholds and input values.
URS-007The utility shall preserve traceability between batch number, input values, applied rules and final status.HighThe output contains the batch identifier and the list of checked parameters.
URS-008The documentation shall support IQ/OQ preparation and inspection discussion with FDA/EMA/Roszdravnadzor or local regulators.MediumURS & FS, input.csv/output.json contract and test scenarios are supplied with the utility.

input.csv contract

#FieldTypeSamplePurpose
1BatchNumberstringCU64-ATSM-2026-001Batch or lot identifier used for traceability.
2RadionuclidicPurityPercentstring99.95Radionuclidic purity; a critical radiation-safety and impurity parameter.
3RadiochemicalPurityPercentstring98.5Radiochemical purity; confirms the labelled chemical form and binding quality.
4FreeCopperPercentdecimal0.5Free radionuclide / unbound species; important for non-target uptake and toxicity.
5ATSMLigandImpurityPercentstring1.0Controlled impurity or residual material.
6pHdecimal7.2Solution pH; relevant for stability, compatibility and administration.
7EndotoxinsEUdecimal50.0Bacterial endotoxins; critical for parenteral administration.
8SterilityTestflag / boolean0Sterility result; critical release parameter.
9HeavyMetalsPPMdecimal2Elemental impurity / metal residue parameter.
10SpecificActivityGBqPerUmoldecimal25.0Radioactivity value used for release, decay or dose-related assessment.
BatchNumber,RadionuclidicPurityPercent,RadiochemicalPurityPercent,FreeCopperPercent,ATSMLigandImpurityPercent,pH,EndotoxinsEU,SterilityTest,HeavyMetalsPPM,SpecificActivityGBqPerUmol
CU64-ATSM-2026-001,99.95,98.5,0.5,1.0,7.2,50.0,0,2,25.0

FS — Functional Specification

IDFunctionImplementation
FS-001CSV importRead input.csv in UTF-8/CSV-compatible format and validate the header and expected columns.
FS-002Schema validationCheck mandatory fields and column count; report unknown or missing key fields.
FS-003Type conversionConvert numeric, flag and text values; invalid formats are recorded as row-level errors.
FS-004Domain rule engineApply domain rules for Copper-64 ATSM, including critical limits from the utility description and approved specification.
FS-005Status aggregationProduce final status: FAIL for critical failure, WARNING for non-critical deviation, PASS for conformance.
FS-006JSON exportWrite output.json with detailed checks, source values, warnings, failures and critical findings.
FS-007Audit supportKeep the result structure suitable for review, deviation investigation, calculation reproduction and IQ/OQ preparation.
FS-008Integration contractSupport the production scenario: LIMS/ELN/MES creates input.csv, the utility returns output.json, the portal displays description and documentation.

Example output.json

{
  "utilityId": "copper64-atsm-quality-checker",
  "api": "Copper-64 ATSM",
  "overallStatus": "PASS|WARNING|FAIL",
  "sourceFile": "input.csv",
  "checks": [
    {
      "parameter": "BatchNumber",
      "value": "CU64-ATSM-2026-001",
      "status": "PASS|WARNING|FAIL",
      "message": "Rule-based check result"
    },
    {
      "parameter": "RadionuclidicPurityPercent",
      "value": "99.95",
      "status": "PASS|WARNING|FAIL",
      "message": "Rule-based check result"
    },
    {
      "parameter": "RadiochemicalPurityPercent",
      "value": "98.5",
      "status": "PASS|WARNING|FAIL",
      "message": "Rule-based check result"
    },
    {
      "parameter": "FreeCopperPercent",
      "value": "0.5",
      "status": "PASS|WARNING|FAIL",
      "message": "Rule-based check result"
    },
    {
      "parameter": "ATSMLigandImpurityPercent",
      "value": "1.0",
      "status": "PASS|WARNING|FAIL",
      "message": "Rule-based check result"
    },
    {
      "parameter": "pH",
      "value": "7.2",
      "status": "PASS|WARNING|FAIL",
      "message": "Rule-based check result"
    },
    {
      "parameter": "EndotoxinsEU",
      "value": "50.0",
      "status": "PASS|WARNING|FAIL",
      "message": "Rule-based check result"
    },
    {
      "parameter": "SterilityTest",
      "value": "0",
      "status": "PASS|WARNING|FAIL",
      "message": "Rule-based check result"
    }
  ],
  "criticalFindings": []
}

OQ/PQ test scenarios

IDScenarioExpected result
OQ-001Valid sample rowPASS or acceptable WARNING according to the rules.
OQ-002Mandatory column missingSchema error or FAIL.
OQ-003Non-numeric value in numeric fieldType-conversion error.
OQ-004Critical parameter outside limitFAIL and critical finding.
PQ-001User real batch/lotReviewed result with input.csv and output.json retained.

QA/QC and change control

  • Do not rename columns without updating the validator and test set.
  • Retain input.csv, output.json, executable version and checksum.
  • Before production use, perform IQ/OQ/PQ or equivalent CSV/CSA verification.
  • Critical radiopharmaceutical limits must be verified against the approved specification and local SOPs.

Included in packages

Cardiology QC Suite

QC package for cardiology medicines: antihypertensives, anticoagulants, antiplatelets, lipid-lowering and antiarrhythmic medicines plus supporting QC checks.

Open

Gastroenterology QC Suite

QC package for gastroenterology: PPIs, antiemetics, prokinetics, IBD medicines, laxatives, enzymes and GI anti-infectives.

Open

Neurology QC Suite

QC package for neurology and neuropsychiatry: antiepileptics, antiparkinsonian medicines, antidepressants, antipsychotics, analgesics and neurological diagnostic radiopharmaceuticals.

Open

PetRad3: expanded PET/SPECT and radiopharmaceutical QC package

A curated suite for PET/SPECT radiopharmaceuticals, generator and cyclotron radionuclides, labelled compounds, radiochemical purity, breakthrough, sterility and endotoxin control.

Open

Radiology QC Suite

QC package for radiology and diagnostic imaging: radiopharmaceuticals, PET/SPECT, contrast media, iodinated and gadolinium products, plus particle, sterility and endotoxin checks.

Open

RPH isotope family: long-lived PET / immuno-PET

Cu-64, Zr-89, I-124, Mn-52 and Y-86 for antibodies, slow kinetics and extended imaging.

Open

RPH organ/system: brain and CNS

Brain perfusion, dopamine transporter, amyloid/tau, receptor imaging and neurological SPECT/PET.

Open

RPH organ/system: cardiovascular

Myocardial perfusion, cardiac PET/SPECT, ventricular function, blood-pool and perfusion tracers.

Open

RPH organ/system: hepatobiliary and GI

HIDA, mebrofenin, gallbladder, gastric emptying, GI transit, bleeding and liver/spleen imaging.

Open

RPH organ/system: oncology and theranostics

Tumour imaging, PSMA/FAPI/receptor tracers, immuno-PET, targeted radionuclide therapy and radioembolization.

Open

RPH organ/system: renal and urinary

Renography, GFR/ERPF, renal uptake, DMSA/MAG3/DTPA and bladder-related workflows.

Open

RPH use case: PET/SPECT oncology diagnostics and receptor imaging

F-18, Ga-68, Cu-64, Zr-89, In-111 and other diagnostic tracers: synthesis, purity, receptor targeting, immuno-PET and generator-based workflows.

Open

RPH workflow: generators and isotope purity

Generator eluate, breakthrough, radionuclidic purity, isotope mix and starting radionuclides.

Open

RPH workflow: imaging QC and quantitative interpretation

Acquisition, uptake, clearance, perfusion, transit, ejection fraction, segmentation and quantitative imaging.

Open

RPH workflow: instruments, devices and radiation safety

PET/gamma-camera state, calibration, detector QC, energy window, TOF, shielding and radiation safety.

Open

RPH workflow: product release QC

Assay, purity, sterility, endotoxins, pH, impurities, appearance and batch-release checks.

Open

RPH workflow: stability, storage, decay and waste

Kinetic stability, shelf life, decay correction, expiry, storage, trend and radioactive waste.

Open

RPH: combined radiopharmaceutical QC package

RPH combines PetRad, PetRad2 and PetRad3 into one umbrella package for PET/SPECT, therapeutic radionuclides, generators, labelled compounds, decay calculations, sterility, endotoxins and radiochemical/radionuclidic purity.

Open

Urology QC Suite

QC package for urology: BPH, urolithiasis, overactive bladder, urinary-tract infection medicines and supporting antimicrobial QC checks.

Open