Cobalt58QualityChecker
Cobalt58
Utility description: Cobalt58
Cobalt58 Quality Checker — radiopharmaceutical QC utility. Limited source description was provided. The utility shall read input.csv, validate declared fields, apply deterministic acceptance rules defined in the executable and produce output.json for QA/QC review.
input.csv
id,val
URS & FS — User Requirements and Functional Specification
This document describes the controlled interface and behaviour of Cobalt58QualityChecker for Cobalt58.
Domain limits and critical parameters
- Critical limits must be defined in the approved specification and implemented in the executable.
URS — User Requirements Specification
| ID | Requirement | Criticality | Acceptance criterion |
|---|---|---|---|
| URS-001 | The utility shall accept an input.csv file with the exact headers defined in the data contract. | High | The file is processed without manual header editing. |
| URS-002 | The utility shall perform deterministic QC evaluation for Cobalt58 using input values, approved limits and domain rules. | High | Each input row receives a PASS / WARNING / FAIL status. |
| URS-003 | The utility shall validate mandatory fields, data types, numeric ranges, units and pharmaceutical/radiochemical plausibility. | High | Schema and conversion errors are explicitly reported. |
| URS-004 | The utility shall identify critical deviations related to radionuclidic purity, radiochemical purity, free radionuclide, impurities, pH, endotoxins and sterility when such fields are present. | High | A critical deviation causes FAIL or a separate critical finding. |
| URS-005 | The utility shall generate output.json with machine-readable results, source values, warnings and failures. | High | JSON is suitable for LIMS/ELN/MES integration and QA/QC review. |
| URS-006 | The utility shall not use machine learning to decide conformance. | Medium | The result is based on explicit rules, thresholds and input values. |
| URS-007 | The utility shall preserve traceability between batch number, input values, applied rules and final status. | High | The output contains the batch identifier and the list of checked parameters. |
| URS-008 | The documentation shall support IQ/OQ preparation and inspection discussion with FDA/EMA/Roszdravnadzor or local regulators. | Medium | URS & FS, input.csv/output.json contract and test scenarios are supplied with the utility. |
input.csv contract
| # | Field | Type | Sample | Purpose |
|---|---|---|---|---|
| 1 | id | string | | Controlled input parameter used by the deterministic QC rules. |
| 2 | val | string / decimal | | Controlled input parameter used by the deterministic QC rules. |
id,val
FS — Functional Specification
| ID | Function | Implementation |
|---|---|---|
| FS-001 | CSV import | Read input.csv in UTF-8/CSV-compatible format and validate the header and expected columns. |
| FS-002 | Schema validation | Check mandatory fields and column count; report unknown or missing key fields. |
| FS-003 | Type conversion | Convert numeric, flag and text values; invalid formats are recorded as row-level errors. |
| FS-004 | Domain rule engine | Apply domain rules for Cobalt58, including critical limits from the utility description and approved specification. |
| FS-005 | Status aggregation | Produce final status: FAIL for critical failure, WARNING for non-critical deviation, PASS for conformance. |
| FS-006 | JSON export | Write output.json with detailed checks, source values, warnings, failures and critical findings. |
| FS-007 | Audit support | Keep the result structure suitable for review, deviation investigation, calculation reproduction and IQ/OQ preparation. |
| FS-008 | Integration contract | Support the production scenario: LIMS/ELN/MES creates input.csv, the utility returns output.json, the portal displays description and documentation. |
Example output.json
{
"utilityId": "cobalt58-quality-checker",
"api": "Cobalt58",
"overallStatus": "PASS|WARNING|FAIL",
"sourceFile": "input.csv",
"checks": [
{
"parameter": "id",
"value": "",
"status": "PASS|WARNING|FAIL",
"message": "Rule-based check result"
},
{
"parameter": "val",
"value": "",
"status": "PASS|WARNING|FAIL",
"message": "Rule-based check result"
}
],
"criticalFindings": []
}
OQ/PQ test scenarios
| ID | Scenario | Expected result |
|---|---|---|
| OQ-001 | Valid sample row | PASS or acceptable WARNING according to the rules. |
| OQ-002 | Mandatory column missing | Schema error or FAIL. |
| OQ-003 | Non-numeric value in numeric field | Type-conversion error. |
| OQ-004 | Critical parameter outside limit | FAIL and critical finding. |
| PQ-001 | User real batch/lot | Reviewed result with input.csv and output.json retained. |
QA/QC and change control
- Do not rename columns without updating the validator and test set.
- Retain
input.csv,output.json, executable version and checksum. - Before production use, perform IQ/OQ/PQ or equivalent CSV/CSA verification.
- Critical radiopharmaceutical limits must be verified against the approved specification and local SOPs.
Included in packages
PetRad3: expanded PET/SPECT and radiopharmaceutical QC package
A curated suite for PET/SPECT radiopharmaceuticals, generator and cyclotron radionuclides, labelled compounds, radiochemical purity, breakthrough, sterility and endotoxin control.
OpenRadiology QC Suite
QC package for radiology and diagnostic imaging: radiopharmaceuticals, PET/SPECT, contrast media, iodinated and gadolinium products, plus particle, sterility and endotoxin checks.
OpenRPH use case: generators, isotope purity and starting radionuclides
Control of generator eluate, breakthrough, radionuclidic purity, isotope mix, carrier/free radionuclides and starting radionuclides before labeling.
OpenRPH workflow: generators and isotope purity
Generator eluate, breakthrough, radionuclidic purity, isotope mix and starting radionuclides.
OpenRPH workflow: product release QC
Assay, purity, sterility, endotoxins, pH, impurities, appearance and batch-release checks.
OpenRPH: combined radiopharmaceutical QC package
RPH combines PetRad, PetRad2 and PetRad3 into one umbrella package for PET/SPECT, therapeutic radionuclides, generators, labelled compounds, decay calculations, sterility, endotoxins and radiochemical/radionuclidic purity.
Open