UlipristalAcetateQualityChecker
Ulipristal Acetate
Ulipristal Acetate Quality Checker — Ulipristal Acetate (Selective Progesterone Receptor Modulator) (Ph. Eur. draft, EMA)
ℹ️ The utility checks assay, specific rotation, melting point (with decomposition), UV ratio, critical impurities (ulipristal — hydrolysis product of acetate, epimer), loss on drying, heavy metals, residual solvents.
ℹ️ Does not use machine learning — rule-based logic only.
⚠️ CRITICAL: Ulipristal (≤0.5%) — hydrolysis product of acetate group! Moisture control (≤0.5%) mandatory! Ulipristal acetate has EMA restrictions due to liver injury risk (for fibroid treatment). Substance quality critical for safety!
Usage:
UlipristalAcetateQualityChecker.exe → demo mode (console output)
UlipristalAcetateQualityChecker.exe input.csv output.json → evaluate your data
Input format:
BatchNumber,AssayPercent,SpecificRotation,MeltingPoint,UV240_280Ratio,ImpurityUlipristal,ImpurityEpimer,TotalImpurities,LossOnDrying,HeavyMetals,ResidualSolvents,EthanolPPM,AcetonePPM,ClarityNTU,ColorAPHA
Example:
UPA-2026-001,99.5,110.0,182.5,2.0,0.2,0.1,0.4,0.3,5,1500,800,500,2,30
— WHY IS THIS NEEDED?
Ulipristal acetate — selective progesterone receptor modulator (SPRM):
• Emergency contraception (Ella, EllaOne — up to 120 hours after unprotected intercourse)
• Treatment of uterine fibroid symptoms (Esmya — with EMA restrictions due to liver injury risk)
⚠️ CRITICAL:
• Specific rotation +105.0° to +115.0° — key identification parameter (in methanol)
• Melting point 180.0–185.0°C (with decomposition) — confirms structure and purity
• UV ratio A240/A280: 1.8–2.2 — confirms structure (maximum at 240 nm)
• Ulipristal ≤0.5% — HYDROLYSIS PRODUCT OF ACETATE GROUP! Forms on moisture contact, reduces activity and alters pharmacokinetics
• Epimer ≤0.5% — STEREOISOMER! Affects receptor binding and safety
• Total impurities ≤1.0% — critical due to narrow therapeutic window and liver injury risk
⚠️ Special attention: Ulipristal acetate is EXTREMELY sensitive to moisture and hydrolysis! Requires storage in airtight, moisture-protected packaging at temperature not exceeding 25°C. Analysis must be performed under humidity-controlled conditions! Ulipristal impurity (free alcohol) is especially critical — even minor amounts indicate degradation and disrupt action profile. Loss on drying control (≤0.5%) is mandatory. In 2020, EMA suspended ulipristal acetate for fibroid treatment due to serious liver injury risk — substance quality is critical for risk minimization!
Critical parameters:
• Assay: 97.0–103.0% (on dried basis)
• Specific rotation: +105.0° to +115.0° (in methanol)
• Melting point: 180.0–185.0°C (with decomposition)
• UV ratio A240/A280: 1.8–2.2
• Ulipristal (hydrolysis): ≤0.5% (HYDROLYSIS PRODUCT OF ACETATE!)
• Epimer: ≤0.5% (STEREOISOMER!)
• Total impurities: ≤1.0%
• Loss on drying: ≤0.5% (MOISTURE CONTROL CRITICAL!)
• Heavy metals: ≤10 ppm
• Residual solvents: ≤5000 ppm (total), ethanol ≤5000 ppm, acetone ≤5000 ppm
• Clarity of 0.1% solution in methanol: ≤5 NTU
• Color of 0.1% solution in methanol: ≤50 APHA
⚠️ Note: This utility is for SUBSTANCE (active pharmaceutical ingredient), not finished tablets! Quality control of substance is the first and most important step in production. Only pure substance guarantees correct SPRM action profile and minimizes patient risks. Given EMA restrictions, ulipristal acetate substance quality has special significance for safety.
input.csv
BatchNumber,AssayPercent,SpecificRotation,MeltingPoint,UV240_280Ratio,ImpurityUlipristal,ImpurityEpimer,TotalImpurities,LossOnDrying,HeavyMetals,ResidualSolvents,EthanolPPM,AcetonePPM,ClarityNTU,ColorAPHA UPA-2026-001,99.5,110.0,182.5,2.0,0.2,0.1,0.4,0.3,5,1500,800,500,2,30
URS & FS — user requirements and functional specification
This document defines user requirements and functional specification for the quality-control utility. It supports deployment discussion, IQ/OQ preparation and QC workflow integration.
1. Scope
The Ulipristal Acetate Quality Checker utility is used for Ulipristal Acetate. The actual input.csv is the source of truth for the input structure; control criteria are defined by the executable and the domain description.
The utility does not use machine learning; decisions are produced by deterministic rules.
Categories: Contraceptives
Tags: assay, contraceptives, fixed-dose combinations, heavy metals, hormones, impurities, residual solvents, solid dosage
2. Execution modes
UlipristalAcetateQualityChecker.exe → demo mode (console output) UlipristalAcetateQualityChecker.exe input.csv output.json → evaluate your data
3. Key controlled areas
- assay / content
- purity and impurities
- residual solvents
- heavy metals / elemental impurities
- pH and physicochemical parameters
4. Domain limits and critical parameters
- ⚠️ CRITICAL: Ulipristal (≤0.5%) — hydrolysis product of acetate group! Moisture control (≤0.5%) mandatory! Ulipristal acetate has EMA restrictions due to liver injury risk (for fibroid treatment). Substance quality critical for safety!
- ⚠️ CRITICAL:
- Specific rotation +105.0° to +115.0° — key identification parameter (in methanol)
- Melting point 180.0–185.0°C (with decomposition) — confirms structure and purity
- UV ratio A240/A280: 1.8–2.2 — confirms structure (maximum at 240 nm)
- Ulipristal ≤0.5% — HYDROLYSIS PRODUCT OF ACETATE GROUP! Forms on moisture contact, reduces activity and alters pharmacokinetics
- Epimer ≤0.5% — STEREOISOMER! Affects receptor binding and safety
- Total impurities ≤1.0% — critical due to narrow therapeutic window and liver injury risk
- ⚠️ Special attention: Ulipristal acetate is EXTREMELY sensitive to moisture and hydrolysis! Requires storage in airtight, moisture-protected packaging at temperature not exceeding 25°C. Analysis must be performed under humidity-controlled conditions! Ulipristal impurity (free alcohol) is especially critical — even minor amounts indicate degradation and disrupt action profile. Loss on drying control (≤0.5%) is mandatory. In 2020, EMA suspended ulipristal acetate for fibroid treatment due to serious liver injury risk — substance quality is critical for risk minimization!
- Critical parameters:
- Assay: 97.0–103.0% (on dried basis)
- Specific rotation: +105.0° to +115.0° (in methanol)
- Melting point: 180.0–185.0°C (with decomposition)
- UV ratio A240/A280: 1.8–2.2
- Ulipristal (hydrolysis): ≤0.5% (HYDROLYSIS PRODUCT OF ACETATE!)
- Epimer: ≤0.5% (STEREOISOMER!)
- Total impurities: ≤1.0%
- Loss on drying: ≤0.5% (MOISTURE CONTROL CRITICAL!)
- Heavy metals: ≤10 ppm
- Residual solvents: ≤5000 ppm (total), ethanol ≤5000 ppm, acetone ≤5000 ppm
- Clarity of 0.1% solution in methanol: ≤5 NTU
- Color of 0.1% solution in methanol: ≤50 APHA
- ⚠️ Note: This utility is for SUBSTANCE (active pharmaceutical ingredient), not finished tablets! Quality control of substance is the first and most important step in production. Only pure substance guarantees correct SPRM action profile and minimizes patient risks. Given EMA restrictions, ulipristal acetate substance quality has special significance for safety.
5. URS — user requirements
| ID | Requirement | Criticality | Acceptance criterion |
|---|---|---|---|
| URS-001 | The system shall accept an input.csv file for Ulipristal Acetate with the exact columns listed in the “Input data contract” section. | High | A file with the correct header is processed without manual editing; missing mandatory columns produce FAIL/import error. |
| URS-002 | The system shall support execution without arguments in demo mode and execution with input.csv output.json for user data. | Medium | Both execution scenarios produce a predictable result or clear diagnostic error. |
| URS-003 | The system shall perform rule-based controls for: assay / content, purity and impurities, residual solvents, heavy metals / elemental impurities, pH and physicochemical parameters. | High | Each controlled parameter receives a status and message; the result does not depend on hidden Excel formulas or ML. |
| URS-004 | The system shall preserve traceability between batch/lot, source values, applied rules and final verdict. | High | Output includes batch identifier, source values, parameter statuses and critical findings. |
| URS-005 | The system shall generate machine-readable output.json for LIMS/ELN/MES, batch record and QA/QC review. | High | JSON contains overall status, check array, warnings, failures and source-file reference. |
| URS-006 | The system shall support use in the client validation package: URS/FS, IQ/OQ preparation, installation and operational scenario checks. | High | The document, test scenarios and reproducible CSV/JSON flow are suitable for audit and internal approval. |
| URS-007 | The system shall clearly separate technical data errors from specification nonconformities. | Medium | Schema/type errors are not mixed with pharmacopoeial deviations and are reported separately. |
6. input.csv data contract
The source of truth for the input schema is the actual input.csv header. Column names are technical identifiers and are not translated.
| # | Column | Type | Unit | Description | Sample | Control rule |
|---|---|---|---|---|---|---|
| 1 | BatchNumber | identifier | as specified | Batch Number | UPA-2026-001 | mandatory field; used for batch/lot traceability |
| 2 | AssayPercent | decimal | % | Assay % | 99.5 | numeric value; compared with assay/purity limit from specification or method |
| 3 | SpecificRotation | decimal | as specified | Specific Rotation | 110.0 | mandatory numeric value; rule comparison is performed by the utility |
| 4 | MeltingPoint | decimal | °C | Melting Point | 182.5 | mandatory numeric value; rule comparison is performed by the utility |
| 5 | UV240_280Ratio | decimal | as specified | UV240 280 Ratio | 2.0 | mandatory numeric value; rule comparison is performed by the utility |
| 6 | ImpurityUlipristal | decimal | as specified | Impurity Ulipristal | 0.2 | numeric value; compared with individual or total impurity limit |
| 7 | ImpurityEpimer | decimal | as specified | Impurity Epimer | 0.1 | numeric value; compared with individual or total impurity limit |
| 8 | TotalImpurities | decimal | as specified | Total Impurities | 0.4 | mandatory numeric value; rule comparison is performed by the utility |
| 9 | LossOnDrying | decimal | as specified | Loss On Drying | 0.3 | mandatory numeric value; rule comparison is performed by the utility |
| 10 | HeavyMetals | decimal | as specified | Heavy Metals | 5 | numeric value; checked as elemental/metal impurity |
| 11 | ResidualSolvents | decimal | as specified | Residual Solvents | 1500 | numeric value; checked as residual solvent against the applicable limit |
| 12 | EthanolPPM | decimal | ppm | Ethanol PPM | 800 | numeric value; checked as residual solvent against the applicable limit |
| 13 | AcetonePPM | decimal | ppm | Acetone PPM | 500 | numeric value; checked as residual solvent against the applicable limit |
| 14 | ClarityNTU | decimal | as specified | Clarity NTU | 2 | mandatory numeric value; rule comparison is performed by the utility |
| 15 | ColorAPHA | decimal | as specified | Color APHA | 30 | mandatory numeric value; rule comparison is performed by the utility |
CSV example
BatchNumber,AssayPercent,SpecificRotation,MeltingPoint,UV240_280Ratio,ImpurityUlipristal,ImpurityEpimer,TotalImpurities,LossOnDrying,HeavyMetals,ResidualSolvents,EthanolPPM,AcetonePPM,ClarityNTU,ColorAPHA UPA-2026-001,99.5,110.0,182.5,2.0,0.2,0.1,0.4,0.3,5,1500,800,500,2,30
7. FS — functional specification
| ID | Function | Implementation description |
|---|---|---|
| FS-001 | CLI entry point | The executable UlipristalAcetateQualityChecker.exe supports demo mode and input.csv output.json processing mode. |
| FS-002 | CSV parser | The import module reads CSV, validates header, column presence/order, value count and encoding. Decimal values are expected with a dot separator. |
| FS-003 | Field conversion | Each column is converted to the expected type: identifier, text, decimal number, date/time or boolean flag. |
| FS-004 | Domain rule engine | For Ulipristal Acetate, explicit rules are applied: range, minimum, maximum, absence of prohibited flag, data completeness or calculation-based check. |
| FS-005 | Criticality handling | Critical violations produce FAIL; non-critical deviations and incomplete data produce WARNING; full conformance produces PASS. |
| FS-006 | JSON writer | output.json stores overall status, per-parameter results, source values, warnings, failures and diagnostic messages. |
| FS-007 | Integration contract | The CSV → JSON format is stable for invocation from LIMS/ELN/MES, scheduled task or wrapper service. |
| FS-008 | Error handling | Schema error, missing file, non-numeric value or JSON write failure returns diagnosable error without silent PASS. |
8. output.json contract
The output file must be suitable for automated processing, audit review and correlation with the source input.csv row.
{
"utility": "UlipristalAcetateQualityChecker",
"api": "Ulipristal Acetate",
"batchNumber": "UPA-2026-001",
"overallStatus": "PASS|WARNING|FAIL",
"checkedAtUtc": "2026-05-18T00:00:00Z",
"checks": [
{
"parameter": "BatchNumber",
"value": "UPA-2026-001",
"unit": "as specified",
"status": "PASS|WARNING|FAIL",
"message": "Rule-based check result"
},
{
"parameter": "AssayPercent",
"value": "99.5",
"unit": "%",
"status": "PASS|WARNING|FAIL",
"message": "Rule-based check result"
},
{
"parameter": "SpecificRotation",
"value": "110.0",
"unit": "as specified",
"status": "PASS|WARNING|FAIL",
"message": "Rule-based check result"
},
{
"parameter": "MeltingPoint",
"value": "182.5",
"unit": "°C",
"status": "PASS|WARNING|FAIL",
"message": "Rule-based check result"
},
{
"parameter": "UV240_280Ratio",
"value": "2.0",
"unit": "as specified",
"status": "PASS|WARNING|FAIL",
"message": "Rule-based check result"
},
{
"parameter": "ImpurityUlipristal",
"value": "0.2",
"unit": "as specified",
"status": "PASS|WARNING|FAIL",
"message": "Rule-based check result"
},
{
"parameter": "ImpurityEpimer",
"value": "0.1",
"unit": "as specified",
"status": "PASS|WARNING|FAIL",
"message": "Rule-based check result"
},
{
"parameter": "TotalImpurities",
"value": "0.4",
"unit": "as specified",
"status": "PASS|WARNING|FAIL",
"message": "Rule-based check result"
}
],
"criticalFindings": [],
"sourceFile": "input.csv"
}9. OQ/PQ test scenarios
| ID | Scenario | Expected result |
|---|---|---|
| TC-001 | Valid CSV with expected header and sample row | All rows are processed; output contains PASS/WARNING/FAIL and parameter-level detail. |
| TC-002 | A mandatory input.csv column is missing | Import is rejected or the row receives FAIL with schema reference. |
| TC-003 | A numeric field contains text or a blank value | Type conversion error is recorded; the result is not hidden as PASS. |
| TC-004 | A parameter is outside specification or critical limit | Critical parameters produce FAIL; non-critical deviations produce WARNING according to the rule. |
| TC-007 | Residual solvent above applicable limit | FAIL is produced with solvent name and measured value. |
10. QA/QC, CSV and change control
- Before production use, the client records executable version, checksum, specification/monograph version, test CSV, expected JSON and IQ/OQ results.
- Column names must not be changed without updating the validator and test scenarios.
- The source CSV, output.json and utility version should be stored together as an evidence package.
- Any change in control rules must go through change control and repeated OQ scenario verification.
Included in packages
Contraceptives QC Suite
Quality-control package for contraceptives: hormonal APIs, fixed combinations, implants, rings and intrauterine systems.
OpenEndocrinology QC Suite
QC package for endocrinology: thyroid, pituitary/peptide hormones, corticosteroids, sex hormones and selected metabolic medicines.
OpenGynecology QC Suite
QC package for gynecology: hormones, contraceptives, uterotonics, anti-infectives and women’s-health medicines.
Open