Nonoxynol9QualityChecker
Nonoxynol9
Nonoxynol-9 Quality Checker — Nonoxynol-9 (Spermicidal Surfactant) (Ph. Eur. 2.8.1)
ℹ️ The utility checks assay, critical impurities (nonylphenol, 1,4-dioxane, ethylene/propylene oxide), physicochemical parameters (hydroxyl/acid value, peroxide value, refractive index, density).
ℹ️ Does not use machine learning — rule-based logic only.
⚠️ CRITICAL: Nonylphenol (≤0.1%) — ENDORINE DISRUPTOR! 1,4-Dioxane (≤10 ppm) — CARCINOGEN! Peroxide value (≤5.0) — oxidation control! Nonoxynol-9 NOT recommended for rectal use (HIV risk)!
Usage:
Nonoxynol9QualityChecker.exe → demo mode (console output)
Nonoxynol9QualityChecker.exe input.csv output.json → evaluate your data
Input format:
BatchNumber,AssayPercent,NonylphenolPercent,DioxanePPM,EthyleneOxidePPM,PropyleneOxidePPM,HeavyMetalsPPM,LossOnDryingPercent,SulfatedAshPercent,HydroxylValue,AcidValue,PeroxideValue,RefractiveIndex,DensityGPerMl,ColorAPHA,EthanolPPM,AcetonePPM
Example:
NO9-2026-001,99.5,0.05,5,0.5,0.3,10,0.5,0.05,58.0,0.8,3.0,1.490,1.060,50,800,500
— WHY IS THIS NEEDED?
Nonoxynol-9 — nonionic surfactant used as spermicide in:
• Vaginal gels, creams, films (Emko, Pharmatex)
• Condoms with spermicidal lubricant
• Diaphragms and caps with application
⚠️ CRITICAL:
• Nonylphenol ≤0.1% — ENDORINE DISRUPTOR! Disrupts hormonal balance, toxic to reproductive system. Mandatory control!
• 1,4-Dioxane ≤10 ppm — CARCINOGEN group 2A (IARC)! Forms during ethoxylation. Strict limit!
• Ethylene oxide/propylene oxide ≤1 ppm — residual monomers, potential carcinogens
• Peroxide value ≤5.0 mmol/kg — nonoxynol-9 oxidation-sensitive! High value = reduced spermicidal activity + toxic products
• Hydroxyl value 50–65 mg KOH/g — confirms degree of ethoxylation (~9)
⚠️ Special attention: WHO and FDA DO NOT recommend nonoxynol-9 for rectal use! Damages rectal mucosa, increases HIV infection risk 2–5 times. Use only for vaginal contraception with informed consent.
Critical parameters:
• Assay: 98.0–102.0%
• Nonylphenol: ≤0.1% (ENDOCRINE DISRUPTOR!)
• 1,4-Dioxane: ≤10 ppm (CARCINOGEN!)
• Ethylene oxide: ≤1 ppm
• Propylene oxide: ≤1 ppm
• Heavy metals: ≤20 ppm
• Loss on drying: ≤1.0%
• Sulfated ash: ≤0.1%
• Hydroxyl value: 50–65 mg KOH/g
• Acid value: ≤1.0 mg KOH/g
• Peroxide value: ≤5.0 mmol/kg (oxidation control!)
• Refractive index: 1.485–1.495
• Density (25°C): 1.050–1.070 g/mL
• Color: ≤100 APHA
• Residual solvents: ethanol ≤5000 ppm, acetone ≤5000 ppm
⚠️ Note: Nonoxynol-9 is a MIXTURE of polyethylene glycol ethers of nonylphenol with average ethoxylation degree 9. Assay determined as sum of HPLC peaks. Impurity control critical for safety! Store in tightly closed container, protected from light and moisture. Analyze quickly — oxidation-sensitive.
input.csv
BatchNumber,AssayPercent,NonylphenolPercent,DioxanePPM,EthyleneOxidePPM,PropyleneOxidePPM,HeavyMetalsPPM,LossOnDryingPercent,SulfatedAshPercent,HydroxylValue,AcidValue,PeroxideValue,RefractiveIndex,DensityGPerMl,ColorAPHA,EthanolPPM,AcetonePPM NO9-2026-001,99.5,0.05,5,0.5,0.3,10,0.5,0.05,58.0,0.8,3.0,1.490,1.060,50,800,500
URS & FS — user requirements and functional specification
This document defines user requirements and functional specification for the quality-control utility. It supports deployment discussion, IQ/OQ preparation and QC workflow integration.
1. Scope
The Nonoxynol9 Quality Checker utility is used for Nonoxynol9. The actual input.csv is the source of truth for the input structure; control criteria are defined by the executable and the domain description.
The utility does not use machine learning; decisions are produced by deterministic rules.
Categories: Contraceptives
Tags: assay, contraceptives, fixed-dose combinations, heavy metals, hormones, impurities, residual solvents
2. Execution modes
Nonoxynol9QualityChecker.exe → demo mode (console output) Nonoxynol9QualityChecker.exe input.csv output.json → evaluate your data
3. Key controlled areas
- assay / content
- residual solvents
- heavy metals / elemental impurities
- pH and physicochemical parameters
4. Domain limits and critical parameters
- ⚠️ CRITICAL: Nonylphenol (≤0.1%) — ENDORINE DISRUPTOR! 1,4-Dioxane (≤10 ppm) — CARCINOGEN! Peroxide value (≤5.0) — oxidation control! Nonoxynol-9 NOT recommended for rectal use (HIV risk)!
- ⚠️ CRITICAL:
- Nonylphenol ≤0.1% — ENDORINE DISRUPTOR! Disrupts hormonal balance, toxic to reproductive system. Mandatory control!
- 1,4-Dioxane ≤10 ppm — CARCINOGEN group 2A (IARC)! Forms during ethoxylation. Strict limit!
- Ethylene oxide/propylene oxide ≤1 ppm — residual monomers, potential carcinogens
- Peroxide value ≤5.0 mmol/kg — nonoxynol-9 oxidation-sensitive! High value = reduced spermicidal activity + toxic products
- Hydroxyl value 50–65 mg KOH/g — confirms degree of ethoxylation (~9)
- ⚠️ Special attention: WHO and FDA DO NOT recommend nonoxynol-9 for rectal use! Damages rectal mucosa, increases HIV infection risk 2–5 times. Use only for vaginal contraception with informed consent.
- Critical parameters:
- Assay: 98.0–102.0%
- Nonylphenol: ≤0.1% (ENDOCRINE DISRUPTOR!)
- 1,4-Dioxane: ≤10 ppm (CARCINOGEN!)
- Ethylene oxide: ≤1 ppm
- Propylene oxide: ≤1 ppm
- Heavy metals: ≤20 ppm
- Loss on drying: ≤1.0%
- Sulfated ash: ≤0.1%
- Hydroxyl value: 50–65 mg KOH/g
- Acid value: ≤1.0 mg KOH/g
- Peroxide value: ≤5.0 mmol/kg (oxidation control!)
- Refractive index: 1.485–1.495
- Density (25°C): 1.050–1.070 g/mL
- Color: ≤100 APHA
- Residual solvents: ethanol ≤5000 ppm, acetone ≤5000 ppm
5. URS — user requirements
| ID | Requirement | Criticality | Acceptance criterion |
|---|---|---|---|
| URS-001 | The system shall accept an input.csv file for Nonoxynol9 with the exact columns listed in the “Input data contract” section. | High | A file with the correct header is processed without manual editing; missing mandatory columns produce FAIL/import error. |
| URS-002 | The system shall support execution without arguments in demo mode and execution with input.csv output.json for user data. | Medium | Both execution scenarios produce a predictable result or clear diagnostic error. |
| URS-003 | The system shall perform rule-based controls for: assay / content, residual solvents, heavy metals / elemental impurities, pH and physicochemical parameters. | High | Each controlled parameter receives a status and message; the result does not depend on hidden Excel formulas or ML. |
| URS-004 | The system shall preserve traceability between batch/lot, source values, applied rules and final verdict. | High | Output includes batch identifier, source values, parameter statuses and critical findings. |
| URS-005 | The system shall generate machine-readable output.json for LIMS/ELN/MES, batch record and QA/QC review. | High | JSON contains overall status, check array, warnings, failures and source-file reference. |
| URS-006 | The system shall support use in the client validation package: URS/FS, IQ/OQ preparation, installation and operational scenario checks. | High | The document, test scenarios and reproducible CSV/JSON flow are suitable for audit and internal approval. |
| URS-007 | The system shall clearly separate technical data errors from specification nonconformities. | Medium | Schema/type errors are not mixed with pharmacopoeial deviations and are reported separately. |
6. input.csv data contract
The source of truth for the input schema is the actual input.csv header. Column names are technical identifiers and are not translated.
| # | Column | Type | Unit | Description | Sample | Control rule |
|---|---|---|---|---|---|---|
| 1 | BatchNumber | identifier | as specified | Batch Number | NO9-2026-001 | mandatory field; used for batch/lot traceability |
| 2 | AssayPercent | decimal | % | Assay % | 99.5 | numeric value; compared with assay/purity limit from specification or method |
| 3 | NonylphenolPercent | decimal | % | Nonylphenol % | 0.05 | mandatory numeric value; rule comparison is performed by the utility |
| 4 | DioxanePPM | decimal | ppm | Dioxane PPM | 5 | mandatory numeric value; rule comparison is performed by the utility |
| 5 | EthyleneOxidePPM | decimal | ppm | Ethylene Oxide PPM | 0.5 | mandatory numeric value; rule comparison is performed by the utility |
| 6 | PropyleneOxidePPM | decimal | ppm | Propylene Oxide PPM | 0.3 | mandatory numeric value; rule comparison is performed by the utility |
| 7 | HeavyMetalsPPM | decimal | ppm | Heavy Metals PPM | 10 | numeric value; checked as elemental/metal impurity |
| 8 | LossOnDryingPercent | decimal | % | Loss On Drying % | 0.5 | mandatory numeric value; rule comparison is performed by the utility |
| 9 | SulfatedAshPercent | decimal | % | Sulfated Ash % | 0.05 | mandatory numeric value; rule comparison is performed by the utility |
| 10 | HydroxylValue | decimal | as specified | Hydroxyl Value | 58.0 | mandatory numeric value; rule comparison is performed by the utility |
| 11 | AcidValue | decimal | as specified | Acid Value | 0.8 | mandatory numeric value; rule comparison is performed by the utility |
| 12 | PeroxideValue | decimal | as specified | Peroxide Value | 3.0 | mandatory numeric value; rule comparison is performed by the utility |
| 13 | RefractiveIndex | decimal | as specified | Refractive Index | 1.490 | mandatory numeric value; rule comparison is performed by the utility |
| 14 | DensityGPerMl | decimal | as specified | Density GPer Ml | 1.060 | mandatory numeric value; rule comparison is performed by the utility |
| 15 | ColorAPHA | decimal | as specified | Color APHA | 50 | mandatory numeric value; rule comparison is performed by the utility |
| 16 | EthanolPPM | decimal | ppm | Ethanol PPM | 800 | numeric value; checked as residual solvent against the applicable limit |
| 17 | AcetonePPM | decimal | ppm | Acetone PPM | 500 | numeric value; checked as residual solvent against the applicable limit |
CSV example
BatchNumber,AssayPercent,NonylphenolPercent,DioxanePPM,EthyleneOxidePPM,PropyleneOxidePPM,HeavyMetalsPPM,LossOnDryingPercent,SulfatedAshPercent,HydroxylValue,AcidValue,PeroxideValue,RefractiveIndex,DensityGPerMl,ColorAPHA,EthanolPPM,AcetonePPM NO9-2026-001,99.5,0.05,5,0.5,0.3,10,0.5,0.05,58.0,0.8,3.0,1.490,1.060,50,800,500
7. FS — functional specification
| ID | Function | Implementation description |
|---|---|---|
| FS-001 | CLI entry point | The executable Nonoxynol9QualityChecker.exe supports demo mode and input.csv output.json processing mode. |
| FS-002 | CSV parser | The import module reads CSV, validates header, column presence/order, value count and encoding. Decimal values are expected with a dot separator. |
| FS-003 | Field conversion | Each column is converted to the expected type: identifier, text, decimal number, date/time or boolean flag. |
| FS-004 | Domain rule engine | For Nonoxynol9, explicit rules are applied: range, minimum, maximum, absence of prohibited flag, data completeness or calculation-based check. |
| FS-005 | Criticality handling | Critical violations produce FAIL; non-critical deviations and incomplete data produce WARNING; full conformance produces PASS. |
| FS-006 | JSON writer | output.json stores overall status, per-parameter results, source values, warnings, failures and diagnostic messages. |
| FS-007 | Integration contract | The CSV → JSON format is stable for invocation from LIMS/ELN/MES, scheduled task or wrapper service. |
| FS-008 | Error handling | Schema error, missing file, non-numeric value or JSON write failure returns diagnosable error without silent PASS. |
8. output.json contract
The output file must be suitable for automated processing, audit review and correlation with the source input.csv row.
{
"utility": "Nonoxynol9QualityChecker",
"api": "Nonoxynol9",
"batchNumber": "NO9-2026-001",
"overallStatus": "PASS|WARNING|FAIL",
"checkedAtUtc": "2026-05-18T00:00:00Z",
"checks": [
{
"parameter": "BatchNumber",
"value": "NO9-2026-001",
"unit": "as specified",
"status": "PASS|WARNING|FAIL",
"message": "Rule-based check result"
},
{
"parameter": "AssayPercent",
"value": "99.5",
"unit": "%",
"status": "PASS|WARNING|FAIL",
"message": "Rule-based check result"
},
{
"parameter": "NonylphenolPercent",
"value": "0.05",
"unit": "%",
"status": "PASS|WARNING|FAIL",
"message": "Rule-based check result"
},
{
"parameter": "DioxanePPM",
"value": "5",
"unit": "ppm",
"status": "PASS|WARNING|FAIL",
"message": "Rule-based check result"
},
{
"parameter": "EthyleneOxidePPM",
"value": "0.5",
"unit": "ppm",
"status": "PASS|WARNING|FAIL",
"message": "Rule-based check result"
},
{
"parameter": "PropyleneOxidePPM",
"value": "0.3",
"unit": "ppm",
"status": "PASS|WARNING|FAIL",
"message": "Rule-based check result"
},
{
"parameter": "HeavyMetalsPPM",
"value": "10",
"unit": "ppm",
"status": "PASS|WARNING|FAIL",
"message": "Rule-based check result"
},
{
"parameter": "LossOnDryingPercent",
"value": "0.5",
"unit": "%",
"status": "PASS|WARNING|FAIL",
"message": "Rule-based check result"
}
],
"criticalFindings": [],
"sourceFile": "input.csv"
}9. OQ/PQ test scenarios
| ID | Scenario | Expected result |
|---|---|---|
| TC-001 | Valid CSV with expected header and sample row | All rows are processed; output contains PASS/WARNING/FAIL and parameter-level detail. |
| TC-002 | A mandatory input.csv column is missing | Import is rejected or the row receives FAIL with schema reference. |
| TC-003 | A numeric field contains text or a blank value | Type conversion error is recorded; the result is not hidden as PASS. |
| TC-004 | A parameter is outside specification or critical limit | Critical parameters produce FAIL; non-critical deviations produce WARNING according to the rule. |
| TC-007 | Residual solvent above applicable limit | FAIL is produced with solvent name and measured value. |
10. QA/QC, CSV and change control
- Before production use, the client records executable version, checksum, specification/monograph version, test CSV, expected JSON and IQ/OQ results.
- Column names must not be changed without updating the validator and test scenarios.
- The source CSV, output.json and utility version should be stored together as an evidence package.
- Any change in control rules must go through change control and repeated OQ scenario verification.
Included in packages
Contraceptives QC Suite
Quality-control package for contraceptives: hormonal APIs, fixed combinations, implants, rings and intrauterine systems.
OpenEndocrinology QC Suite
QC package for endocrinology: thyroid, pituitary/peptide hormones, corticosteroids, sex hormones and selected metabolic medicines.
OpenGynecology QC Suite
QC package for gynecology: hormones, contraceptives, uterotonics, anti-infectives and women’s-health medicines.
OpenProctology QC Suite
QC package for proctology: local anaesthetics, corticosteroids, anti-inflammatory, anti-infective and supporting medicines for rectal dosage forms.
Open