Nonoxynol9QualityChecker

Nonoxynol9

assay contraceptives fixed-dose combinations heavy metals hormones impurities residual solvents
Open selection

Nonoxynol-9 Quality Checker — Nonoxynol-9 (Spermicidal Surfactant) (Ph. Eur. 2.8.1)

ℹ️ The utility checks assay, critical impurities (nonylphenol, 1,4-dioxane, ethylene/propylene oxide), physicochemical parameters (hydroxyl/acid value, peroxide value, refractive index, density).
ℹ️ Does not use machine learning — rule-based logic only.
⚠️ CRITICAL: Nonylphenol (≤0.1%) — ENDORINE DISRUPTOR! 1,4-Dioxane (≤10 ppm) — CARCINOGEN! Peroxide value (≤5.0) — oxidation control! Nonoxynol-9 NOT recommended for rectal use (HIV risk)!

Usage:
Nonoxynol9QualityChecker.exe → demo mode (console output)
Nonoxynol9QualityChecker.exe input.csv output.json → evaluate your data

Input format:
BatchNumber,AssayPercent,NonylphenolPercent,DioxanePPM,EthyleneOxidePPM,PropyleneOxidePPM,HeavyMetalsPPM,LossOnDryingPercent,SulfatedAshPercent,HydroxylValue,AcidValue,PeroxideValue,RefractiveIndex,DensityGPerMl,ColorAPHA,EthanolPPM,AcetonePPM

Example:
NO9-2026-001,99.5,0.05,5,0.5,0.3,10,0.5,0.05,58.0,0.8,3.0,1.490,1.060,50,800,500

— WHY IS THIS NEEDED?
Nonoxynol-9 — nonionic surfactant used as spermicide in:
• Vaginal gels, creams, films (Emko, Pharmatex)
• Condoms with spermicidal lubricant
• Diaphragms and caps with application
⚠️ CRITICAL:
• Nonylphenol ≤0.1% — ENDORINE DISRUPTOR! Disrupts hormonal balance, toxic to reproductive system. Mandatory control!
• 1,4-Dioxane ≤10 ppm — CARCINOGEN group 2A (IARC)! Forms during ethoxylation. Strict limit!
• Ethylene oxide/propylene oxide ≤1 ppm — residual monomers, potential carcinogens
• Peroxide value ≤5.0 mmol/kg — nonoxynol-9 oxidation-sensitive! High value = reduced spermicidal activity + toxic products
• Hydroxyl value 50–65 mg KOH/g — confirms degree of ethoxylation (~9)
⚠️ Special attention: WHO and FDA DO NOT recommend nonoxynol-9 for rectal use! Damages rectal mucosa, increases HIV infection risk 2–5 times. Use only for vaginal contraception with informed consent.
Critical parameters:
• Assay: 98.0–102.0%
• Nonylphenol: ≤0.1% (ENDOCRINE DISRUPTOR!)
• 1,4-Dioxane: ≤10 ppm (CARCINOGEN!)
• Ethylene oxide: ≤1 ppm
• Propylene oxide: ≤1 ppm
• Heavy metals: ≤20 ppm
• Loss on drying: ≤1.0%
• Sulfated ash: ≤0.1%
• Hydroxyl value: 50–65 mg KOH/g
• Acid value: ≤1.0 mg KOH/g
• Peroxide value: ≤5.0 mmol/kg (oxidation control!)
• Refractive index: 1.485–1.495
• Density (25°C): 1.050–1.070 g/mL
• Color: ≤100 APHA
• Residual solvents: ethanol ≤5000 ppm, acetone ≤5000 ppm
⚠️ Note: Nonoxynol-9 is a MIXTURE of polyethylene glycol ethers of nonylphenol with average ethoxylation degree 9. Assay determined as sum of HPLC peaks. Impurity control critical for safety! Store in tightly closed container, protected from light and moisture. Analyze quickly — oxidation-sensitive.

input.csv

BatchNumber,AssayPercent,NonylphenolPercent,DioxanePPM,EthyleneOxidePPM,PropyleneOxidePPM,HeavyMetalsPPM,LossOnDryingPercent,SulfatedAshPercent,HydroxylValue,AcidValue,PeroxideValue,RefractiveIndex,DensityGPerMl,ColorAPHA,EthanolPPM,AcetonePPM
NO9-2026-001,99.5,0.05,5,0.5,0.3,10,0.5,0.05,58.0,0.8,3.0,1.490,1.060,50,800,500

URS & FS — user requirements and functional specification

This document defines user requirements and functional specification for the quality-control utility. It supports deployment discussion, IQ/OQ preparation and QC workflow integration.

Utility: Nonoxynol9QualityCheckerAPI / object: Nonoxynol9Category: Contraceptives

1. Scope

The Nonoxynol9 Quality Checker utility is used for Nonoxynol9. The actual input.csv is the source of truth for the input structure; control criteria are defined by the executable and the domain description.

The utility does not use machine learning; decisions are produced by deterministic rules.

Categories: Contraceptives

Tags: assay, contraceptives, fixed-dose combinations, heavy metals, hormones, impurities, residual solvents

2. Execution modes

Nonoxynol9QualityChecker.exe                            → demo mode (console output)
Nonoxynol9QualityChecker.exe input.csv output.json      → evaluate your data

3. Key controlled areas

  • assay / content
  • residual solvents
  • heavy metals / elemental impurities
  • pH and physicochemical parameters

4. Domain limits and critical parameters

  • ⚠️ CRITICAL: Nonylphenol (≤0.1%) — ENDORINE DISRUPTOR! 1,4-Dioxane (≤10 ppm) — CARCINOGEN! Peroxide value (≤5.0) — oxidation control! Nonoxynol-9 NOT recommended for rectal use (HIV risk)!
  • ⚠️ CRITICAL:
  • Nonylphenol ≤0.1% — ENDORINE DISRUPTOR! Disrupts hormonal balance, toxic to reproductive system. Mandatory control!
  • 1,4-Dioxane ≤10 ppm — CARCINOGEN group 2A (IARC)! Forms during ethoxylation. Strict limit!
  • Ethylene oxide/propylene oxide ≤1 ppm — residual monomers, potential carcinogens
  • Peroxide value ≤5.0 mmol/kg — nonoxynol-9 oxidation-sensitive! High value = reduced spermicidal activity + toxic products
  • Hydroxyl value 50–65 mg KOH/g — confirms degree of ethoxylation (~9)
  • ⚠️ Special attention: WHO and FDA DO NOT recommend nonoxynol-9 for rectal use! Damages rectal mucosa, increases HIV infection risk 2–5 times. Use only for vaginal contraception with informed consent.
  • Critical parameters:
  • Assay: 98.0–102.0%
  • Nonylphenol: ≤0.1% (ENDOCRINE DISRUPTOR!)
  • 1,4-Dioxane: ≤10 ppm (CARCINOGEN!)
  • Ethylene oxide: ≤1 ppm
  • Propylene oxide: ≤1 ppm
  • Heavy metals: ≤20 ppm
  • Loss on drying: ≤1.0%
  • Sulfated ash: ≤0.1%
  • Hydroxyl value: 50–65 mg KOH/g
  • Acid value: ≤1.0 mg KOH/g
  • Peroxide value: ≤5.0 mmol/kg (oxidation control!)
  • Refractive index: 1.485–1.495
  • Density (25°C): 1.050–1.070 g/mL
  • Color: ≤100 APHA
  • Residual solvents: ethanol ≤5000 ppm, acetone ≤5000 ppm
Limits stated in the description must be verified against the current approved specification, pharmacopoeial monograph and registration dossier before production use.

5. URS — user requirements

IDRequirementCriticalityAcceptance criterion
URS-001The system shall accept an input.csv file for Nonoxynol9 with the exact columns listed in the “Input data contract” section.HighA file with the correct header is processed without manual editing; missing mandatory columns produce FAIL/import error.
URS-002The system shall support execution without arguments in demo mode and execution with input.csv output.json for user data.MediumBoth execution scenarios produce a predictable result or clear diagnostic error.
URS-003The system shall perform rule-based controls for: assay / content, residual solvents, heavy metals / elemental impurities, pH and physicochemical parameters.HighEach controlled parameter receives a status and message; the result does not depend on hidden Excel formulas or ML.
URS-004The system shall preserve traceability between batch/lot, source values, applied rules and final verdict.HighOutput includes batch identifier, source values, parameter statuses and critical findings.
URS-005The system shall generate machine-readable output.json for LIMS/ELN/MES, batch record and QA/QC review.HighJSON contains overall status, check array, warnings, failures and source-file reference.
URS-006The system shall support use in the client validation package: URS/FS, IQ/OQ preparation, installation and operational scenario checks.HighThe document, test scenarios and reproducible CSV/JSON flow are suitable for audit and internal approval.
URS-007The system shall clearly separate technical data errors from specification nonconformities.MediumSchema/type errors are not mixed with pharmacopoeial deviations and are reported separately.

6. input.csv data contract

The source of truth for the input schema is the actual input.csv header. Column names are technical identifiers and are not translated.

#ColumnTypeUnitDescriptionSampleControl rule
1BatchNumberidentifieras specifiedBatch NumberNO9-2026-001mandatory field; used for batch/lot traceability
2AssayPercentdecimal%Assay %99.5numeric value; compared with assay/purity limit from specification or method
3NonylphenolPercentdecimal%Nonylphenol %0.05mandatory numeric value; rule comparison is performed by the utility
4DioxanePPMdecimalppmDioxane PPM5mandatory numeric value; rule comparison is performed by the utility
5EthyleneOxidePPMdecimalppmEthylene Oxide PPM0.5mandatory numeric value; rule comparison is performed by the utility
6PropyleneOxidePPMdecimalppmPropylene Oxide PPM0.3mandatory numeric value; rule comparison is performed by the utility
7HeavyMetalsPPMdecimalppmHeavy Metals PPM10numeric value; checked as elemental/metal impurity
8LossOnDryingPercentdecimal%Loss On Drying %0.5mandatory numeric value; rule comparison is performed by the utility
9SulfatedAshPercentdecimal%Sulfated Ash %0.05mandatory numeric value; rule comparison is performed by the utility
10HydroxylValuedecimalas specifiedHydroxyl Value58.0mandatory numeric value; rule comparison is performed by the utility
11AcidValuedecimalas specifiedAcid Value0.8mandatory numeric value; rule comparison is performed by the utility
12PeroxideValuedecimalas specifiedPeroxide Value3.0mandatory numeric value; rule comparison is performed by the utility
13RefractiveIndexdecimalas specifiedRefractive Index1.490mandatory numeric value; rule comparison is performed by the utility
14DensityGPerMldecimalas specifiedDensity GPer Ml1.060mandatory numeric value; rule comparison is performed by the utility
15ColorAPHAdecimalas specifiedColor APHA50mandatory numeric value; rule comparison is performed by the utility
16EthanolPPMdecimalppmEthanol PPM800numeric value; checked as residual solvent against the applicable limit
17AcetonePPMdecimalppmAcetone PPM500numeric value; checked as residual solvent against the applicable limit

CSV example

BatchNumber,AssayPercent,NonylphenolPercent,DioxanePPM,EthyleneOxidePPM,PropyleneOxidePPM,HeavyMetalsPPM,LossOnDryingPercent,SulfatedAshPercent,HydroxylValue,AcidValue,PeroxideValue,RefractiveIndex,DensityGPerMl,ColorAPHA,EthanolPPM,AcetonePPM
NO9-2026-001,99.5,0.05,5,0.5,0.3,10,0.5,0.05,58.0,0.8,3.0,1.490,1.060,50,800,500

7. FS — functional specification

IDFunctionImplementation description
FS-001CLI entry pointThe executable Nonoxynol9QualityChecker.exe supports demo mode and input.csv output.json processing mode.
FS-002CSV parserThe import module reads CSV, validates header, column presence/order, value count and encoding. Decimal values are expected with a dot separator.
FS-003Field conversionEach column is converted to the expected type: identifier, text, decimal number, date/time or boolean flag.
FS-004Domain rule engineFor Nonoxynol9, explicit rules are applied: range, minimum, maximum, absence of prohibited flag, data completeness or calculation-based check.
FS-005Criticality handlingCritical violations produce FAIL; non-critical deviations and incomplete data produce WARNING; full conformance produces PASS.
FS-006JSON writeroutput.json stores overall status, per-parameter results, source values, warnings, failures and diagnostic messages.
FS-007Integration contractThe CSV → JSON format is stable for invocation from LIMS/ELN/MES, scheduled task or wrapper service.
FS-008Error handlingSchema error, missing file, non-numeric value or JSON write failure returns diagnosable error without silent PASS.

8. output.json contract

The output file must be suitable for automated processing, audit review and correlation with the source input.csv row.

{
  "utility": "Nonoxynol9QualityChecker",
  "api": "Nonoxynol9",
  "batchNumber": "NO9-2026-001",
  "overallStatus": "PASS|WARNING|FAIL",
  "checkedAtUtc": "2026-05-18T00:00:00Z",
  "checks": [
    {
      "parameter": "BatchNumber",
      "value": "NO9-2026-001",
      "unit": "as specified",
      "status": "PASS|WARNING|FAIL",
      "message": "Rule-based check result"
    },
    {
      "parameter": "AssayPercent",
      "value": "99.5",
      "unit": "%",
      "status": "PASS|WARNING|FAIL",
      "message": "Rule-based check result"
    },
    {
      "parameter": "NonylphenolPercent",
      "value": "0.05",
      "unit": "%",
      "status": "PASS|WARNING|FAIL",
      "message": "Rule-based check result"
    },
    {
      "parameter": "DioxanePPM",
      "value": "5",
      "unit": "ppm",
      "status": "PASS|WARNING|FAIL",
      "message": "Rule-based check result"
    },
    {
      "parameter": "EthyleneOxidePPM",
      "value": "0.5",
      "unit": "ppm",
      "status": "PASS|WARNING|FAIL",
      "message": "Rule-based check result"
    },
    {
      "parameter": "PropyleneOxidePPM",
      "value": "0.3",
      "unit": "ppm",
      "status": "PASS|WARNING|FAIL",
      "message": "Rule-based check result"
    },
    {
      "parameter": "HeavyMetalsPPM",
      "value": "10",
      "unit": "ppm",
      "status": "PASS|WARNING|FAIL",
      "message": "Rule-based check result"
    },
    {
      "parameter": "LossOnDryingPercent",
      "value": "0.5",
      "unit": "%",
      "status": "PASS|WARNING|FAIL",
      "message": "Rule-based check result"
    }
  ],
  "criticalFindings": [],
  "sourceFile": "input.csv"
}

9. OQ/PQ test scenarios

IDScenarioExpected result
TC-001Valid CSV with expected header and sample rowAll rows are processed; output contains PASS/WARNING/FAIL and parameter-level detail.
TC-002A mandatory input.csv column is missingImport is rejected or the row receives FAIL with schema reference.
TC-003A numeric field contains text or a blank valueType conversion error is recorded; the result is not hidden as PASS.
TC-004A parameter is outside specification or critical limitCritical parameters produce FAIL; non-critical deviations produce WARNING according to the rule.
TC-007Residual solvent above applicable limitFAIL is produced with solvent name and measured value.

10. QA/QC, CSV and change control

  • Before production use, the client records executable version, checksum, specification/monograph version, test CSV, expected JSON and IQ/OQ results.
  • Column names must not be changed without updating the validator and test scenarios.
  • The source CSV, output.json and utility version should be stored together as an evidence package.
  • Any change in control rules must go through change control and repeated OQ scenario verification.

Included in packages

Contraceptives QC Suite

Quality-control package for contraceptives: hormonal APIs, fixed combinations, implants, rings and intrauterine systems.

Open

Endocrinology QC Suite

QC package for endocrinology: thyroid, pituitary/peptide hormones, corticosteroids, sex hormones and selected metabolic medicines.

Open

Gynecology QC Suite

QC package for gynecology: hormones, contraceptives, uterotonics, anti-infectives and women’s-health medicines.

Open

Proctology QC Suite

QC package for proctology: local anaesthetics, corticosteroids, anti-inflammatory, anti-infective and supporting medicines for rectal dosage forms.

Open