MiconazoleQualityChecker
Miconazole
Miconazole Quality Checker — Miconazole quality assessment (Ph. Eur. 0398)
ℹ️ The utility verifies that key parameters of miconazole comply with European Pharmacopoeia requirements.
ℹ️ Does not use machine learning — rule-based logic only.
⚠️ Monoclonazol impurity ≤0.1%. Water content ≤0.5%. Appearance must be white.
Usage:
MiconazoleQualityChecker.exe → demo mode (console output)
MiconazoleQualityChecker.exe input.csv output.json → evaluate your data
Input format:
ProductName,BatchNumber,Appearance,Assay_percent,Monoclonazol_percent,WaterContent_percent,MeltingRangeCelsius
Example:
Miconazole_API,B20250417,WhiteOrAlmostWhiteCrystallinePowder,99.5,0.08,0.3,"DecomposesAbove190"
— WHY IS THIS NEEDED?
Miconazole contains a light- and oxygen-sensitive structure. Under UV and oxidants, it degrades to monoclonazol and other products that:
• Lack antifungal activity,
• May reduce efficacy in candidiasis and dermatomycosis treatment,
• Indicate improper storage conditions (light protection is mandatory).
Compliance with Ph. Eur. 0398 is mandatory for imidazole antifungal drug release.
input.csv
ProductName,BatchNumber,Appearance,Assay_percent,Monoclonazol_percent,WaterContent_percent,MeltingRangeCelsius Miconazole_API,B20250417,WhiteOrAlmostWhiteCrystallinePowder,99.5,0.08,0.3,"DecomposesAbove190"
URS & FS — user requirements and functional specification
This document defines user requirements and functional specification for the quality-control utility. It supports deployment discussion, IQ/OQ preparation and QC workflow integration.
1. Scope
The Miconazole Quality Checker utility is used for Miconazole. The actual input.csv is the source of truth for the input structure; control criteria are defined by the executable and the domain description.
The utility does not use machine learning; decisions are produced by deterministic rules.
Categories: BP monographs
Tags: API, assay, British Pharmacopoeia, impurities, medical gases, monographs, specification, water quality
2. Execution modes
MiconazoleQualityChecker.exe → demo mode (console output) MiconazoleQualityChecker.exe input.csv output.json → evaluate your data
3. Key controlled areas
- assay / content
- pH and physicochemical parameters
4. Domain limits and critical parameters
- ⚠️ Monoclonazol impurity ≤0.1%. Water content ≤0.5%. Appearance must be white.
5. URS — user requirements
| ID | Requirement | Criticality | Acceptance criterion |
|---|---|---|---|
| URS-001 | The system shall accept an input.csv file for Miconazole with the exact columns listed in the “Input data contract” section. | High | A file with the correct header is processed without manual editing; missing mandatory columns produce FAIL/import error. |
| URS-002 | The system shall support execution without arguments in demo mode and execution with input.csv output.json for user data. | Medium | Both execution scenarios produce a predictable result or clear diagnostic error. |
| URS-003 | The system shall perform rule-based controls for: assay / content, pH and physicochemical parameters. | High | Each controlled parameter receives a status and message; the result does not depend on hidden Excel formulas or ML. |
| URS-004 | The system shall preserve traceability between batch/lot, source values, applied rules and final verdict. | High | Output includes batch identifier, source values, parameter statuses and critical findings. |
| URS-005 | The system shall generate machine-readable output.json for LIMS/ELN/MES, batch record and QA/QC review. | High | JSON contains overall status, check array, warnings, failures and source-file reference. |
| URS-006 | The system shall support use in the client validation package: URS/FS, IQ/OQ preparation, installation and operational scenario checks. | High | The document, test scenarios and reproducible CSV/JSON flow are suitable for audit and internal approval. |
| URS-007 | The system shall clearly separate technical data errors from specification nonconformities. | Medium | Schema/type errors are not mixed with pharmacopoeial deviations and are reported separately. |
6. input.csv data contract
The source of truth for the input schema is the actual input.csv header. Column names are technical identifiers and are not translated.
| # | Column | Type | Unit | Description | Sample | Control rule |
|---|---|---|---|---|---|---|
| 1 | ProductName | identifier | as specified | Product Name | Miconazole_API | mandatory value; format and acceptability are checked by the utility |
| 2 | BatchNumber | identifier | as specified | Batch Number | B20250417 | mandatory field; used for batch/lot traceability |
| 3 | Appearance | text | as specified | Appearance | WhiteOrAlmostWhiteCrystallinePowder | mandatory value; format and acceptability are checked by the utility |
| 4 | Assay_percent | decimal | % | Assay percent | 99.5 | numeric value; compared with assay/purity limit from specification or method |
| 5 | Monoclonazol_percent | decimal | % | Monoclonazol percent | 0.08 | mandatory numeric value; rule comparison is performed by the utility |
| 6 | WaterContent_percent | decimal | % | Water Content percent | 0.3 | numeric value; compared with assay/purity limit from specification or method |
| 7 | MeltingRangeCelsius | decimal | °C | Melting Range Celsius | DecomposesAbove190 | mandatory value; format and acceptability are checked by the utility |
CSV example
ProductName,BatchNumber,Appearance,Assay_percent,Monoclonazol_percent,WaterContent_percent,MeltingRangeCelsius Miconazole_API,B20250417,WhiteOrAlmostWhiteCrystallinePowder,99.5,0.08,0.3,"DecomposesAbove190"
7. FS — functional specification
| ID | Function | Implementation description |
|---|---|---|
| FS-001 | CLI entry point | The executable MiconazoleQualityChecker.exe supports demo mode and input.csv output.json processing mode. |
| FS-002 | CSV parser | The import module reads CSV, validates header, column presence/order, value count and encoding. Decimal values are expected with a dot separator. |
| FS-003 | Field conversion | Each column is converted to the expected type: identifier, text, decimal number, date/time or boolean flag. |
| FS-004 | Domain rule engine | For Miconazole, explicit rules are applied: range, minimum, maximum, absence of prohibited flag, data completeness or calculation-based check. |
| FS-005 | Criticality handling | Critical violations produce FAIL; non-critical deviations and incomplete data produce WARNING; full conformance produces PASS. |
| FS-006 | JSON writer | output.json stores overall status, per-parameter results, source values, warnings, failures and diagnostic messages. |
| FS-007 | Integration contract | The CSV → JSON format is stable for invocation from LIMS/ELN/MES, scheduled task or wrapper service. |
| FS-008 | Error handling | Schema error, missing file, non-numeric value or JSON write failure returns diagnosable error without silent PASS. |
8. output.json contract
The output file must be suitable for automated processing, audit review and correlation with the source input.csv row.
{
"utility": "MiconazoleQualityChecker",
"api": "Miconazole",
"batchNumber": "B20250417",
"overallStatus": "PASS|WARNING|FAIL",
"checkedAtUtc": "2026-05-18T00:00:00Z",
"checks": [
{
"parameter": "ProductName",
"value": "Miconazole_API",
"unit": "as specified",
"status": "PASS|WARNING|FAIL",
"message": "Rule-based check result"
},
{
"parameter": "BatchNumber",
"value": "B20250417",
"unit": "as specified",
"status": "PASS|WARNING|FAIL",
"message": "Rule-based check result"
},
{
"parameter": "Appearance",
"value": "WhiteOrAlmostWhiteCrystallinePowder",
"unit": "as specified",
"status": "PASS|WARNING|FAIL",
"message": "Rule-based check result"
},
{
"parameter": "Assay_percent",
"value": "99.5",
"unit": "%",
"status": "PASS|WARNING|FAIL",
"message": "Rule-based check result"
},
{
"parameter": "Monoclonazol_percent",
"value": "0.08",
"unit": "%",
"status": "PASS|WARNING|FAIL",
"message": "Rule-based check result"
},
{
"parameter": "WaterContent_percent",
"value": "0.3",
"unit": "%",
"status": "PASS|WARNING|FAIL",
"message": "Rule-based check result"
},
{
"parameter": "MeltingRangeCelsius",
"value": "DecomposesAbove190",
"unit": "°C",
"status": "PASS|WARNING|FAIL",
"message": "Rule-based check result"
}
],
"criticalFindings": [],
"sourceFile": "input.csv"
}9. OQ/PQ test scenarios
| ID | Scenario | Expected result |
|---|---|---|
| TC-001 | Valid CSV with expected header and sample row | All rows are processed; output contains PASS/WARNING/FAIL and parameter-level detail. |
| TC-002 | A mandatory input.csv column is missing | Import is rejected or the row receives FAIL with schema reference. |
| TC-003 | A numeric field contains text or a blank value | Type conversion error is recorded; the result is not hidden as PASS. |
| TC-004 | A parameter is outside specification or critical limit | Critical parameters produce FAIL; non-critical deviations produce WARNING according to the rule. |
10. QA/QC, CSV and change control
- Before production use, the client records executable version, checksum, specification/monograph version, test CSV, expected JSON and IQ/OQ results.
- Column names must not be changed without updating the validator and test scenarios.
- The source CSV, output.json and utility version should be stored together as an evidence package.
- Any change in control rules must go through change control and repeated OQ scenario verification.
Included in packages
British Pharmacopoeia Monographs QC Suite
Utility package for British Pharmacopoeia monographs covering drug substances, APIs and finished products.
OpenInfectious Diseases QC Suite
QC utility package for infectious diseases: antibacterial, antiviral, antifungal and antiparasitic products, microbiology, sterility, endotoxins, viral safety and vaccine release checks.
Open