HyaluronicAcidFillerQualityChecker
Hyaluronic Acid Filler
HA Filler Quality Checker — Hyaluronic Acid Dermal Fillers (ISO 13485, EU MDR)
ℹ️ The utility checks HA concentration, crosslinking degree, residual BDDE, rheology (G', viscosity), particle size, osmolality, sterility, endotoxins.
ℹ️ Does not use machine learning — rule-based logic only.
⚠️ CRITICAL! Residual BDDE ≤ 2 ppm (toxic). Sterility and endotoxins mandatory. Rheology determines injection site!
Usage:
HyaluronicAcidFillerQualityChecker.exe → demo mode
HyaluronicAcidFillerQualityChecker.exe input.csv output.json → evaluate data
Input format:
BatchNumber,HA_Concentration_mgPerMl,Crosslinking_Degree_Percent,Residual_BDDE_ppm,Particle_Size_um,Viscosity_Pa_s,G_Prime_Pa,G_DoublePrime_Pa,Swelling_Ratio,pH_Value,Osmolality_mOsm_kg,Endotoxin_EU_ml,SterilityTest,PackagingIntegrityTest,Protein_Residue_ppm
Example:
HA-FILL-2026-001,24.0,1.5,1.2,250.0,25.0,450.0,150.0,12.0,7.1,300.0,0.15,0,0,5.0
— WHY IS THIS NEEDED?
Hyaluronic Acid (HA) dermal fillers — most popular injectable products for contour plasty:
• Juvederm, Restylane, Teosyal, Belotero, Revanesse etc.
• Crosslinked HA provides long-term volume and collagen stimulation
• Rheological properties (G', viscosity) dictate where to inject (deep, superficial, lips, tear trough)
⚠️ CRITICAL:
• Residual BDDE ≤ 2 ppm — 1,4-butanediol diglycidyl ether used for crosslinking, but TOXIC in free form. Strict limit!
• Crosslinking Degree 0.5–4.0% — determines gel density and degradation rate
• HA Concentration 20–26 mg/mL — standard for most medium-density fillers
• Elastic Modulus (G') — key selection parameter: high G' for bone/cartilage, low G' for superficial wrinkles
• Particle Size — must match needle gauge (typically < 500 µm for 27G/30G passage)
• Osmolality 250–350 mOsm/kg — isotonicity prevents post-injection swelling
• Sterility and Endotoxins — MANDATORY for all injectable forms
• Protein (for non-biofermented HA) — ≤ 10 ppm (allergy risk)
⚠️ Note: Rheology (G', G'', tan δ) measured on rheometer. G' (elastic modulus) shows ability to restore shape (lifting capacity). High G' = high lifting force. Residual BDDE removed by multi-step purification, its control critical for safety. Osmolality must be close to physiological to prevent fluid influx and swelling. Sterility ensured by terminal sterilization or aseptic filling.
input.csv
BatchNumber,HA_Concentration_mgPerMl,Crosslinking_Degree_Percent,Residual_BDDE_ppm,Particle_Size_um,Viscosity_Pa_s,G_Prime_Pa,G_DoublePrime_Pa,Swelling_Ratio,pH_Value,Osmolality_mOsm_kg,Endotoxin_EU_ml,SterilityTest,PackagingIntegrityTest,Protein_Residue_ppm HA-FILL-2026-001,24.0,1.5,1.2,250.0,25.0,450.0,150.0,12.0,7.1,300.0,0.15,0,0,5.0
URS & FS — user requirements and functional specification
This document defines user requirements and functional specification for the quality-control utility. It supports deployment discussion, IQ/OQ preparation and QC workflow integration.
1. Scope
The Hyaluronic Acid Filler Quality Checker utility is used for Hyaluronic Acid Filler. The actual input.csv is the source of truth for the input structure; control criteria are defined by the executable and the domain description.
The utility does not use machine learning; decisions are produced by deterministic rules.
Categories: Dermal fillers
Tags: dermal fillers, endotoxins, hyaluronic acid, injectables, particles, rheology, sterility
2. Execution modes
HyaluronicAcidFillerQualityChecker.exe → demo mode HyaluronicAcidFillerQualityChecker.exe input.csv output.json → evaluate data
3. Key controlled areas
- assay / content
- microbiology and pathogens
- pH and physicochemical parameters
4. Domain limits and critical parameters
- ⚠️ CRITICAL! Residual BDDE ≤ 2 ppm (toxic). Sterility and endotoxins mandatory. Rheology determines injection site!
- ⚠️ CRITICAL:
- Residual BDDE ≤ 2 ppm — 1,4-butanediol diglycidyl ether used for crosslinking, but TOXIC in free form. Strict limit!
- Crosslinking Degree 0.5–4.0% — determines gel density and degradation rate
- HA Concentration 20–26 mg/mL — standard for most medium-density fillers
- Elastic Modulus (G') — key selection parameter: high G' for bone/cartilage, low G' for superficial wrinkles
- Particle Size — must match needle gauge (typically < 500 µm for 27G/30G passage)
- Osmolality 250–350 mOsm/kg — isotonicity prevents post-injection swelling
- Sterility and Endotoxins — MANDATORY for all injectable forms
- Protein (for non-biofermented HA) — ≤ 10 ppm (allergy risk)
- ⚠️ Note: Rheology (G', G'', tan δ) measured on rheometer. G' (elastic modulus) shows ability to restore shape (lifting capacity). High G' = high lifting force. Residual BDDE removed by multi-step purification, its control critical for safety. Osmolality must be close to physiological to prevent fluid influx and swelling. Sterility ensured by terminal sterilization or aseptic filling.
5. URS — user requirements
| ID | Requirement | Criticality | Acceptance criterion |
|---|---|---|---|
| URS-001 | The system shall accept an input.csv file for Hyaluronic Acid Filler with the exact columns listed in the “Input data contract” section. | High | A file with the correct header is processed without manual editing; missing mandatory columns produce FAIL/import error. |
| URS-002 | The system shall support execution without arguments in demo mode and execution with input.csv output.json for user data. | Medium | Both execution scenarios produce a predictable result or clear diagnostic error. |
| URS-003 | The system shall perform rule-based controls for: assay / content, microbiology and pathogens, pH and physicochemical parameters. | High | Each controlled parameter receives a status and message; the result does not depend on hidden Excel formulas or ML. |
| URS-004 | The system shall preserve traceability between batch/lot, source values, applied rules and final verdict. | High | Output includes batch identifier, source values, parameter statuses and critical findings. |
| URS-005 | The system shall generate machine-readable output.json for LIMS/ELN/MES, batch record and QA/QC review. | High | JSON contains overall status, check array, warnings, failures and source-file reference. |
| URS-006 | The system shall support use in the client validation package: URS/FS, IQ/OQ preparation, installation and operational scenario checks. | High | The document, test scenarios and reproducible CSV/JSON flow are suitable for audit and internal approval. |
| URS-007 | The system shall clearly separate technical data errors from specification nonconformities. | Medium | Schema/type errors are not mixed with pharmacopoeial deviations and are reported separately. |
6. input.csv data contract
The source of truth for the input schema is the actual input.csv header. Column names are technical identifiers and are not translated.
| # | Column | Type | Unit | Description | Sample | Control rule |
|---|---|---|---|---|---|---|
| 1 | BatchNumber | identifier | as specified | Batch Number | HA-FILL-2026-001 | mandatory field; used for batch/lot traceability |
| 2 | HA_Concentration_mgPerMl | decimal | mg/ml | HA Concentration mg per Ml | 24.0 | numeric value; compared with assay/purity limit from specification or method |
| 3 | Crosslinking_Degree_Percent | decimal | % | Crosslinking Degree % | 1.5 | mandatory numeric value; rule comparison is performed by the utility |
| 4 | Residual_BDDE_ppm | decimal | ppm | Residual BDDE ppm | 1.2 | mandatory numeric value; rule comparison is performed by the utility |
| 5 | Particle_Size_um | decimal | µm | Particle Size um | 250.0 | mandatory numeric value; rule comparison is performed by the utility |
| 6 | Viscosity_Pa_s | decimal | as specified | Viscosity Pa s | 25.0 | mandatory numeric value; rule comparison is performed by the utility |
| 7 | G_Prime_Pa | decimal | as specified | G Prime Pa | 450.0 | mandatory numeric value; rule comparison is performed by the utility |
| 8 | G_DoublePrime_Pa | decimal | as specified | G Double Prime Pa | 150.0 | mandatory numeric value; rule comparison is performed by the utility |
| 9 | Swelling_Ratio | decimal | as specified | Swelling Ratio | 12.0 | mandatory numeric value; rule comparison is performed by the utility |
| 10 | pH_Value | decimal | pH | p H Value | 7.1 | mandatory numeric value; rule comparison is performed by the utility |
| 11 | Osmolality_mOsm_kg | decimal | mOsm/kg | Osmolality m Osm kg | 300.0 | mandatory numeric value; rule comparison is performed by the utility |
| 12 | Endotoxin_EU_ml | decimal | as specified | Endotoxin EU ml | 0.15 | numeric value; critical safety attribute compared with endotoxin limit |
| 13 | SterilityTest | boolean / flag | 0/1 | Sterility Test | 0 | valid flag required; prohibited organisms and growth are normally expected as 0 / absent |
| 14 | PackagingIntegrityTest | decimal | as specified | Packaging Integrity Test | 0 | mandatory numeric value; rule comparison is performed by the utility |
| 15 | Protein_Residue_ppm | decimal | ppm | Protein Residue ppm | 5.0 | mandatory numeric value; rule comparison is performed by the utility |
CSV example
BatchNumber,HA_Concentration_mgPerMl,Crosslinking_Degree_Percent,Residual_BDDE_ppm,Particle_Size_um,Viscosity_Pa_s,G_Prime_Pa,G_DoublePrime_Pa,Swelling_Ratio,pH_Value,Osmolality_mOsm_kg,Endotoxin_EU_ml,SterilityTest,PackagingIntegrityTest,Protein_Residue_ppm HA-FILL-2026-001,24.0,1.5,1.2,250.0,25.0,450.0,150.0,12.0,7.1,300.0,0.15,0,0,5.0
7. FS — functional specification
| ID | Function | Implementation description |
|---|---|---|
| FS-001 | CLI entry point | The executable HyaluronicAcidFillerQualityChecker.exe supports demo mode and input.csv output.json processing mode. |
| FS-002 | CSV parser | The import module reads CSV, validates header, column presence/order, value count and encoding. Decimal values are expected with a dot separator. |
| FS-003 | Field conversion | Each column is converted to the expected type: identifier, text, decimal number, date/time or boolean flag. |
| FS-004 | Domain rule engine | For Hyaluronic Acid Filler, explicit rules are applied: range, minimum, maximum, absence of prohibited flag, data completeness or calculation-based check. |
| FS-005 | Criticality handling | Critical violations produce FAIL; non-critical deviations and incomplete data produce WARNING; full conformance produces PASS. |
| FS-006 | JSON writer | output.json stores overall status, per-parameter results, source values, warnings, failures and diagnostic messages. |
| FS-007 | Integration contract | The CSV → JSON format is stable for invocation from LIMS/ELN/MES, scheduled task or wrapper service. |
| FS-008 | Error handling | Schema error, missing file, non-numeric value or JSON write failure returns diagnosable error without silent PASS. |
8. output.json contract
The output file must be suitable for automated processing, audit review and correlation with the source input.csv row.
{
"utility": "HyaluronicAcidFillerQualityChecker",
"api": "Hyaluronic Acid Filler",
"batchNumber": "HA-FILL-2026-001",
"overallStatus": "PASS|WARNING|FAIL",
"checkedAtUtc": "2026-05-18T00:00:00Z",
"checks": [
{
"parameter": "BatchNumber",
"value": "HA-FILL-2026-001",
"unit": "as specified",
"status": "PASS|WARNING|FAIL",
"message": "Rule-based check result"
},
{
"parameter": "HA_Concentration_mgPerMl",
"value": "24.0",
"unit": "mg/ml",
"status": "PASS|WARNING|FAIL",
"message": "Rule-based check result"
},
{
"parameter": "Crosslinking_Degree_Percent",
"value": "1.5",
"unit": "%",
"status": "PASS|WARNING|FAIL",
"message": "Rule-based check result"
},
{
"parameter": "Residual_BDDE_ppm",
"value": "1.2",
"unit": "ppm",
"status": "PASS|WARNING|FAIL",
"message": "Rule-based check result"
},
{
"parameter": "Particle_Size_um",
"value": "250.0",
"unit": "µm",
"status": "PASS|WARNING|FAIL",
"message": "Rule-based check result"
},
{
"parameter": "Viscosity_Pa_s",
"value": "25.0",
"unit": "as specified",
"status": "PASS|WARNING|FAIL",
"message": "Rule-based check result"
},
{
"parameter": "G_Prime_Pa",
"value": "450.0",
"unit": "as specified",
"status": "PASS|WARNING|FAIL",
"message": "Rule-based check result"
},
{
"parameter": "G_DoublePrime_Pa",
"value": "150.0",
"unit": "as specified",
"status": "PASS|WARNING|FAIL",
"message": "Rule-based check result"
}
],
"criticalFindings": [],
"sourceFile": "input.csv"
}9. OQ/PQ test scenarios
| ID | Scenario | Expected result |
|---|---|---|
| TC-001 | Valid CSV with expected header and sample row | All rows are processed; output contains PASS/WARNING/FAIL and parameter-level detail. |
| TC-002 | A mandatory input.csv column is missing | Import is rejected or the row receives FAIL with schema reference. |
| TC-003 | A numeric field contains text or a blank value | Type conversion error is recorded; the result is not hidden as PASS. |
| TC-004 | A parameter is outside specification or critical limit | Critical parameters produce FAIL; non-critical deviations produce WARNING according to the rule. |
| TC-005 | Positive pathogen/microbiological flag or microbiological limit excursion | Critical FAIL is produced with the offending parameter. |
10. QA/QC, CSV and change control
- Before production use, the client records executable version, checksum, specification/monograph version, test CSV, expected JSON and IQ/OQ results.
- Column names must not be changed without updating the validator and test scenarios.
- The source CSV, output.json and utility version should be stored together as an evidence package.
- Any change in control rules must go through change control and repeated OQ scenario verification.
Included in packages
Dermal Fillers QC Suite
Package for injectable implants and dermal fillers: hyaluronic acid, CaHA, PLLA, PMMA, collagen and related tests.
Open