HemodialysisSolutionQualityChecker

Hemodialysis Solution

contrast media dialysis endotoxins infusions sterile products WFI
Open selection

Hemodialysis Solution Quality Checker — Hemodialysis fluid quality assessment (Ph. Eur. 0424)

ℹ️ The utility verifies that electrolyte composition, endotoxins, and pH of hemodialysis fluids comply with European Pharmacopoeia requirements.
ℹ️ Does not use machine learning — rule-based logic only.
⚠️ Electrolyte accuracy is critical for maintaining patient acid-base balance.

Usage:
HemodialysisSolutionQualityChecker.exe → demo mode (console output)
HemodialysisSolutionQualityChecker.exe input.csv output.json → evaluate your data

Input format:
ProductName,BatchNumber,Sodium_mmol_per_L,Potassium_mmol_per_L,Calcium_mmol_per_L,Magnesium_mmol_per_L,Chloride_mmol_per_L,Acetate_mmol_per_L,Bicarbonate_mmol_per_L,Glucose_mmol_per_L,EndotoxinLevel_EU_per_ml,pH

Example:
HemodialysisSolution_Standard,HD20260301,138.0,2.0,1.5,0.5,109.5,3.0,35.0,5.5,0.1,7.3

— WHY IS THIS NEEDED?
Hemodialysis fluids directly contact patient blood. Their composition must match physiological parameters:
• Electrolyte deviation → electrolyte imbalance, arrhythmias,
• High endotoxins → inflammatory response,
• Incorrect pH → metabolic acidosis/alkalosis.
Compliance with Ph. Eur. 0424 is mandatory for dialysate release.

input.csv

ProductName,BatchNumber,Sodium_mmol_per_L,Potassium_mmol_per_L,Calcium_mmol_per_L,Magnesium_mmol_per_L,Chloride_mmol_per_L,Acetate_mmol_per_L,Bicarbonate_mmol_per_L,Glucose_mmol_per_L,EndotoxinLevel_EU_per_ml,pH
HemodialysisSolution_Standard,HD20260301,138.0,2.0,1.5,0.5,109.5,3.0,35.0,5.5,0.1,7.3

URS & FS — user requirements and functional specification

This document defines user requirements and functional specification for the quality-control utility. It supports deployment discussion, IQ/OQ preparation and QC workflow integration.

Utility: HemodialysisSolutionQualityCheckerAPI / object: Hemodialysis SolutionCategory: Sterile liquids

1. Scope

The Hemodialysis Solution Quality Checker utility is used for Hemodialysis Solution. The actual input.csv is the source of truth for the input structure; control criteria are defined by the executable and the domain description.

The utility does not use machine learning; decisions are produced by deterministic rules.

Categories: Sterile liquids

Tags: contrast media, dialysis, endotoxins, infusions, sterile products, WFI

2. Execution modes

HemodialysisSolutionQualityChecker.exe                            → demo mode (console output)
HemodialysisSolutionQualityChecker.exe input.csv output.json      → evaluate your data

3. Key controlled areas

  • microbiology and pathogens
  • pH and physicochemical parameters

4. Domain limits and critical parameters

  • ⚠️ Electrolyte accuracy is critical for maintaining patient acid-base balance.
Limits stated in the description must be verified against the current approved specification, pharmacopoeial monograph and registration dossier before production use.

5. URS — user requirements

IDRequirementCriticalityAcceptance criterion
URS-001The system shall accept an input.csv file for Hemodialysis Solution with the exact columns listed in the “Input data contract” section.HighA file with the correct header is processed without manual editing; missing mandatory columns produce FAIL/import error.
URS-002The system shall support execution without arguments in demo mode and execution with input.csv output.json for user data.MediumBoth execution scenarios produce a predictable result or clear diagnostic error.
URS-003The system shall perform rule-based controls for: microbiology and pathogens, pH and physicochemical parameters.HighEach controlled parameter receives a status and message; the result does not depend on hidden Excel formulas or ML.
URS-004The system shall preserve traceability between batch/lot, source values, applied rules and final verdict.HighOutput includes batch identifier, source values, parameter statuses and critical findings.
URS-005The system shall generate machine-readable output.json for LIMS/ELN/MES, batch record and QA/QC review.HighJSON contains overall status, check array, warnings, failures and source-file reference.
URS-006The system shall support use in the client validation package: URS/FS, IQ/OQ preparation, installation and operational scenario checks.HighThe document, test scenarios and reproducible CSV/JSON flow are suitable for audit and internal approval.
URS-007The system shall clearly separate technical data errors from specification nonconformities.MediumSchema/type errors are not mixed with pharmacopoeial deviations and are reported separately.

6. input.csv data contract

The source of truth for the input schema is the actual input.csv header. Column names are technical identifiers and are not translated.

#ColumnTypeUnitDescriptionSampleControl rule
1ProductNameidentifieras specifiedProduct NameHemodialysisSolution_Standardmandatory value; format and acceptability are checked by the utility
2BatchNumberidentifieras specifiedBatch NumberHD20260301mandatory field; used for batch/lot traceability
3Sodium_mmol_per_Ldecimalas specifiedSodium mmol per L138.0mandatory numeric value; rule comparison is performed by the utility
4Potassium_mmol_per_Ldecimalas specifiedPotassium mmol per L2.0mandatory numeric value; rule comparison is performed by the utility
5Calcium_mmol_per_Ldecimalas specifiedCalcium mmol per L1.5mandatory numeric value; rule comparison is performed by the utility
6Magnesium_mmol_per_Ldecimalas specifiedMagnesium mmol per L0.5mandatory numeric value; rule comparison is performed by the utility
7Chloride_mmol_per_Ldecimalas specifiedChloride mmol per L109.5mandatory numeric value; rule comparison is performed by the utility
8Acetate_mmol_per_Ldecimalas specifiedAcetate mmol per L3.0mandatory numeric value; rule comparison is performed by the utility
9Bicarbonate_mmol_per_Ldecimalas specifiedBicarbonate mmol per L35.0mandatory numeric value; rule comparison is performed by the utility
10Glucose_mmol_per_Ldecimalas specifiedGlucose mmol per L5.5mandatory numeric value; rule comparison is performed by the utility
11EndotoxinLevel_EU_per_mldecimalEU/mlEndotoxin Level EU per ml0.1numeric value; critical safety attribute compared with endotoxin limit
12pHdecimalpHp H7.3mandatory numeric value; rule comparison is performed by the utility

CSV example

ProductName,BatchNumber,Sodium_mmol_per_L,Potassium_mmol_per_L,Calcium_mmol_per_L,Magnesium_mmol_per_L,Chloride_mmol_per_L,Acetate_mmol_per_L,Bicarbonate_mmol_per_L,Glucose_mmol_per_L,EndotoxinLevel_EU_per_ml,pH
HemodialysisSolution_Standard,HD20260301,138.0,2.0,1.5,0.5,109.5,3.0,35.0,5.5,0.1,7.3

7. FS — functional specification

IDFunctionImplementation description
FS-001CLI entry pointThe executable HemodialysisSolutionQualityChecker.exe supports demo mode and input.csv output.json processing mode.
FS-002CSV parserThe import module reads CSV, validates header, column presence/order, value count and encoding. Decimal values are expected with a dot separator.
FS-003Field conversionEach column is converted to the expected type: identifier, text, decimal number, date/time or boolean flag.
FS-004Domain rule engineFor Hemodialysis Solution, explicit rules are applied: range, minimum, maximum, absence of prohibited flag, data completeness or calculation-based check.
FS-005Criticality handlingCritical violations produce FAIL; non-critical deviations and incomplete data produce WARNING; full conformance produces PASS.
FS-006JSON writeroutput.json stores overall status, per-parameter results, source values, warnings, failures and diagnostic messages.
FS-007Integration contractThe CSV → JSON format is stable for invocation from LIMS/ELN/MES, scheduled task or wrapper service.
FS-008Error handlingSchema error, missing file, non-numeric value or JSON write failure returns diagnosable error without silent PASS.

8. output.json contract

The output file must be suitable for automated processing, audit review and correlation with the source input.csv row.

{
  "utility": "HemodialysisSolutionQualityChecker",
  "api": "Hemodialysis Solution",
  "batchNumber": "HD20260301",
  "overallStatus": "PASS|WARNING|FAIL",
  "checkedAtUtc": "2026-05-18T00:00:00Z",
  "checks": [
    {
      "parameter": "ProductName",
      "value": "HemodialysisSolution_Standard",
      "unit": "as specified",
      "status": "PASS|WARNING|FAIL",
      "message": "Rule-based check result"
    },
    {
      "parameter": "BatchNumber",
      "value": "HD20260301",
      "unit": "as specified",
      "status": "PASS|WARNING|FAIL",
      "message": "Rule-based check result"
    },
    {
      "parameter": "Sodium_mmol_per_L",
      "value": "138.0",
      "unit": "as specified",
      "status": "PASS|WARNING|FAIL",
      "message": "Rule-based check result"
    },
    {
      "parameter": "Potassium_mmol_per_L",
      "value": "2.0",
      "unit": "as specified",
      "status": "PASS|WARNING|FAIL",
      "message": "Rule-based check result"
    },
    {
      "parameter": "Calcium_mmol_per_L",
      "value": "1.5",
      "unit": "as specified",
      "status": "PASS|WARNING|FAIL",
      "message": "Rule-based check result"
    },
    {
      "parameter": "Magnesium_mmol_per_L",
      "value": "0.5",
      "unit": "as specified",
      "status": "PASS|WARNING|FAIL",
      "message": "Rule-based check result"
    },
    {
      "parameter": "Chloride_mmol_per_L",
      "value": "109.5",
      "unit": "as specified",
      "status": "PASS|WARNING|FAIL",
      "message": "Rule-based check result"
    },
    {
      "parameter": "Acetate_mmol_per_L",
      "value": "3.0",
      "unit": "as specified",
      "status": "PASS|WARNING|FAIL",
      "message": "Rule-based check result"
    }
  ],
  "criticalFindings": [],
  "sourceFile": "input.csv"
}

9. OQ/PQ test scenarios

IDScenarioExpected result
TC-001Valid CSV with expected header and sample rowAll rows are processed; output contains PASS/WARNING/FAIL and parameter-level detail.
TC-002A mandatory input.csv column is missingImport is rejected or the row receives FAIL with schema reference.
TC-003A numeric field contains text or a blank valueType conversion error is recorded; the result is not hidden as PASS.
TC-004A parameter is outside specification or critical limitCritical parameters produce FAIL; non-critical deviations produce WARNING according to the rule.
TC-005Positive pathogen/microbiological flag or microbiological limit excursionCritical FAIL is produced with the offending parameter.

10. QA/QC, CSV and change control

  • Before production use, the client records executable version, checksum, specification/monograph version, test CSV, expected JSON and IQ/OQ results.
  • Column names must not be changed without updating the validator and test scenarios.
  • The source CSV, output.json and utility version should be stored together as an evidence package.
  • Any change in control rules must go through change control and repeated OQ scenario verification.

Included in packages

Diabetes QC Suite

QC package for diabetes medicines: insulins, metformin, SGLT2/DPP-4/GLP-1 products, glucagon and supporting dosage-form quality checks.

Open

Medical Liquids QC Suite

Package for sterile liquids, infusion solutions, dialysis solutions, contrast media and water for injections.

Open

Radiology QC Suite

QC package for radiology and diagnostic imaging: radiopharmaceuticals, PET/SPECT, contrast media, iodinated and gadolinium products, plus particle, sterility and endotoxin checks.

Open