DesogestrelQualityChecker
Desogestrel
Desogestrel Quality Checker — Desogestrel (Progestogen for Mini-Pills and Implants) (Ph. Eur. 2.8.1)
ℹ️ The utility checks assay, specific rotation, melting point, UV ratio, impurities (3-keto and epi-isomers), residual solvents.
ℹ️ Does not use machine learning — rule-based logic only.
⚠️ Critical for mini-pill production (Cerazette), combined COCs (Novinet, Mercilon), subdermal implants. Strict impurity control is mandatory!
Usage:
DesogestrelQualityChecker.exe → demo mode (console output)
DesogestrelQualityChecker.exe input.csv output.json → evaluate your data
Input format:
BatchNumber,AssayPercent,SpecificRotation,MeltingPoint,UV240_280,Impurity3Keto,ImpurityEpi,TotalImpurities,LossOnDrying,HeavyMetals,ResidualSolvents,EthanolPPM,AcetonePPM,ClarityNTU,ColorAPHA
Example:
DES-2026-001,99.5,30.0,187.5,2.0,0.2,0.1,0.4,0.3,5,1500,800,500,2,30
— WHY IS THIS NEEDED?
Desogestrel — third-generation synthetic progestogen critical for:
• Mini-pills (Cerazette) — progestogen-only, suitable for breastfeeding women
• Combined COCs (Novinet, Mercilon, Jeanine) — with ethinylestradiol
• Subdermal implants (Implanon, Nexplanon) — long-acting (3 years)
⚠️ CRITICAL:
• 3-Keto-desogestrel — main degradation impurity, reduces progestogenic activity
• Epi-desogestrel — stereoisomer, affects pharmacokinetics
• Specific rotation and UV ratio — key identification and purity parameters
• Melting point — confirms crystalline structure
Critical parameters:
• Assay 97.0–103.0% (on dried basis)
• Specific rotation +28.0° to +32.0° (in chloroform — key identification parameter)
• Melting point 185.0–190.0°C (identification and purity)
• UV ratio A240/A280: 1.8–2.2 (maximum at 240 nm — structure confirmation)
• 3-Keto-desogestrel ≤0.5% (oxidation product — reduces activity!)
• Epi-desogestrel ≤0.5% (stereoisomer)
• Total impurities ≤1.0%
• Loss on drying ≤0.5%
• Heavy metals ≤10 ppm
• Residual solvents ≤5000 ppm (ethanol, acetone, etc.)
• Clarity ≤5 NTU, color ≤50 APHA (for 0.1% solution in methanol)
⚠️ Note: Desogestrel is sensitive to oxidation and light! Requires storage in light-protected packaging at temperature not exceeding 25°C. Analysis must be performed under light-protected conditions!
input.csv
BatchNumber,AssayPercent,SpecificRotation,MeltingPoint,UV240_280,Impurity3Keto,ImpurityEpi,TotalImpurities,LossOnDrying,HeavyMetals,ResidualSolvents,EthanolPPM,AcetonePPM,ClarityNTU,ColorAPHA DES-2026-001,99.5,30.0,187.5,2.0,0.2,0.1,0.4,0.3,5,1500,800,500,2,30
URS & FS — user requirements and functional specification
This document defines user requirements and functional specification for the quality-control utility. It supports deployment discussion, IQ/OQ preparation and QC workflow integration.
1. Scope
The Desogestrel Quality Checker utility is used for Desogestrel. The actual input.csv is the source of truth for the input structure; control criteria are defined by the executable and the domain description.
The utility does not use machine learning; decisions are produced by deterministic rules.
Categories: Contraceptives
Tags: assay, contraceptives, fixed-dose combinations, heavy metals, hormones, impurities, radiopharma, residual solvents
2. Execution modes
DesogestrelQualityChecker.exe → demo mode (console output) DesogestrelQualityChecker.exe input.csv output.json → evaluate your data
3. Key controlled areas
- assay / content
- purity and impurities
- residual solvents
- heavy metals / elemental impurities
- pH and physicochemical parameters
4. Domain limits and critical parameters
- ⚠️ Critical for mini-pill production (Cerazette), combined COCs (Novinet, Mercilon), subdermal implants. Strict impurity control is mandatory!
- ⚠️ CRITICAL:
- 3-Keto-desogestrel — main degradation impurity, reduces progestogenic activity
- Epi-desogestrel — stereoisomer, affects pharmacokinetics
- Specific rotation and UV ratio — key identification and purity parameters
- Melting point — confirms crystalline structure
- Critical parameters:
- Assay 97.0–103.0% (on dried basis)
- Specific rotation +28.0° to +32.0° (in chloroform — key identification parameter)
- Melting point 185.0–190.0°C (identification and purity)
- UV ratio A240/A280: 1.8–2.2 (maximum at 240 nm — structure confirmation)
- 3-Keto-desogestrel ≤0.5% (oxidation product — reduces activity!)
- Epi-desogestrel ≤0.5% (stereoisomer)
- Total impurities ≤1.0%
- Loss on drying ≤0.5%
- Heavy metals ≤10 ppm
- Residual solvents ≤5000 ppm (ethanol, acetone, etc.)
- Clarity ≤5 NTU, color ≤50 APHA (for 0.1% solution in methanol)
- ⚠️ Note: Desogestrel is sensitive to oxidation and light! Requires storage in light-protected packaging at temperature not exceeding 25°C. Analysis must be performed under light-protected conditions!
5. URS — user requirements
| ID | Requirement | Criticality | Acceptance criterion |
|---|---|---|---|
| URS-001 | The system shall accept an input.csv file for Desogestrel with the exact columns listed in the “Input data contract” section. | High | A file with the correct header is processed without manual editing; missing mandatory columns produce FAIL/import error. |
| URS-002 | The system shall support execution without arguments in demo mode and execution with input.csv output.json for user data. | Medium | Both execution scenarios produce a predictable result or clear diagnostic error. |
| URS-003 | The system shall perform rule-based controls for: assay / content, purity and impurities, residual solvents, heavy metals / elemental impurities, pH and physicochemical parameters. | High | Each controlled parameter receives a status and message; the result does not depend on hidden Excel formulas or ML. |
| URS-004 | The system shall preserve traceability between batch/lot, source values, applied rules and final verdict. | High | Output includes batch identifier, source values, parameter statuses and critical findings. |
| URS-005 | The system shall generate machine-readable output.json for LIMS/ELN/MES, batch record and QA/QC review. | High | JSON contains overall status, check array, warnings, failures and source-file reference. |
| URS-006 | The system shall support use in the client validation package: URS/FS, IQ/OQ preparation, installation and operational scenario checks. | High | The document, test scenarios and reproducible CSV/JSON flow are suitable for audit and internal approval. |
| URS-007 | The system shall clearly separate technical data errors from specification nonconformities. | Medium | Schema/type errors are not mixed with pharmacopoeial deviations and are reported separately. |
6. input.csv data contract
The source of truth for the input schema is the actual input.csv header. Column names are technical identifiers and are not translated.
| # | Column | Type | Unit | Description | Sample | Control rule |
|---|---|---|---|---|---|---|
| 1 | BatchNumber | identifier | as specified | Batch Number | DES-2026-001 | mandatory field; used for batch/lot traceability |
| 2 | AssayPercent | decimal | % | Assay % | 99.5 | numeric value; compared with assay/purity limit from specification or method |
| 3 | SpecificRotation | decimal | as specified | Specific Rotation | 30.0 | mandatory numeric value; rule comparison is performed by the utility |
| 4 | MeltingPoint | decimal | °C | Melting Point | 187.5 | mandatory numeric value; rule comparison is performed by the utility |
| 5 | UV240_280 | decimal | as specified | UV240 280 | 2.0 | mandatory numeric value; rule comparison is performed by the utility |
| 6 | Impurity3Keto | decimal | as specified | Impurity3 Keto | 0.2 | numeric value; compared with individual or total impurity limit |
| 7 | ImpurityEpi | decimal | as specified | Impurity Epi | 0.1 | numeric value; compared with individual or total impurity limit |
| 8 | TotalImpurities | decimal | as specified | Total Impurities | 0.4 | mandatory numeric value; rule comparison is performed by the utility |
| 9 | LossOnDrying | decimal | as specified | Loss On Drying | 0.3 | mandatory numeric value; rule comparison is performed by the utility |
| 10 | HeavyMetals | decimal | as specified | Heavy Metals | 5 | numeric value; checked as elemental/metal impurity |
| 11 | ResidualSolvents | decimal | as specified | Residual Solvents | 1500 | numeric value; checked as residual solvent against the applicable limit |
| 12 | EthanolPPM | decimal | ppm | Ethanol PPM | 800 | numeric value; checked as residual solvent against the applicable limit |
| 13 | AcetonePPM | decimal | ppm | Acetone PPM | 500 | numeric value; checked as residual solvent against the applicable limit |
| 14 | ClarityNTU | decimal | as specified | Clarity NTU | 2 | mandatory numeric value; rule comparison is performed by the utility |
| 15 | ColorAPHA | decimal | as specified | Color APHA | 30 | mandatory numeric value; rule comparison is performed by the utility |
CSV example
BatchNumber,AssayPercent,SpecificRotation,MeltingPoint,UV240_280,Impurity3Keto,ImpurityEpi,TotalImpurities,LossOnDrying,HeavyMetals,ResidualSolvents,EthanolPPM,AcetonePPM,ClarityNTU,ColorAPHA DES-2026-001,99.5,30.0,187.5,2.0,0.2,0.1,0.4,0.3,5,1500,800,500,2,30
7. FS — functional specification
| ID | Function | Implementation description |
|---|---|---|
| FS-001 | CLI entry point | The executable DesogestrelQualityChecker.exe supports demo mode and input.csv output.json processing mode. |
| FS-002 | CSV parser | The import module reads CSV, validates header, column presence/order, value count and encoding. Decimal values are expected with a dot separator. |
| FS-003 | Field conversion | Each column is converted to the expected type: identifier, text, decimal number, date/time or boolean flag. |
| FS-004 | Domain rule engine | For Desogestrel, explicit rules are applied: range, minimum, maximum, absence of prohibited flag, data completeness or calculation-based check. |
| FS-005 | Criticality handling | Critical violations produce FAIL; non-critical deviations and incomplete data produce WARNING; full conformance produces PASS. |
| FS-006 | JSON writer | output.json stores overall status, per-parameter results, source values, warnings, failures and diagnostic messages. |
| FS-007 | Integration contract | The CSV → JSON format is stable for invocation from LIMS/ELN/MES, scheduled task or wrapper service. |
| FS-008 | Error handling | Schema error, missing file, non-numeric value or JSON write failure returns diagnosable error without silent PASS. |
8. output.json contract
The output file must be suitable for automated processing, audit review and correlation with the source input.csv row.
{
"utility": "DesogestrelQualityChecker",
"api": "Desogestrel",
"batchNumber": "DES-2026-001",
"overallStatus": "PASS|WARNING|FAIL",
"checkedAtUtc": "2026-05-18T00:00:00Z",
"checks": [
{
"parameter": "BatchNumber",
"value": "DES-2026-001",
"unit": "as specified",
"status": "PASS|WARNING|FAIL",
"message": "Rule-based check result"
},
{
"parameter": "AssayPercent",
"value": "99.5",
"unit": "%",
"status": "PASS|WARNING|FAIL",
"message": "Rule-based check result"
},
{
"parameter": "SpecificRotation",
"value": "30.0",
"unit": "as specified",
"status": "PASS|WARNING|FAIL",
"message": "Rule-based check result"
},
{
"parameter": "MeltingPoint",
"value": "187.5",
"unit": "°C",
"status": "PASS|WARNING|FAIL",
"message": "Rule-based check result"
},
{
"parameter": "UV240_280",
"value": "2.0",
"unit": "as specified",
"status": "PASS|WARNING|FAIL",
"message": "Rule-based check result"
},
{
"parameter": "Impurity3Keto",
"value": "0.2",
"unit": "as specified",
"status": "PASS|WARNING|FAIL",
"message": "Rule-based check result"
},
{
"parameter": "ImpurityEpi",
"value": "0.1",
"unit": "as specified",
"status": "PASS|WARNING|FAIL",
"message": "Rule-based check result"
},
{
"parameter": "TotalImpurities",
"value": "0.4",
"unit": "as specified",
"status": "PASS|WARNING|FAIL",
"message": "Rule-based check result"
}
],
"criticalFindings": [],
"sourceFile": "input.csv"
}9. OQ/PQ test scenarios
| ID | Scenario | Expected result |
|---|---|---|
| TC-001 | Valid CSV with expected header and sample row | All rows are processed; output contains PASS/WARNING/FAIL and parameter-level detail. |
| TC-002 | A mandatory input.csv column is missing | Import is rejected or the row receives FAIL with schema reference. |
| TC-003 | A numeric field contains text or a blank value | Type conversion error is recorded; the result is not hidden as PASS. |
| TC-004 | A parameter is outside specification or critical limit | Critical parameters produce FAIL; non-critical deviations produce WARNING according to the rule. |
| TC-007 | Residual solvent above applicable limit | FAIL is produced with solvent name and measured value. |
10. QA/QC, CSV and change control
- Before production use, the client records executable version, checksum, specification/monograph version, test CSV, expected JSON and IQ/OQ results.
- Column names must not be changed without updating the validator and test scenarios.
- The source CSV, output.json and utility version should be stored together as an evidence package.
- Any change in control rules must go through change control and repeated OQ scenario verification.
Included in packages
Contraceptives QC Suite
Quality-control package for contraceptives: hormonal APIs, fixed combinations, implants, rings and intrauterine systems.
OpenEndocrinology QC Suite
QC package for endocrinology: thyroid, pituitary/peptide hormones, corticosteroids, sex hormones and selected metabolic medicines.
OpenGynecology QC Suite
QC package for gynecology: hormones, contraceptives, uterotonics, anti-infectives and women’s-health medicines.
OpenRadiology QC Suite
QC package for radiology and diagnostic imaging: radiopharmaceuticals, PET/SPECT, contrast media, iodinated and gadolinium products, plus particle, sterility and endotoxin checks.
Open