Compressed Air Pharmaceutical Quality Checker — Medical compressed air quality assessment (Ph. Eur. 0422)

ℹ️  Verifies compliance with European and US Pharmacopoeia.
⚠️  Critical limits: oil ≤0.01 mg/m³, dew point ≤ -40°C, TAMC ≤10 CFU/m³, TYMC = 0.

Usage:
  CompressedAirPharmaceuticalQualityChecker.exe                            → demo mode
  CompressedAirPharmaceuticalQualityChecker.exe input.csv output.json      → evaluate data

Input format:
ProductName,BatchNumber,Oxygen_percent,OilContent_mg_per_m3,WaterDewPoint_C,CarbonMonoxide_ppm,CarbonDioxide_ppm,TAMC_CFU_per_m3,TYMC_CFU_per_m3,Appearance

Example:
Compressed_Air_Medical,AIR20250305,20.9,0.005,-45,0.1,300,3,0,"ColorlessOdorlessGas"

— WHY IS THIS NEEDED?
Medical compressed air is a medicinal product delivered directly to patients. Oil causes lipoid pneumonia, moisture promotes corrosion and microbial growth, CO is toxic. Microbial contamination is unacceptable in prolonged therapy.
Compliance with Ph. Eur. 0422 and USP <1> is mandatory for batch release.

input.csv

ProductName,BatchNumber,Oxygen_percent,OilContent_mg_per_m3,WaterDewPoint_C,CarbonMonoxide_ppm,CarbonDioxide_ppm,TAMC_CFU_per_m3,TYMC_CFU_per_m3,Appearance
Compressed_Air_Medical,AIR20250305,20.9,0.005,-45,0.1,300,3,0,"ColorlessOdorlessGas"

URS & FS — user requirements and functional specification

This document defines user requirements and functional specification for the quality-control utility. It supports deployment discussion, IQ/OQ preparation and QC workflow integration.

Utility: CompressedAirPharmaceuticalQualityCheckerAPI / object: Compressed Air PharmaceuticalCategory: Medical gases

1. Scope

The Compressed Air Pharmaceutical Quality Checker utility is used for Compressed Air Pharmaceutical. The actual input.csv is the source of truth for the input structure; control criteria are defined by the executable and the domain description.

The utility does not use machine learning; decisions are produced by deterministic rules.

Categories: Medical gases

Tags: carbon dioxide, impurities, medical gases, microbiology, nitrogen, oxygen, specification, water quality

2. Execution modes

CompressedAirPharmaceuticalQualityChecker.exe                            → demo mode
CompressedAirPharmaceuticalQualityChecker.exe input.csv output.json      → evaluate data

3. Key controlled areas

  • assay / content
  • microbiology and pathogens

4. Domain limits and critical parameters

  • ⚠️ Critical limits: oil ≤0.01 mg/m³, dew point ≤ -40°C, TAMC ≤10 CFU/m³, TYMC = 0.
Limits stated in the description must be verified against the current approved specification, pharmacopoeial monograph and registration dossier before production use.

5. URS — user requirements

IDRequirementCriticalityAcceptance criterion
URS-001The system shall accept an input.csv file for Compressed Air Pharmaceutical with the exact columns listed in the “Input data contract” section.HighA file with the correct header is processed without manual editing; missing mandatory columns produce FAIL/import error.
URS-002The system shall support execution without arguments in demo mode and execution with input.csv output.json for user data.MediumBoth execution scenarios produce a predictable result or clear diagnostic error.
URS-003The system shall perform rule-based controls for: assay / content, microbiology and pathogens.HighEach controlled parameter receives a status and message; the result does not depend on hidden Excel formulas or ML.
URS-004The system shall preserve traceability between batch/lot, source values, applied rules and final verdict.HighOutput includes batch identifier, source values, parameter statuses and critical findings.
URS-005The system shall generate machine-readable output.json for LIMS/ELN/MES, batch record and QA/QC review.HighJSON contains overall status, check array, warnings, failures and source-file reference.
URS-006The system shall support use in the client validation package: URS/FS, IQ/OQ preparation, installation and operational scenario checks.HighThe document, test scenarios and reproducible CSV/JSON flow are suitable for audit and internal approval.
URS-007The system shall clearly separate technical data errors from specification nonconformities.MediumSchema/type errors are not mixed with pharmacopoeial deviations and are reported separately.

6. input.csv data contract

The source of truth for the input schema is the actual input.csv header. Column names are technical identifiers and are not translated.

#ColumnTypeUnitDescriptionSampleControl rule
1ProductNameidentifieras specifiedProduct NameCompressed_Air_Medicalmandatory value; format and acceptability are checked by the utility
2BatchNumberidentifieras specifiedBatch NumberAIR20250305mandatory field; used for batch/lot traceability
3Oxygen_percentdecimal%Oxygen percent20.9mandatory numeric value; rule comparison is performed by the utility
4OilContent_mg_per_m3decimalas specifiedOil Content mg per m30.005numeric value; compared with assay/purity limit from specification or method
5WaterDewPoint_Cdecimalas specifiedWater Dew Point C-45mandatory numeric value; rule comparison is performed by the utility
6CarbonMonoxide_ppmdecimalppmCarbon Monoxide ppm0.1mandatory numeric value; rule comparison is performed by the utility
7CarbonDioxide_ppmdecimalppmCarbon Dioxide ppm300mandatory numeric value; rule comparison is performed by the utility
8TAMC_CFU_per_m3decimalCFUTAMC CFU per m33numeric value; compared with microbiological limits
9TYMC_CFU_per_m3decimalCFUTYMC CFU per m30numeric value; compared with microbiological limits
10Appearancetextas specifiedAppearanceColorlessOdorlessGasmandatory value; format and acceptability are checked by the utility

CSV example

ProductName,BatchNumber,Oxygen_percent,OilContent_mg_per_m3,WaterDewPoint_C,CarbonMonoxide_ppm,CarbonDioxide_ppm,TAMC_CFU_per_m3,TYMC_CFU_per_m3,Appearance
Compressed_Air_Medical,AIR20250305,20.9,0.005,-45,0.1,300,3,0,"ColorlessOdorlessGas"

7. FS — functional specification

IDFunctionImplementation description
FS-001CLI entry pointThe executable CompressedAirPharmaceuticalQualityChecker.exe supports demo mode and input.csv output.json processing mode.
FS-002CSV parserThe import module reads CSV, validates header, column presence/order, value count and encoding. Decimal values are expected with a dot separator.
FS-003Field conversionEach column is converted to the expected type: identifier, text, decimal number, date/time or boolean flag.
FS-004Domain rule engineFor Compressed Air Pharmaceutical, explicit rules are applied: range, minimum, maximum, absence of prohibited flag, data completeness or calculation-based check.
FS-005Criticality handlingCritical violations produce FAIL; non-critical deviations and incomplete data produce WARNING; full conformance produces PASS.
FS-006JSON writeroutput.json stores overall status, per-parameter results, source values, warnings, failures and diagnostic messages.
FS-007Integration contractThe CSV → JSON format is stable for invocation from LIMS/ELN/MES, scheduled task or wrapper service.
FS-008Error handlingSchema error, missing file, non-numeric value or JSON write failure returns diagnosable error without silent PASS.

8. output.json contract

The output file must be suitable for automated processing, audit review and correlation with the source input.csv row.

{
  "utility": "CompressedAirPharmaceuticalQualityChecker",
  "api": "Compressed Air Pharmaceutical",
  "batchNumber": "AIR20250305",
  "overallStatus": "PASS|WARNING|FAIL",
  "checkedAtUtc": "2026-05-18T00:00:00Z",
  "checks": [
    {
      "parameter": "ProductName",
      "value": "Compressed_Air_Medical",
      "unit": "as specified",
      "status": "PASS|WARNING|FAIL",
      "message": "Rule-based check result"
    },
    {
      "parameter": "BatchNumber",
      "value": "AIR20250305",
      "unit": "as specified",
      "status": "PASS|WARNING|FAIL",
      "message": "Rule-based check result"
    },
    {
      "parameter": "Oxygen_percent",
      "value": "20.9",
      "unit": "%",
      "status": "PASS|WARNING|FAIL",
      "message": "Rule-based check result"
    },
    {
      "parameter": "OilContent_mg_per_m3",
      "value": "0.005",
      "unit": "as specified",
      "status": "PASS|WARNING|FAIL",
      "message": "Rule-based check result"
    },
    {
      "parameter": "WaterDewPoint_C",
      "value": "-45",
      "unit": "as specified",
      "status": "PASS|WARNING|FAIL",
      "message": "Rule-based check result"
    },
    {
      "parameter": "CarbonMonoxide_ppm",
      "value": "0.1",
      "unit": "ppm",
      "status": "PASS|WARNING|FAIL",
      "message": "Rule-based check result"
    },
    {
      "parameter": "CarbonDioxide_ppm",
      "value": "300",
      "unit": "ppm",
      "status": "PASS|WARNING|FAIL",
      "message": "Rule-based check result"
    },
    {
      "parameter": "TAMC_CFU_per_m3",
      "value": "3",
      "unit": "CFU",
      "status": "PASS|WARNING|FAIL",
      "message": "Rule-based check result"
    }
  ],
  "criticalFindings": [],
  "sourceFile": "input.csv"
}

9. OQ/PQ test scenarios

IDScenarioExpected result
TC-001Valid CSV with expected header and sample rowAll rows are processed; output contains PASS/WARNING/FAIL and parameter-level detail.
TC-002A mandatory input.csv column is missingImport is rejected or the row receives FAIL with schema reference.
TC-003A numeric field contains text or a blank valueType conversion error is recorded; the result is not hidden as PASS.
TC-004A parameter is outside specification or critical limitCritical parameters produce FAIL; non-critical deviations produce WARNING according to the rule.
TC-005Positive pathogen/microbiological flag or microbiological limit excursionCritical FAIL is produced with the offending parameter.

10. QA/QC, CSV and change control

  • Before production use, the client records executable version, checksum, specification/monograph version, test CSV, expected JSON and IQ/OQ results.
  • Column names must not be changed without updating the validator and test scenarios.
  • The source CSV, output.json and utility version should be stored together as an evidence package.
  • Any change in control rules must go through change control and repeated OQ scenario verification.

Included in packages

Medical Gases QC Suite

Quality-control package for medical and pharmaceutical gases: oxygen, nitrogen, carbon dioxide, nitrous oxide, helium and mixtures.

Open