CCP_OPRP_ClassificationChecker_STD_ISO22000

CCP OPRP Classification Checker STD ISO22000

food-all food-safe food-iso-*-haccp CSV→JSON LabWare-compatible URS & FS rule-based
Open selection

Utility description: CCP OPRP Classification Checker STD ISO22000

CCP_OPRP_ClassificationChecker_STD_ISO22000 — Checks PRP, OPRP and CCP classification under ISO 22000

ℹ️  Intended use
A deterministic food-QC utility for food-safety management, hazard analysis and PRP/OPRP/CCP control. Each input.csv row is evaluated independently, and the rule logic is implemented directly in this product's Program.cs.

⚠️  Scope boundary
The utility performs screening/verification and does not replace the HACCP team, food-safety owner, laboratory specialist or legal applicability review. Before operational use, the site approves the product, matrix, method, sampling plan, limits and local SOP.

Regulatory or method basis:
ISO 22000:2018 food safety management systems; documented interpretation must be approved by the organization

URS / user requirements
• accept a fixed UTF-8 CSV contract
• produce a reproducible result without remote services or a hidden JSON rule schema
• return only PASS, FAIL or ERROR for each record
• create a LabWare-compatible output.json
• retain record identity, test name, analysis code, numeric results and review messages
• reject missing, malformed and logically impossible values explicitly

FS / functional behavior
• the business rule is unique to CCP_OPRP_ClassificationChecker_STD_ISO22000 and implemented in its Program.cs
• no arguments run the demonstration input.csv beside the EXE
• two arguments identify input.csv and output.json
• an internal WARNING screening result is exported as FAIL because the LIMS contract uses PASS/FAIL/ERROR
• an exception creates a Sample with Status=ERROR and StatusCode=-1

input.csv contract:
PlanId,ProcessStep,Hazard,ControlClassification,DecisionBasis,MeasurableLimit,MonitoringProcedure,Correction

Example:
FSMS-001,MetalDetection,Metal fragments,CCP,Loss of control may release unsafe product,Fe2.0mm|NonFe2.5mm|SS3.0mm,Hourly challenge test,Hold product since last satisfactory check

Usage:
  CCP_OPRP_ClassificationChecker_STD_ISO22000.exe
  CCP_OPRP_ClassificationChecker_STD_ISO22000.exe input.csv output.json

output.json contract
Header: UtilityName, Version, Timestamp, InstrumentID, OperatorID
Samples: SampleID, BatchNumber, ProductName, TestName, AnalysisCode, Status, StatusCode, ErrorMessage, Description, DescriptionEN, Results
Results: ParameterName, ResultValue, UnitOfMeasure, SpecificationLimit, IsWithinSpec

Verification
• the positive demonstration row shall return PASS
• the adverse row shall return FAIL
• malformed CSV or an invalid type shall return ERROR
• JSON shall deserialize against the Header/Samples/Results model
• site verification/PQ confirms actual limits, method, equipment and product disposition

Change control
Version 0.2.4. A change to market, source edition, allergen list, legal limit, method or decision rule requires review and a new utility version.

input.csv

PlanId,ProcessStep,Hazard,ControlClassification,DecisionBasis,MeasurableLimit,MonitoringProcedure,Correction
FSMS-001,MetalDetection,Metal fragments,CCP,Loss of control may release unsafe product,Fe2.0mm|NonFe2.5mm|SS3.0mm,Hourly challenge test,Hold product since last satisfactory check
FSMS-001,HandWashing,Microbial transfer,PRP,General hygiene programme,,,Retrain and restore supplies

URS & FS — user requirements and functional specification

URS — User Requirements Specification

• accept a fixed UTF-8 CSV contract
• produce a reproducible result without remote services or a hidden JSON rule schema
• return only PASS, FAIL or ERROR for each record
• create a LabWare-compatible output.json
• retain record identity, test name, analysis code, numeric results and review messages
• reject missing, malformed and logically impossible values explicitly

FS — Functional Specification

• the business rule is unique to CCP_OPRP_ClassificationChecker_STD_ISO22000 and implemented in its Program.cs
• no arguments run the demonstration input.csv beside the EXE
• two arguments identify input.csv and output.json
• an internal WARNING screening result is exported as FAIL because the LIMS contract uses PASS/FAIL/ERROR
• an exception creates a Sample with Status=ERROR and StatusCode=-1

input.csv contract:
PlanId,ProcessStep,Hazard,ControlClassification,DecisionBasis,MeasurableLimit,MonitoringProcedure,Correction

Example:
FSMS-001,MetalDetection,Metal fragments,CCP,Loss of control may release unsafe product,Fe2.0mm|NonFe2.5mm|SS3.0mm,Hourly challenge test,Hold product since last satisfactory check

Usage:
  CCP_OPRP_ClassificationChecker_STD_ISO22000.exe
  CCP_OPRP_ClassificationChecker_STD_ISO22000.exe input.csv output.json

output.json contract
Header: UtilityName, Version, Timestamp, InstrumentID, OperatorID
Samples: SampleID, BatchNumber, ProductName, TestName, AnalysisCode, Status, StatusCode, ErrorMessage, Description, DescriptionEN, Results
Results: ParameterName, ResultValue, UnitOfMeasure, SpecificationLimit, IsWithinSpec

Verification
• the positive demonstration row shall return PASS
• the adverse row shall return FAIL
• malformed CSV or an invalid type shall return ERROR
• JSON shall deserialize against the Header/Samples/Results model
• site verification/PQ confirms actual limits, method, equipment and product disposition

Change control
Version 0.2.4. A change to market, source edition, allergen list, legal limit, method or decision rule requires review and a new utility version.

Included in packages

Food — ISO 22000, HACCP and Food QC

35 deterministic utilities for ISO 22000/HACCP, food laboratories, labelling, process control, sanitation and traceability.

Open