ThiamineHydrochlorideQualityChecker

Thiamine Hydrochloride

assay heavy metals impurities medical gases minerals premix specification vitamins
Open selection

Thiamine Hydrochloride Quality Checker — Vitamin B1 (Ph. Eur. 2.8.1)

ℹ️ The utility checks assay, specific rotation, UV ratios, impurities (thiochrome — oxidation product), loss on drying, pH of solution.
ℹ️ Does not use machine learning — rule-based logic only.
⚠️ Critical for vitamin products, dietary supplements, parenteral nutrition, neuroprotective agents, alcoholism treatment preparations.

Usage:
ThiamineHydrochlorideQualityChecker.exe → demo mode (console output)
ThiamineHydrochlorideQualityChecker.exe input.csv output.json → evaluate your data

Input format:
BatchNumber,AssayPercent,SpecificRotation,UV246_267,UV246_230,Thiochrome,OtherImpurities,TotalImpurities,LossOnDrying,HeavyMetals,pH,ClarityNTU,ColorAPHA,EthanolPPM,AcetonePPM

Example:
B1-2026-001,99.5,25.2,0.47,0.42,0.05,0.3,0.6,0.7,12,3.0,2,35,800,500

— WHY IS THIS NEEDED?
Thiamine hydrochloride (vitamin B1) is a water-soluble vitamin critical for:
• Energy metabolism (coenzyme of pyruvate and α-ketoglutarate dehydrogenases)
• Nervous system function (neurotransmission, myelination)
• Prevention and treatment of beriberi, Wernicke-Korsakoff syndrome
• Vitamin complexes, dietary supplements, parenteral nutrition
• Preparations for alcoholism treatment and neurodegenerative diseases
⚠️ Extremely sensitive to oxidation! Thiochrome — fluorescent oxidation product, reduces activity. UV ratio control is critical for identification and purity!
Critical parameters:
• Assay 98.0–102.0% (on dried basis)
• Specific rotation +24.0° to +26.5° (in water — key identification parameter)
• UV maxima at 230, 246, 267 nm
• UV ratio A246/A267: 0.45–0.50 (identification and purity)
• UV ratio A246/A230: 0.40–0.45 (identification and purity)
• Thiochrome ≤0.1% (oxidation product — critical for stability and activity!)
• Total impurities ≤1.0%
• Loss on drying ≤1.0%
• Heavy metals ≤20 ppm
• pH of 2% solution: 2.5–3.5 (acidic reaction — characteristic of hydrochloride)
• Clarity ≤5 NTU, color ≤50 APHA
Monograph compliance is mandatory for registration. Requires protection from light, oxygen, and alkaline conditions during storage! Analysis must be performed in acidic medium (0.1M HCl) for stability.

input.csv

BatchNumber,AssayPercent,SpecificRotation,UV246_267,UV246_230,Thiochrome,OtherImpurities,TotalImpurities,LossOnDrying,HeavyMetals,pH,ClarityNTU,ColorAPHA,EthanolPPM,AcetonePPM
B1-2026-001,99.5,25.2,0.47,0.42,0.05,0.3,0.6,0.7,12,3.0,2,35,800,500

URS & FS — user requirements and functional specification

This document defines user requirements and functional specification for the quality-control utility. It supports deployment discussion, IQ/OQ preparation and QC workflow integration.

Utility: ThiamineHydrochlorideQualityCheckerAPI / object: Thiamine HydrochlorideCategory: Vitamins and minerals

1. Scope

The Thiamine Hydrochloride Quality Checker utility is used for Thiamine Hydrochloride. The actual input.csv is the source of truth for the input structure; control criteria are defined by the executable and the domain description.

The utility does not use machine learning; decisions are produced by deterministic rules.

Categories: Vitamins and minerals

Tags: assay, heavy metals, impurities, medical gases, minerals, premix, specification, vitamins, water quality

2. Execution modes

ThiamineHydrochlorideQualityChecker.exe                            → demo mode (console output)
ThiamineHydrochlorideQualityChecker.exe input.csv output.json      → evaluate your data

3. Key controlled areas

  • assay / content
  • residual solvents
  • heavy metals / elemental impurities
  • pH and physicochemical parameters

4. Domain limits and critical parameters

  • ⚠️ Critical for vitamin products, dietary supplements, parenteral nutrition, neuroprotective agents, alcoholism treatment preparations.
  • ⚠️ Extremely sensitive to oxidation! Thiochrome — fluorescent oxidation product, reduces activity. UV ratio control is critical for identification and purity!
  • Critical parameters:
  • Assay 98.0–102.0% (on dried basis)
  • Specific rotation +24.0° to +26.5° (in water — key identification parameter)
  • UV maxima at 230, 246, 267 nm
  • UV ratio A246/A267: 0.45–0.50 (identification and purity)
  • UV ratio A246/A230: 0.40–0.45 (identification and purity)
  • Thiochrome ≤0.1% (oxidation product — critical for stability and activity!)
  • Total impurities ≤1.0%
  • Loss on drying ≤1.0%
  • Heavy metals ≤20 ppm
  • pH of 2% solution: 2.5–3.5 (acidic reaction — characteristic of hydrochloride)
  • Clarity ≤5 NTU, color ≤50 APHA
  • Monograph compliance is mandatory for registration. Requires protection from light, oxygen, and alkaline conditions during storage! Analysis must be performed in acidic medium (0.1M HCl) for stability.
Limits stated in the description must be verified against the current approved specification, pharmacopoeial monograph and registration dossier before production use.

5. URS — user requirements

IDRequirementCriticalityAcceptance criterion
URS-001The system shall accept an input.csv file for Thiamine Hydrochloride with the exact columns listed in the “Input data contract” section.HighA file with the correct header is processed without manual editing; missing mandatory columns produce FAIL/import error.
URS-002The system shall support execution without arguments in demo mode and execution with input.csv output.json for user data.MediumBoth execution scenarios produce a predictable result or clear diagnostic error.
URS-003The system shall perform rule-based controls for: assay / content, residual solvents, heavy metals / elemental impurities, pH and physicochemical parameters.HighEach controlled parameter receives a status and message; the result does not depend on hidden Excel formulas or ML.
URS-004The system shall preserve traceability between batch/lot, source values, applied rules and final verdict.HighOutput includes batch identifier, source values, parameter statuses and critical findings.
URS-005The system shall generate machine-readable output.json for LIMS/ELN/MES, batch record and QA/QC review.HighJSON contains overall status, check array, warnings, failures and source-file reference.
URS-006The system shall support use in the client validation package: URS/FS, IQ/OQ preparation, installation and operational scenario checks.HighThe document, test scenarios and reproducible CSV/JSON flow are suitable for audit and internal approval.
URS-007The system shall clearly separate technical data errors from specification nonconformities.MediumSchema/type errors are not mixed with pharmacopoeial deviations and are reported separately.

6. input.csv data contract

The source of truth for the input schema is the actual input.csv header. Column names are technical identifiers and are not translated.

#ColumnTypeUnitDescriptionSampleControl rule
1BatchNumberidentifieras specifiedBatch NumberB1-2026-001mandatory field; used for batch/lot traceability
2AssayPercentdecimal%Assay %99.5numeric value; compared with assay/purity limit from specification or method
3SpecificRotationdecimalas specifiedSpecific Rotation25.2mandatory numeric value; rule comparison is performed by the utility
4UV246_267decimalas specifiedUV246 2670.47mandatory numeric value; rule comparison is performed by the utility
5UV246_230decimalas specifiedUV246 2300.42mandatory numeric value; rule comparison is performed by the utility
6Thiochromedecimalas specifiedThiochrome0.05mandatory numeric value; rule comparison is performed by the utility
7OtherImpuritiesdecimalas specifiedOther Impurities0.3mandatory numeric value; rule comparison is performed by the utility
8TotalImpuritiesdecimalas specifiedTotal Impurities0.6mandatory numeric value; rule comparison is performed by the utility
9LossOnDryingdecimalas specifiedLoss On Drying0.7mandatory numeric value; rule comparison is performed by the utility
10HeavyMetalsdecimalas specifiedHeavy Metals12numeric value; checked as elemental/metal impurity
11pHdecimalpHp H3.0mandatory numeric value; rule comparison is performed by the utility
12ClarityNTUdecimalas specifiedClarity NTU2mandatory numeric value; rule comparison is performed by the utility
13ColorAPHAdecimalas specifiedColor APHA35mandatory numeric value; rule comparison is performed by the utility
14EthanolPPMdecimalppmEthanol PPM800numeric value; checked as residual solvent against the applicable limit
15AcetonePPMdecimalppmAcetone PPM500numeric value; checked as residual solvent against the applicable limit

CSV example

BatchNumber,AssayPercent,SpecificRotation,UV246_267,UV246_230,Thiochrome,OtherImpurities,TotalImpurities,LossOnDrying,HeavyMetals,pH,ClarityNTU,ColorAPHA,EthanolPPM,AcetonePPM
B1-2026-001,99.5,25.2,0.47,0.42,0.05,0.3,0.6,0.7,12,3.0,2,35,800,500

7. FS — functional specification

IDFunctionImplementation description
FS-001CLI entry pointThe executable ThiamineHydrochlorideQualityChecker.exe supports demo mode and input.csv output.json processing mode.
FS-002CSV parserThe import module reads CSV, validates header, column presence/order, value count and encoding. Decimal values are expected with a dot separator.
FS-003Field conversionEach column is converted to the expected type: identifier, text, decimal number, date/time or boolean flag.
FS-004Domain rule engineFor Thiamine Hydrochloride, explicit rules are applied: range, minimum, maximum, absence of prohibited flag, data completeness or calculation-based check.
FS-005Criticality handlingCritical violations produce FAIL; non-critical deviations and incomplete data produce WARNING; full conformance produces PASS.
FS-006JSON writeroutput.json stores overall status, per-parameter results, source values, warnings, failures and diagnostic messages.
FS-007Integration contractThe CSV → JSON format is stable for invocation from LIMS/ELN/MES, scheduled task or wrapper service.
FS-008Error handlingSchema error, missing file, non-numeric value or JSON write failure returns diagnosable error without silent PASS.

8. output.json contract

The output file must be suitable for automated processing, audit review and correlation with the source input.csv row.

{
  "utility": "ThiamineHydrochlorideQualityChecker",
  "api": "Thiamine Hydrochloride",
  "batchNumber": "B1-2026-001",
  "overallStatus": "PASS|WARNING|FAIL",
  "checkedAtUtc": "2026-05-18T00:00:00Z",
  "checks": [
    {
      "parameter": "BatchNumber",
      "value": "B1-2026-001",
      "unit": "as specified",
      "status": "PASS|WARNING|FAIL",
      "message": "Rule-based check result"
    },
    {
      "parameter": "AssayPercent",
      "value": "99.5",
      "unit": "%",
      "status": "PASS|WARNING|FAIL",
      "message": "Rule-based check result"
    },
    {
      "parameter": "SpecificRotation",
      "value": "25.2",
      "unit": "as specified",
      "status": "PASS|WARNING|FAIL",
      "message": "Rule-based check result"
    },
    {
      "parameter": "UV246_267",
      "value": "0.47",
      "unit": "as specified",
      "status": "PASS|WARNING|FAIL",
      "message": "Rule-based check result"
    },
    {
      "parameter": "UV246_230",
      "value": "0.42",
      "unit": "as specified",
      "status": "PASS|WARNING|FAIL",
      "message": "Rule-based check result"
    },
    {
      "parameter": "Thiochrome",
      "value": "0.05",
      "unit": "as specified",
      "status": "PASS|WARNING|FAIL",
      "message": "Rule-based check result"
    },
    {
      "parameter": "OtherImpurities",
      "value": "0.3",
      "unit": "as specified",
      "status": "PASS|WARNING|FAIL",
      "message": "Rule-based check result"
    },
    {
      "parameter": "TotalImpurities",
      "value": "0.6",
      "unit": "as specified",
      "status": "PASS|WARNING|FAIL",
      "message": "Rule-based check result"
    }
  ],
  "criticalFindings": [],
  "sourceFile": "input.csv"
}

9. OQ/PQ test scenarios

IDScenarioExpected result
TC-001Valid CSV with expected header and sample rowAll rows are processed; output contains PASS/WARNING/FAIL and parameter-level detail.
TC-002A mandatory input.csv column is missingImport is rejected or the row receives FAIL with schema reference.
TC-003A numeric field contains text or a blank valueType conversion error is recorded; the result is not hidden as PASS.
TC-004A parameter is outside specification or critical limitCritical parameters produce FAIL; non-critical deviations produce WARNING according to the rule.
TC-007Residual solvent above applicable limitFAIL is produced with solvent name and measured value.

10. QA/QC, CSV and change control

  • Before production use, the client records executable version, checksum, specification/monograph version, test CSV, expected JSON and IQ/OQ results.
  • Column names must not be changed without updating the validator and test scenarios.
  • The source CSV, output.json and utility version should be stored together as an evidence package.
  • Any change in control rules must go through change control and repeated OQ scenario verification.

Included in packages

Neurology QC Suite

QC package for neurology and neuropsychiatry: antiepileptics, antiparkinsonian medicines, antidepressants, antipsychotics, analgesics and neurological diagnostic radiopharmaceuticals.

Open

Vitamins & Minerals QC Suite

Quality-control package for vitamins, minerals, premixes and nutrient substances.

Open