StaffDoseTracker
Staff Dose Tracker
Staff Dose Tracker — Occupational Dose Monitoring (NRB/ICRP)
ℹ️ The utility analyzes individual occupational doses, comparing them with established limits (quarterly and annual) per NRB-99/2009 and ICRP recommendations.
ℹ️ Identifies hazardous trends (consecutive dose increases) and approaching limits.
ℹ️ Processing: only the FIRST record in input.csv file.
⚠️ Critical for radiation safety! Exceeding dose limits leads to legal liability and health risks for staff.
Usage:
StaffDoseTracker.exe → demo mode
StaffDoseTracker.exe input.csv output.json → check data (first record only)
Input format:
EmployeeID,FullName,Category,DoseQuarterMsv,DoseYearMsv,LimitQuarterMsv,LimitYearMsv,ConsecutiveIncreases
Example (Category A, limit 20 mSv/year):
EMP-2026-042,Ivanov I.I.,A,4.8,12.5,5.0,20.0,2
— WHY IS THIS NEEDED?
Radiation Safety Officer must monthly monitor doses of all Group A employees.
• Exceeding quarterly limit (typically 1/4 of annual) requires immediate intervention.
• Accumulation >75% of annual limit requires work schedule revision.
• Dose increase for several consecutive months may indicate procedure violations or shielding failure.
• Automation eliminates risk of missing critical values in paper logs.
⚠️ CRITICAL:
• Annual limit for Group A: 20 mSv (average over 5 years, max 50 mSv in single year).
• Quarterly limit: typically 1/4 of annual (5 mSv).
• Trend: 3 months increase — warning, 5 months — critical situation.
• Category B (staff in supervised area): limits significantly lower (1/10 of Group A).
Critical parameters:
• Usage %: >90% quarter (Warn), >100% (Fail)
• Usage %: >75% year (Warn), >100% (Fail)
• Trend: ≥3 months increase (Warn), ≥5 months (Fail)
⚠️ Note: Utility automatically calculates limit usage percentage and assigns FAIL status on any exceedance. Result includes status and bilingual recommendation (RU/EN).
input.csv
EmployeeID,FullName,Category,DoseQuarterMsv,DoseYearMsv,LimitQuarterMsv,LimitYearMsv,ConsecutiveIncreases EMP-2026-042,Ivanov I.I.,A,4.8,12.5,5.0,20.0,2
URS & FS — user requirements and functional specification
This document defines user requirements and functional specification for the quality-control utility. It supports deployment discussion, IQ/OQ preparation and QC workflow integration.
1. Scope
The Staff Dose Tracker utility is used for Staff Dose Tracker. The actual input.csv is the source of truth for the input structure; control criteria are defined by the executable and the domain description.
The utility does not use machine learning; decisions are produced by deterministic rules.
Categories: Radiation physics
Tags: activity, brachytherapy, dosimetry, source calibration, TG-43
2. Execution modes
StaffDoseTracker.exe → demo mode StaffDoseTracker.exe input.csv output.json → check data (first record only)
3. Key controlled areas
- activity, decay and radiochemical purity
4. Domain limits and critical parameters
- ⚠️ Critical for radiation safety! Exceeding dose limits leads to legal liability and health risks for staff.
- Accumulation >75% of annual limit requires work schedule revision.
- ⚠️ CRITICAL:
- Annual limit for Group A: 20 mSv (average over 5 years, max 50 mSv in single year).
- Quarterly limit: typically 1/4 of annual (5 mSv).
- Trend: 3 months increase — warning, 5 months — critical situation.
- Category B (staff in supervised area): limits significantly lower (1/10 of Group A).
- Critical parameters:
- Usage %: >90% quarter (Warn), >100% (Fail)
- Usage %: >75% year (Warn), >100% (Fail)
- Trend: ≥3 months increase (Warn), ≥5 months (Fail)
- ⚠️ Note: Utility automatically calculates limit usage percentage and assigns FAIL status on any exceedance. Result includes status and bilingual recommendation (RU/EN).
5. URS — user requirements
| ID | Requirement | Criticality | Acceptance criterion |
|---|---|---|---|
| URS-001 | The system shall accept an input.csv file for Staff Dose Tracker with the exact columns listed in the “Input data contract” section. | High | A file with the correct header is processed without manual editing; missing mandatory columns produce FAIL/import error. |
| URS-002 | The system shall support execution without arguments in demo mode and execution with input.csv output.json for user data. | Medium | Both execution scenarios produce a predictable result or clear diagnostic error. |
| URS-003 | The system shall perform rule-based controls for: activity, decay and radiochemical purity. | High | Each controlled parameter receives a status and message; the result does not depend on hidden Excel formulas or ML. |
| URS-004 | The system shall preserve traceability between batch/lot, source values, applied rules and final verdict. | High | Output includes batch identifier, source values, parameter statuses and critical findings. |
| URS-005 | The system shall generate machine-readable output.json for LIMS/ELN/MES, batch record and QA/QC review. | High | JSON contains overall status, check array, warnings, failures and source-file reference. |
| URS-006 | The system shall support use in the client validation package: URS/FS, IQ/OQ preparation, installation and operational scenario checks. | High | The document, test scenarios and reproducible CSV/JSON flow are suitable for audit and internal approval. |
| URS-007 | The system shall clearly separate technical data errors from specification nonconformities. | Medium | Schema/type errors are not mixed with pharmacopoeial deviations and are reported separately. |
6. input.csv data contract
The source of truth for the input schema is the actual input.csv header. Column names are technical identifiers and are not translated.
| # | Column | Type | Unit | Description | Sample | Control rule |
|---|---|---|---|---|---|---|
| 1 | EmployeeID | text | as specified | Employee ID | EMP-2026-042 | mandatory value; format and acceptability are checked by the utility |
| 2 | FullName | text | as specified | Full Name | Ivanov I.I. | mandatory value; format and acceptability are checked by the utility |
| 3 | Category | text | as specified | Category | A | mandatory value; format and acceptability are checked by the utility |
| 4 | DoseQuarterMsv | decimal | as specified | Dose Quarter Msv | 4.8 | mandatory numeric value; rule comparison is performed by the utility |
| 5 | DoseYearMsv | decimal | as specified | Dose Year Msv | 12.5 | mandatory numeric value; rule comparison is performed by the utility |
| 6 | LimitQuarterMsv | decimal | as specified | Limit Quarter Msv | 5.0 | mandatory numeric value; rule comparison is performed by the utility |
| 7 | LimitYearMsv | decimal | as specified | Limit Year Msv | 20.0 | mandatory numeric value; rule comparison is performed by the utility |
| 8 | ConsecutiveIncreases | decimal | as specified | Consecutive Increases | 2 | mandatory numeric value; rule comparison is performed by the utility |
CSV example
EmployeeID,FullName,Category,DoseQuarterMsv,DoseYearMsv,LimitQuarterMsv,LimitYearMsv,ConsecutiveIncreases EMP-2026-042,Ivanov I.I.,A,4.8,12.5,5.0,20.0,2
7. FS — functional specification
| ID | Function | Implementation description |
|---|---|---|
| FS-001 | CLI entry point | The executable StaffDoseTracker.exe supports demo mode and input.csv output.json processing mode. |
| FS-002 | CSV parser | The import module reads CSV, validates header, column presence/order, value count and encoding. Decimal values are expected with a dot separator. |
| FS-003 | Field conversion | Each column is converted to the expected type: identifier, text, decimal number, date/time or boolean flag. |
| FS-004 | Domain rule engine | For Staff Dose Tracker, explicit rules are applied: range, minimum, maximum, absence of prohibited flag, data completeness or calculation-based check. |
| FS-005 | Criticality handling | Critical violations produce FAIL; non-critical deviations and incomplete data produce WARNING; full conformance produces PASS. |
| FS-006 | JSON writer | output.json stores overall status, per-parameter results, source values, warnings, failures and diagnostic messages. |
| FS-007 | Integration contract | The CSV → JSON format is stable for invocation from LIMS/ELN/MES, scheduled task or wrapper service. |
| FS-008 | Error handling | Schema error, missing file, non-numeric value or JSON write failure returns diagnosable error without silent PASS. |
8. output.json contract
The output file must be suitable for automated processing, audit review and correlation with the source input.csv row.
{
"utility": "StaffDoseTracker",
"api": "Staff Dose Tracker",
"batchNumber": "",
"overallStatus": "PASS|WARNING|FAIL",
"checkedAtUtc": "2026-05-18T00:00:00Z",
"checks": [
{
"parameter": "EmployeeID",
"value": "EMP-2026-042",
"unit": "as specified",
"status": "PASS|WARNING|FAIL",
"message": "Rule-based check result"
},
{
"parameter": "FullName",
"value": "Ivanov I.I.",
"unit": "as specified",
"status": "PASS|WARNING|FAIL",
"message": "Rule-based check result"
},
{
"parameter": "Category",
"value": "A",
"unit": "as specified",
"status": "PASS|WARNING|FAIL",
"message": "Rule-based check result"
},
{
"parameter": "DoseQuarterMsv",
"value": "4.8",
"unit": "as specified",
"status": "PASS|WARNING|FAIL",
"message": "Rule-based check result"
},
{
"parameter": "DoseYearMsv",
"value": "12.5",
"unit": "as specified",
"status": "PASS|WARNING|FAIL",
"message": "Rule-based check result"
},
{
"parameter": "LimitQuarterMsv",
"value": "5.0",
"unit": "as specified",
"status": "PASS|WARNING|FAIL",
"message": "Rule-based check result"
},
{
"parameter": "LimitYearMsv",
"value": "20.0",
"unit": "as specified",
"status": "PASS|WARNING|FAIL",
"message": "Rule-based check result"
},
{
"parameter": "ConsecutiveIncreases",
"value": "2",
"unit": "as specified",
"status": "PASS|WARNING|FAIL",
"message": "Rule-based check result"
}
],
"criticalFindings": [],
"sourceFile": "input.csv"
}9. OQ/PQ test scenarios
| ID | Scenario | Expected result |
|---|---|---|
| TC-001 | Valid CSV with expected header and sample row | All rows are processed; output contains PASS/WARNING/FAIL and parameter-level detail. |
| TC-002 | A mandatory input.csv column is missing | Import is rejected or the row receives FAIL with schema reference. |
| TC-003 | A numeric field contains text or a blank value | Type conversion error is recorded; the result is not hidden as PASS. |
| TC-004 | A parameter is outside specification or critical limit | Critical parameters produce FAIL; non-critical deviations produce WARNING according to the rule. |
10. QA/QC, CSV and change control
- Before production use, the client records executable version, checksum, specification/monograph version, test CSV, expected JSON and IQ/OQ results.
- Column names must not be changed without updating the validator and test scenarios.
- The source CSV, output.json and utility version should be stored together as an evidence package.
- Any change in control rules must go through change control and repeated OQ scenario verification.
Included in packages
Ophthalmology QC Suite
QC package for ophthalmology: eye drops, antiglaucoma agents, antibiotics, sterile solutions, osmolality, pH, particles and preservatives.
OpenRadiation Physics QC Suite
Utilities for activity, dosimetry, brachytherapy sources, small-field corrections and TG-43 parameters.
OpenRPH use case: PET scanner state, gamma camera and radiation physics
The linked medical-device/radiation-physics layer: PET detector QC, normalization, AC map, cross-calibration, TOF, gamma-camera uniformity, source strength and staff dose.
OpenRPH workflow: dosimetry and therapy planning
Activity planning, absorbed dose, organ dose, lung shunt, preplanning and therapy verification.
OpenRPH workflow: instruments, devices and radiation safety
PET/gamma-camera state, calibration, detector QC, energy window, TOF, shielding and radiation safety.
OpenRPH workflow: stability, storage, decay and waste
Kinetic stability, shelf life, decay correction, expiry, storage, trend and radioactive waste.
Open